Electrical features: Maximum voltage: 30 Vdc
An anti-disturbance hardware filter is implemented on the External Trigger
input (< 5 milliseconds delay).
An additional 15 ms (typical) delay can be implemented through a dedicated
software parameter (refer to WinHost Help On Line).

2.3.5 Outputs

The outputs are available only on 25-pin connector models. The following
pins are present on the 25-pin connector of the scanner:
Connector
25-Pin
8
22
11
12
The meaning of the two outputs OUT1 and OUT2 can be defined by the user
(No Read, Right or Wrong). Refer to the Winhost Help On Line.
By default, OUT1 is associated with the No Read event, which activates
when the code signalled by the external trigger is not decoded, and OUT2 is
associated with the Right event, which activates when the code is correctly
decoded.
DS2100 25-pin
11
OUT 2
12
OUT REF
These outputs are both level or pulse configurable.
2.12 - Installation
Maximum current: 25 mA
Name
OUT1+
OUT REF
OUT2+
OUT REF
DS2100 25-pin
and/or
Figure 2.17 Output 1 / Output 2 connections
Function
output 1 +
output reference
output 2 +
output reference
USER INTERFACE
8
OUT 1
22
OUT REF
DATALOGIC
Vext 40 Vdc max