CAME ZT6 Installation Manual

CAME ZT6 Installation Manual

Control panel for 230 v - 400 v gearmotors
Hide thumbs Also See for ZT6:

Advertisement

CONTROL PANEL
319 T 9 0 EN
FOR 230 V - 400 V GEARMOTORS
INSTALLATION MANUAL
ZT6 - ZT6C
EN
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZT6 and is the answer not in the manual?

Questions and answers

Summary of Contents for CAME ZT6

  • Page 1 CONTROL PANEL 319 T 9 0 EN FOR 230 V - 400 V GEARMOTORS INSTALLATION MANUAL ZT6 - ZT6C English...
  • Page 2: Legend Of Symbols

    2 Intended use and limits to use 2.1 Intended use The ZT6 - ZT6C control panel is engineered by Came Cancelli Automatici S.p.A. for commanding 001BK-2200T sliding gates as well as 001C-BXT sectional, sliding and folding door operators. Any installation and use other than that specified in this manual is forbidden.
  • Page 3: Main Components

    4.1 Dimensions ZTC overall dimensions ZT6C case overall dimensions 4.2 Main components Dip-switch selecting features Radio code notifi cation LED light Control panel fuse 630mA F Connecting terminals Accessories fuse 2 A F Transformer connection terminals Line fuse 8 A F 10.
  • Page 4: Installation

    5 Installation 5.1 Preliminary checks Before beginning to install, the following is necessary: • Make sure that the point where the electrical panel is anchored is free from any impacts, and that the surface is solid and that proper tools and materials are used (i.e. screws, wall plugs, etc.). •...
  • Page 5 6 Electrical connections of the ZT6 Gearmotor Tri-phase 400 V AC motor 001BK-2200T 001C-BXT Power supply Terminals for powering the Control panel is 230 24V AC accessories. Overall V AC single-phase allowed power: 45 W powered If the control panel is powered by 230V...
  • Page 6 Lighting and warning devices Cycle/courtesy lamp (Contact capacity: 230 V - 60 W max.) Gate open warning light Contact rated for: 24 V - 3 With dip switch 16 set to OFF and dip switch 17 set W Max.) to ON = Cycle lamp. Indicates that gate is open.
  • Page 7 Safety devices Photocells C1 = Contact (N.C.) for reopening during closing. DIR / DELTA-S Input for safety devices such as photocells, sensitive edges and other devices compliant with the EN 12978 standard. While the operator is closing, the opening of the contact causes the reversal of the direction of movement until completely open.
  • Page 8: Selecting Features

    7 Selecting features 1 ON Automatic closing feature activated; (1OFF - deactivated) 2 ON Open-stop-close-stop with button (2-7) and transmitter (AF card fitted) feature activated 2 OFF Open-closewith (2-7) button and radio transmitter (AF card fitted) feature activated 3 ON Open onlywith transmitter (AF card fitted) feature activated;...
  • Page 9 Fit the AF board only into the gearmotor’s board The transmitter button for opening a gate must be memorized on the gearmotor’s channel CH1 . The transmitter button for opening both gates must be memorized on the gearmotor’s channel CH2 CAME CAME CAME CAME...
  • Page 10: Activating The Radio Command

    10 Activating the radio command Connect the antenna RG58 cable to the terminals and any accessory to connect to the B1-B2 output (N.O. contact) ❶. For the AF43S / AF43SM radiofrequency cards only, position the jumper as shown according to the series of transmitters used ❷. DISCONNECT POWER AND REMOVE THE BATTERIES, IF PRESENT.
  • Page 11: Dismantling And Disposal

    UNI EN ISO 14001 standard to ensure environmental protection. Please help us to safeguard the environment. At CAME we believe this to be one of the fundamentals of our market operations and development strategies. Just follow these short disposal instructions: DISPOSING OF THE PACKAGING The components of the packaging (i.e.
  • Page 12 HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.a. CAME Cancelli Automatici S.p.a. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...

This manual is also suitable for:

Zt6c

Table of Contents

Save PDF