Advertisement

AUTOMATIC ENTRANCE SOLUTIONS
WARNING!
Please start by reading the safety instructions
a
e
BL
CK
DITION
garage door operator
Installation Guide
NRG Automation Range 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLACKEDITION and is the answer not in the manual?

Questions and answers

Robert Weston
March 28, 2025

All 3 led's are flashing and alarm beeping constantly.

1 comments:
Mr. Anderson
March 28, 2025

When all 3 LEDs are flashing and the alarm is beeping constantly on the NRG Automation BLACKEDITION, it likely indicates that the door has been left fully open for more than 10 minutes while the alarm is ON and the auto time close function is OFF. In this state, the alarm sounds and beeps for 30 seconds every 10 minutes until the door is closed.

This answer is automatically generated

Summary of Contents for NRG Automation BLACKEDITION

  • Page 1 AUTOMATIC ENTRANCE SOLUTIONS WARNING! Please start by reading the safety instructions DITION garage door operator Installation Guide NRG Automation Range 2018...
  • Page 2: Table Of Contents

    Contents Contents Page Number Contents..................1 Safety Instructions.................2 Parts List ..................3 Control Board Wiring..............4 Installing the Boom & Operator...........5 Programming Motor Limits & Force Settings......6 Programming Alarm & Auto Time Closing.......7 Programming Reversing Force.............8 Programming 2000 Cycles Maintenance Alarm......9 Programming Transmitters............10 www.nrgautomation.co.uk...
  • Page 3: Safety Instructions

    Please start by reading the safety instructions Before you begin installing the door operator, please read thoroughly these instructions, keep the manual for future reference or pass it on to the subsequent owner of the door. The door operator has been designed for safe use in operation but safety can only be assured if the safety instructions are strictly adhered to during the installation and during use.
  • Page 4: Parts List

    Parts Lists Door Operator Package Boom Package Garage door opener One piece or three piece boom Two transmitters Carrier with cord release Installation manual Motor drive adapter Curved door arm Two slide over brackets (3 piece Two metal fixing bars boom only) Three U brackets Door arm fixing bracket...
  • Page 5: Control Board Wiring

    Control Board Layout • LED light connections: The Nrg Automation 1 mtr light strip (max 14.4w) can be connected to the terminals. 6 (+ 24vdc) & 7 (- 24vdc). The LED will illuminate as a courtesy light and can also be turned on or off using the mode 3 function on the transmitter.
  • Page 6: Installing The Boom & Operator

    Installing the Boom Warning: incorrect installation could lead to severe injury. Before installing the boom and GDO ensure the door is in good working order and correctly balanced. After installation ensure the door automatically reverses when it makes contact with an object placed on the floor at a level of 50mm.
  • Page 7: Programming Motor Limits & Force Settings

    Programming Motor Limits & Force Remove the end programming cap with the NRG Automation label to reveal the programming panel. Programming LED’s Programming the OPEN and CLOSE limits and FORCE learning. Step 1. Open Limit: Press P button for 5 seconds until all 3 LED’s illuminate, then release the P button Then press + button once.
  • Page 8: Programming Alarm & Auto Time Closing

    Programming Auto Closing & Alarm Programming LED’s Automatic Closing (Default off ) Press P button for 5 seconds, LED’s 1, 2& 3 will illuminate. Press + button twice, LED 1& 2 will flash to enter programming mode. Press + or button to select auto close time in accordance with the chart below.
  • Page 9: Programming Reversing Force

    Programming Reversing Force Programming LED’s Force Reverse Programming (default set to level 2) Press P for 5 seconds, LED 1, 2 & 3 will illuminate, courtesy light goes out Press + 4 times, LED 1 & 3 will flash Press + to check the current force setting level. Press + or - to toggle up and down between force level 1 and 2.
  • Page 10: Programming 2000 Cycles Maintenance Alarm

    Programming 2000 Cycles Counter Alarm 2000 Cycles Maintenance Counter - Alarm (Default on) Once the operator has reached 2,000 cycles, the built in alarm will sound and the courtesy light will flash. The alarm and lights will continue to flash until cancelled. This serves as a reminder to the user to carry out the annual maintenance inspection and service.
  • Page 11: Programming Transmitters

    Programming Transmitters...cont’ d Dynamic Mode: - Only 1 button can be programmed this way Hold S button for 2 seconds, LED1 illuminates Press ONCE slowly the top or top left button on the transmitter, LED1 turns off and a beep is heard from the controller. Open Mode: Hold S button for 2 seconds, LED1 illuminates Press S button again, LED 2 illuminates...
  • Page 12 Deleting Transmitters Deleting a single transmitters or ALL transmitters How to delete ALL programmed transmitters Press & hold ‘S’ button for 8 seconds, the illuminated LED 1 turns off. How to delete a SINGLE programmed transmitter Press & hold S and P buttons together, LED’s 3 will turn ON Press any button on the programmed transmitter, LED 3 will turn OFF.
  • Page 13 AUTOMATIC ENTRANCE SOLUTIONS EC DECLARATION OF INCORPORATION Manufacturer / Authorised Representative: NRG Automation Limited, Foundry Lane, Widnes. WA8 8TZ We declare that the product type described below: Black Edition Garage Door Opener are in conformity with the essential requirements of the Machinery Directive 2006/42/EC.
  • Page 14 www.nrgautomation.co.uk AUTOMATIC ENTRANCE SOLUTIONS Garage Door Automation Solutions Single Piece Garage Doors Roller Garage Doors Sectional Garage Doors Radio Controls Smart Phone and GSM Control...