Hide thumbs Also See for ELITE:

Advertisement

ELITE
INSTALLATION
MANUAL
REV 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELITE and is the answer not in the manual?

Questions and answers

Summary of Contents for Entrotec ELITE

  • Page 1 ELITE INSTALLATION MANUAL REV 9...
  • Page 2 Entrotec regularly develop and enhance product lines, these changes will be included in the latest documentation. Whilst every effort has been made to ensure the accuracy of the information supplied herein, Entrotec is not responsible for any errors or omissions. Many of the images shown are for illustration purpose only. The actual product may vary due to product enhancement or custom configurations.
  • Page 3: Table Of Contents

    Contents Cabling Requirements ............4 BT Wiring Colour Code ............4 Typical Wiring Schematic ............. 5 Overall Schematic ..............6 Typical Installation Layout ............ 7 FS4/FS5/PTE/EPTE Wiring ............. 8 Handset Connections ............9 Video Schematic ..............10 Preset Adjustments............10 Programming the ‘On Board’...
  • Page 4: Cabling Requirements

    Cabling Requirements 1) Between front panel(s) and main control unit. CW1308 - 1 core per flat, 2 core for common and Trades, 1 x 6 pair for LCD + Speaker Amp connections, 0.75mm flex is preferred for 12V DC, 2.5mm Earth. 2) Between lock releases and main control unit.
  • Page 5: Typical Wiring Schematic

    Page 5...
  • Page 6: Overall Schematic

    Door B Power Panel LCD Lock Timer Lock Timer Reassurance to Door Volume PL31 Panel LCD Example of typical Elite controller layout. Fit 1A 0.75mm In-Line Fit 1A Parts and models may vary. Fuse if In-Line 2 AMP 2 AMP...
  • Page 7: Typical Installation Layout

    Typical Installation Layout Note: It is preferable to use 1 x multi-core to the door panel rather than multiple smaller multi-cores (e.g. 3 x Cat5e’s) as using multiple multi-cores can lead to confusion as e.g. 3 x each colour. If using multiple multi-cores then these should be clearly identified at each end.
  • Page 8: Fs4/Fs5/Pte/Epte Wiring

    Brown Wire = 1.5mm (NC Connection). To Lock + Blue Wire To Lock - From System Switched Negative Connection Table: See table below Connection Terminal: Elite Controller PL6/12V Wire A (Brown 1.5mm ) (PL28/12V) PL5/C Wire B (CW1308) (PL33/C) PL5/PE...
  • Page 9: Handset Connections

    Wiring Schematic 7(DS) White/Brown Do Not Wire To EX With Spare Core(s) NOTE - The EX connection is ONLY to be used on Entrotec Extension sounders 4 Pair CW1308 or Cat5e Colour Code and accessories. DO PL10 White/Blue DR (Door Release)
  • Page 10: Video Schematic

    Programming the ‘On Board’ Trades Time-Clock On switch on of the system the screen will display ENTROTEC. Then display the Date, the day of the week, the timer status on line 1. Then time of day, nxon (next on period of timer) and the next on time as example below.
  • Page 11: System Notes

    C). Earth all metalwork connected to the system i.e. Door Panels, fire switches, push to exits etc. D). Whilst Entrotec preset the power supplies to output 13.8v DC to charge batteries it is advisable that these are reset to 13.8v when the system is under full load (with battery disconnected).
  • Page 12 Entrotec Limited Access House 5, Ashwood Court, Oakbank LivingstonvEH53 0TL Tel: 01506 886230 Fax: 01506 886233 Customer Support: 01506 886235 www.entrotec.com Manufactured in the UK...