ASSEMBLY
Gas Control 
Assembly
Air Damper
CONNECTION TO BURNER
  T hread the male-end fitting of the Gas Control Assembly into the 
burner Venturi Tube. Hand-tighten—overtightening will strip the 
threads of the Venturi Tube. 
NOTE: Once connected, the gas control assembly does not need to 
be removed for storage.
USE
LIGHTING THE BURNER
1.    E nsure the regulator is fully closed and turn the air damper until it is 
about halfway open. 
2.    T urn on the gas by twisting the gas cylinder valve counter-
clockwise for one full rotation.
3.    U sing long-handled matches or a lighter, light the burner 
through the ignition hole while slowly opening the regulator.
4.    I f the burner does not ignite, close the regulator and allow 
residual gas to disperse before making a second attempt.
Note: Locate the gas cylinder away from the burner to ensure it is 
not subjected to radiant heat.
CARE
CLEANING
  O nce the burner has cooled, use soapy water with mild detergent 
to wipe down all surfaces. 
NOTE: Do not allow water in burner outlets. Do not submerge the 
burner. Do not use abrasive cleaners or bleach.
Venturi 
Regulator
Tube
CONNECTION TO PROPANE GAS CYLINDER
  –   E nsure the gas cylinder and regulator are fully closed, in the OFF 
position. Attach the regulator-end of the Gas control Assembly to 
the cylinder and tighten.
  –   T urn the gas cylinder counter-clockwise one full turn. Check the 
cylinder for leaks with soapy water. If a leak is detected, shut off 
the gas and re-tighten all connections.
ADJUSTING HEAT OUTPUT
1.    T o increase heat output, turn the regulator counter-clockwise. 
Clockwise rotation will decrease heat output.
2.    U se the regulator and air damper to fine-tune heat output once 
the burner has ignited.
TURNING THE BURNER OFF
  W ith the flame still operating, turn the valve on the gas cylinder 
"OFF". Allow the flame to burn down until all remaining gas in the 
hose has been used. Turn the gas controls on the regulator "OFF"
MAINTENANCE
  –   P eriodically check for leaks using the soapy water method. If any 
signs of weakness are detected on the hose or regulator, replace 
immediately. 
  –   I f the burner flame is unstable, changes color from blue to yellow, 
or has a distinct smell, take the burner to your local appliance-
repair shop immediately for inspection.
Propane Gas Cylinder Valve
Propane Gas Cylinder

Advertisement

loading
Need help?

Need help?

Do you have a question about the DarkStar 2.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Northern Brewer DarkStar 2.0

  • Page 1 Dark Star ® 2.0 is a whole new beast of a burner. Faster full-volume boil. A bigger, better built-in wind guard. Easy to use and loaded with 65,000 BTU’s of brewing power for better beer in a fraction of the time. ASSEMBLY Propane Gas Cylinder Valve Gas Control ...
  • Page 2 TECHNICAL DETAILS Product Dark Star® Burner Output 65,000 BTU Description High Pressure Burner Height of Burner 13.4 inches Size 18 x 18.1 x 13.4 inches Burner Surface Diameter 18 inches Weight (Net weight) 12.5 lbs Pressure Cylinder Pressure WARNING READ AND UNDERSTAND BEFORE USING THIS PRODUCT   –   D o not leave this burner unattended while it is lit or heating.   – Ensure all connections are tightly secured before each use.   –   M onitor  the  burner  when  hot  and  after  use  (temperatures   ...