2.5.4 TEMPERATURE PROTECTION

Figure 2-7
shows the circuit diagram for temperature protection.
RT1 is a thermistor located just beneath the IGBT. CN5 is the connector for the thermistor near the pan.
For IGBT temperature protection, there are two kinds of scenarios:
When the temperature rises above 85℃, the set level of output power will automatically downgrade.
When the temperature continues to rise above 90℃, the system will shut down and will remain in that state
until it is restarted manually.
For pan temperature, the system will be shut down when the temperature is over 230℃.
The threshold of protection level can differ, according to the different locations of the thermistor.
Meantime, when the sensed voltage level is close to 5V or 0V, the sensor can be viewed as broken. The whole
system then stops working until it is restarted manually.
+5V
RT1
100K3950
IGBT_T
R5
C4
10K
104
b) IGBT temperature protection
Figure 2-7
Over-Temperature Protection
CN5
PAN_T
2
+5V
1
T_PAN
C25
R29
104
3K
a) Pan temperature protection
2-12