Page 1
Security Level 1. Introduction DA3100 is an on-board diagnostic (OBD-II) device that enables collection of data from vehicle OBD-II port, GPS and Accelerometer. It supports 2G/3G and Bluetooth 4.0 LE (optional) communication with telematics service terminal (TST) servers and smart phones respectively.
Page 2
DA3100 Evaluation Sample User Manual V1.2 Security Level 3.2. DA3100 Operation Steps Step Pre-condition Action Response Remark Ignition On and Plug DA3100 into the vehicle All 3 LEDs will be On for 3 sec. If any LED is off, it indicates that...
Page 3
<USN>: APN user name, blank if not applicable <PWD>: APN password, blank if not applicable <IP>: IP address, eg. 172.22.44.33 (Note: Huawei server IP address) <PORT>: Port number, eg. 12001 (Note: Huawei server port number) <TIME>: upload time in seconds iv.
Page 4
DA3100 Evaluation Sample User Manual V1.2 Security Level 3.4. Web Data View (TST) http://124.238.215.168:8080/TSP-PORTAL/ i. Log on to Username Password Login ii. Enter the following: Username: 88888888888 Password: 11111111 iii. Click on “Road Safety” Click on “Road Safety” 2013-05-30 Huawei Proprietary - Restricted Distribution...
Page 5
DA3100 Evaluation Sample User Manual V1.2 Security Level Screen change to the following: iv. Click on “OBD Display” Click on “OBD Display” 2013-05-30 Huawei Proprietary - Restricted Distribution Page5, Total12...
Page 6
DA3100 Evaluation Sample User Manual V1.2 Security Level v. Select drop list for device serial and select as follows: Drop list vi. Click on the “Detail” to view the other data “Detail” Note: Receive Time is based on the time the server received the data. Server time error could cause this to be inaccurate.
Page 7
DA3100 Evaluation Sample User Manual V1.2 Security Level Detail data as follows: 2013-05-30 Huawei Proprietary - Restricted Distribution Page7, Total12...
Page 8
DA3100 Evaluation Sample User Manual V1.2 Security Level 4. Performance Usage This section allows users to send data message to their server and decode it. The installation and configuration settings are identical as described in section 3.1 and 3.2 respectively.
Page 9
DA3100 Evaluation Sample User Manual V1.2 Security Level Format of message send TST to Device = 【Log In Ack 30 Byte】 【Log In Ack 30 Byte】= 【Total Length 2 byte】【Command Code 2 byte】【Packet Serial Number 4 byte】 【Protocol Version 2 byte】【Safety Mark 1 byte】【Reserved Byte 1 byte】【Device Serial Number 16 byte】...
Page 10
DA3100 Evaluation Sample User Manual V1.2 Security Level ii. Vehicle Data Vehicle data is a one way message where TST just need to decode it and no acknowledge required. Format of message send from Device to TST = 【Header 28 Byte】+【 Message Content 0-65507 Byte】...
Page 11