Table F-1: Supported RFC 1213 Variables (Sheet 2 of 2)
Name
ifInErrors
ifOutOctets
ifOutUcastPkts
ifOutNUcastPkts
Table F-2: Private MIB Parameters (Sheet 1 of 14)
Name
winlink1000OduAdmProductType
winlink1000OduAdmHwRev
winlink1000OduAdmSwRev
winlink1000OduAdmLinkName
winlink1000OduAdmResetCmd
winlink1000OduAdmAddres
winlink1000OduAdmMask
winlink1000OduAdmGateway
winlink1000OduAdmBroadcast
winlink1000OduAdmHostsTable
winlink1000OduAdmHostsEntry
winlink1000OduAdmHostsIndex
winlink1000OduAdmHostsIp
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
OID
.1.3.6.1.2.1.2.2.1.14.x
.1.3.6.1.2.1.2.2.1.16.x
.1.3.6.1.2.1.2.2.1.17.x
.1.3.6.1.2.1.2.2.1.18.x
a. x is the interface ID
MIB Parameters
OID
1.3.6.1.4.1.4458.1000.1.1.1
1.3.6.1.4.1.4458.1000.1.1.2
1.3.6.1.4.1.4458.1000.1.1.3
1.3.6.1.4.1.4458.1000.1.1.4
1.3.6.1.4.1.4458.1000.1.1.5
1.3.6.1.4.1.4458.1000.1.1.6
1.3.6.1.4.1.4458.1000.1.1.7
1.3.6.1.4.1.4458.1000.1.1.8
1.3.6.1.4.1.4458.1000.1.1.10
1.3.6.1.4.1.4458.1000.1.1.12.1.2
Type
Description
Counter
RO
The number of inbound packets that contained
errors preventing them from being deliverable to a
higher-layer protocol.
Counter
RO
The total number of octets transmitted out of the
interface, including framing characters.
Counter
RO
The total number of packets that higher-level
protocols requested be transmitted to a
subnetwork-unicast address, including those that
were discarded or not sent.
Counter
RO
The total number of packets that higher-level
protocols requested be transmitted to a non-
unicast (i.e., a subnetwork-broadcast or
subnetwork-multicast) address, including those
that were discarded or not sent.
Type
Description
DisplayString
RO
ODU configuration description.
DisplayString
RO
ODU Hardware Version.
DisplayString
RO
ODU Software Version.
DisplayString
RW Link Name. A change is effective immediately.
Integer
RW Reset Command. A set command with a value of 3
will cause a device reset. The read value is always
0.
IpAddress
RW ODU IP address. A change is effective after reset.
The parameter is kept for backward compatibility.
Using the alternative parameter:
winlink1000OduAdmIpParamsCnfg is
recommended.
IpAddress
RW ODU Subnet Mask. A change is effective after
reset. The parameter is kept for backward
compatibility. Using the alternative parameter:
winlink1000OduAdmIpParamsCnfg is
recommended.
IpAddress
RW ODU default gateway. A change is effective after
reset. The parameter is kept for backward
compatibility. Using the alternative parameter:
winlink1000OduAdmIpParamsCnfg is
recommended.
Integer
RW This parameter is reserved for the Manager
application provided with the product.
N/A Trap destinations table. Each trap destination is
defined by an IP address and a UDP port. Up to 10
addresses can be configured.
N/A Trap destinations table entry.
RO
Trap destinations table index.
IpAddress
RW Trap destination IP address. A change is effective
immediately.