Inserting Storage Blocks - STIEBEL ELTRON ETS 300 Operation And Installation

Storage heater
Table of Contents

Advertisement

INSTALLATIoN
Installation

10.5 Inserting storage blocks

WARNING Burns
Broken insulation can lead to the casing overheating.
f Check the thermal insulation in the appliance for transport
f
damage.
f Replace faulty thermal insulation.
f
The appliance must be completely free of foreign bodies such as
parts of the packaging.
f Remove the cover panel and cardboard inserts from the inte-
f
rior of the appliance.
The storage blocks are delivered in separate packaging. Storage
blocks with slight transport damage can be used. This does not
impair the function of the appliance.
a
b
c
1 Heating element
2 Storage block
f To insert the storage blocks, raise the heating elements
f
slightly.
f When raising the heating elements, ensure the through
f
holes in the side insulation are not widened by the heating
elements.
f Insert the first storage block, with the heating element cavity
f
pointing upwards, with some clearance to the r.h. thermal
insulation.
www.stiebel-eltron.com
VI.
III.
f Push the storage block up against the r.h. and back thermal
f
insulation. The long holes form the heating ducts.
f Insert the other storage blocks in the order shown.
f
1
2
f Push the cover panel taken from the interior of the appliance
f
over the upper storage blocks.
VII.
IV .
V.
I.
II.
ETS 200-700 |