6.00 (2.20 7.30) (KW) CAPACITY 14,330 (3,070 17,060) (B.T.U./h) 20,470 (7,510 24,910) 750(+65) 792(+85) DIMENSIONS (mm) 288(+27.5) 299(+47) NET WEIGHT (Kg) After installation SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT ROOM AIR CONDITIONER OUTDOOR UNIT Hitachi Household Appliances(Wuhu) Co., Ltd.
Page 3
WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS 1. Scope The standards provide for items to be generally observed in carrying and handling semiconductors in relative manufactures during maintenance and handling thereof. (They apply the same to handling of abnormal goods such as rejected goods being returned.) 2.
Page 4
(6) Use a three wire type soldering iron including a grounding wire. Metal plate (of Al. stainless steel, etc.) Bare copper wire (for body earth) Working table Resistor 1MΩ(1/2W) Staple Earth wire Fig.3 Grounding of the working table soldering iron Grounding wire Screw stop at the screwed part using a rag plate...
Page 5
CAUTION In quiet or stop operation, slight flowing noise of refrigerant in the refrigerating cycle is heard occasionally, but this noise is not abnormal for the operation. When it thunders near by, it is recommend to stop the operation and turn off the circuit break er for safety. In the event of power failure,the room air conditioner will restare automatically in the previously selected mode once the power is restored.
SPECIFICATIONS MODEL RAC-35 PC RAC- FAN MOTOR 47W (DC120~380V) FAN MOTOR CAPACITOR FAN MOTOR PROTECTOR COMPRESSOR ASD102SKQ A6 JK6 ATD141RDNA8JT COMPRESSOR MOTOR CAPACITOR OVERLOAD PROTECTOR YES(INTERNAL) OVERHEAT PROTECTOR FUSE (for MICROPROCESSOR) 15A, 2A, 3A, 3.15A 25A, 2A, 3A, 3.15A POWER RELAY G4A-1A POWER SWITCH TEMPORARY SWITCH...
Page 7
Figure showing the installation of Outdoor unit MODEL RAC-35WPC The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle. The difference in height between above 200mm the indoor and outdoor unit should be kept below 10m.
Page 8
Figure showing the installation of Outdoor unit MODEL RAC-50WPC The refrigerating machine oil is easily affected by moisture. Use caution to prevent water from entering the cycle. The difference in height between above 200mm the indoor and outdoor unit should be kept below 10m. above 50 mm when The connecting pipe, no matter installed on the...
CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-35WPC OUTDOOR UNIT Handle Handle Air outlet Air Suction grill Rear side Holes for anchor bolt (2 – ø12 x 6 slots for ø8.0 bolt) Notch for anchor bolt (for 2 – ø8.0 bolt) Drain hole...
Page 10
CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC-50WPC OUTDOOR UNIT Unit : mm Drain hole Drain hole Drain hole More than NOTE: 1.For outdoor unit installation , allow at least 2 sides of space around the unit ensure ventilation flue. 2.The connecting pipe , should all the insulated with insulation pipe. 3.Piping length is within 20m.
GRY : GRAY ORN : ORANGE GRN : GREEN RED : RED BLK : BLACK PNK : PINK VIO : VIOLET MAIN ELECTRIC COMPONENTS FOR OUTDOOR UNIT 15 (mH) 250 m MAX (20 ˚C) RAC-35WPC REACTOR RAC-50WPC 5.3 (mH), 67m (20 ˚C)
Page 12
COMPRESSOR MOTOR Compressor Motor Specifications MODEL RAC-50WPC RAC- 35WPC COMPRESSOR TYPE ASD102SKQ A6 JK6 ATD141RDNA8JT POWER SOURCE 220 - 350 V 220 - 350 V OUTPUT 840W 116 5W WHITE YELLOW 2M= 2.16 7 2M= 1.310 RAC-50WPC RAC-35WP CAUTION When the refrigerating cycle has been operated for a long time with the capillary tubes clogged or crushed or with too little refrigerant, check the color of the refrigerating machine oil inside the compressor.
BLOCK DIAGRAM MODEL RAC-35/50WPC Power source OUTDOOR UNIT Compressor Power circuit drive circuit Indoor unit Compressor Indoor / Outdoor motor interface circuit Control power circuit Outdoor DC fan motor Reset circuit drive circuit Outdoor Fan motor Overheat thermistor Defrost thermistor Reversing valve drive circuit Outdoor temperature...
Page 17
MODEL RAC-35WPC COOLING CYCLE OUTDOOR UNIT Indoor unit Silencer Silencer HEATING CYCLE OUTDOOR UNIT Indoor unit Silencer Silencer...
Page 18
MODEL RAC-50WPC COOLING CYCLE OUTDOOR UNIT Silencer 1/2 Silencer Indoor unit Silencer Silencer 1/4 HEATING CYCLE OUTDOOR UNIT Silencer 1/2 Silencer Indoor unit Silencer Silencer 1/4...
Procedure for Disassembly and Reassembly OUTDOOR UNIT MODEL RAC-50WP OUTDOOR UNIT MODEL RAC-35WPC 1. Electrical parts 1. Electrical parts (1)Remove the service value cover lock screws (1)Remove the service value cover lock screws and lower the cover to remove it.
DESCRIPTION OF MAIN CIRCUIT OPERATION RAC-35WPC 300-330 Main parts C021-C022,37 5 ,420V)
Page 21
2. Power circuit (Low voltage) Fig. 2-1 The 230V AC voltage is rectified to DC voltage (B-12V,16V,12V,5V) pass through switching control IC (ICI), switching transformer. (1) B-12V Power supply for electrical expansion valve. (2) 16V Power supply for IPM driver circuit of compressor and fan motor, IGBT action. (3) 12V Power supply for 4 way valve relay, power relay, inrush current relay,motor current amplification, (4) 5V...
Page 23
4.Reversing valve control circuit This model reversing valve control used to control the relay ON/OFF of the revesing valve, and also control the coil of the reversing valve ON/OFF. The relay ON/OFF has different type when in the different operation mode. You can see each operation mode as fllows.
Page 29
C021-C023,500 ,450V) 33 ACT R249 IP CUT 300-330...
Page 30
2. Power circuit (Low voltage) Fig. 2-1 The 230V AC voltage is rectified to DC voltage (B-12V,16V,12V,5V) pass through switching control IC (ICI), switching transformer. (1) B-12V Power supply for electrical expansion valve. (2) 16V Power supply for IPM driver circuit of compressor and fan motor, IGBT action. (3) 12V Power supply for 4 way valve relay, power relay, inrush current relay,motor current amplification, (4) 5V...
Page 32
4.Reversing valve control circuit This model reversing valve control used to control the relay ON/OFF of the revesing valve, and also control the coil of the reversing valve ON/OFF. The relay ON/OFF has different type when in the different operation mode. You can see each operation mode as fllows.
SERVICE CALL Q&A Cooling operation The compressor sometimes Cooling when the room Check if the heat stops during cooling. temperature is low may exchanger of the indoor cause the heat exchanger unit is covered with dew. of the indoor unit to gather Wait for 3 to 4 minutes dew.
Page 38
Common, etc. In "automatic wind speed" mode, the In wind speed "automatic" mode, This does not abnormal. It indoor fan changes from strong wind the product will sense the heat is because the cold wind to weak wind to slight wind. exchange temperature and, prevention is working.
Wireless remote control The timer will not become set. Have you set the product to the current time? The timer cannot be set unless it is set to the current time. The current time When set to the current The current time display will disappears 10 seconds time setting, the reading disappear at once.
Page 40
This occurs when the room temperature and humidity I set the "sleep" timer during have reached their settings during dehumidification and operation.But the air-conditioner is in a pause. The product will begin the indoor fan will not run (it will again to run within about 3 minutes.
TROUBLE SHOOTING MODEL RAC-35/50WPC Inspection instructions RAC-35WPC RAC-50WPC Indoor fan motor Indoor fan motor Power supply Power supply Indoor Electrical Outdoor Electrical Indoor Electrical Outdoor Electrical 1Φ 230V 50Hz 1Φ 230V 50Hz Compressor Compressor motor motor Warning 0V line 0V line...
Page 42
P.W.B. as shown in the figure below, in order to discharge voltage in smoothing capacitor. Do not use a soldering iron with transformer: Otherwise, thermal fuse inside transformer will be blown. RAC-35WPC LEAD WIRE SOLDERING IRON (30 TO 75W) RAC-50WPC MAIN P.W.B.
Page 43
Other instructions (1) Detaching and reattaching the receptacles for tab terminal All the receptacles for connecting tab terminals are with a locking mechanism. Forcibly pulling any such receptacle without unlocking it will destroy it. Be on guard. When reconnecting it, insert it securely all the way home. ・Receptacle types and how to unlock them Mild resin cover Cancel button...
Page 44
Troubleshooting support Function ・The failure mode detected on the outdoor unit side is displayed by blinking the "LD301". Detecting a failure will stop the outdoor unit [Display on the and keep blinking the LD301 until it is restarted. outdoor unit side] (The communication error will persist until the communication is reestablished.) ・The failure modes detected on the indoor and outdoor unit sides...
Page 45
SELF-DIAGNOSIS LIGHTING MODE MODEL RAC-35WP C...
Page 46
SELF-DIAGNOSIS LIGHTING MODE MODEL RAC-50WP C...
Page 47
After turning on the power, perform air purification by remote control. Is there 230V AC between Is the LD301 turned on? Ensure the power supply. terminal boards L and N? Breaker activated Normal Check for electrical leakage. After that, Has the breaker not been activated? turn on the breaker and make a double -check.
Page 48
* This page is for RAC-35WPC Check the blinking frequency of the LD301. The LD301 blinks 13 times. Replace the outdoor electrical parts (in the case of an abnormality in the EEPROM reading error microcomputer or EEPROM). Abnormal The LD301 blinks 9 times.
Page 49
Check the blinking frequency of the LD301. * This page is only for RAC-50WPC The LD301 blinks 13 times. Replace the outdoor electrical parts (in the case of an abnormality in the EEPROM reading error microcomputer or EEPROM). Abnormal The LD301 blinks 9 times. Check the F cable connection (for half insertion, connection by Correct the F cable connection.
Page 50
The LD301 blinks 10 times. AC 187 V or less, AC 253 V or more Is there AC 220 -230V between Check the power supply. terminal boards L and N? Power supply voltage error AC 187-253 V Ifyon confirm the connect of the reactor Abnormal Is there a voltage of DC 264-358 V ? wire, And it is ok, please change the...
Page 51
When cooling: Is the heat exchanger of the outdoor unit clogged up? Is there shelter around? The LD301 blinks 5 times. When heating: Is the heat exchanger or filter of the indoor unit Since the compressor Clear up the causation load was heavy, the clogged up? Overload lower limit cut...
Page 52
Abnormal The creepage breaker have already set? The LD301 blinks 14 times Change the compressor and then Does the compressor insulation OK? check the outdoor ele. unit . Active voltage abnormal Normal Change the outdoor ele. unit. Q601,Q602 (RAC-50WPB only) have malfunction Change the outdoor ele.
Page 53
(JUDGING BETWEEN GAS LEAKAGE AND CHECKING THE REFRIGERATING CYCLE COMPRESSOR DEFECTIVE) 1. Troubleshooting procedure (No operation, No heating, No cooling) Lighting mode Blinks Blinks Blinks Blinks Blinks Blinks Connect U,V,W phase leads to the Self- 2 times 3 times 4 times 5 times 6 times 8times...
Page 54
In this case, turn the power off and start the procedure from 1 again.) ※(For the initialization of the expansion valve, it may take 1 min until the operation starts.) 4. When you press the test switch again for 1 sec or longer, the unit stops the operation. RAC-35WPC RAC-50WPC...
6. When the operation with the test switch is over, turn off the breaker and set the connectors back. HOW TO OPERATE THE OUTDOOR UNIT INDEPENDENTLY RAC-35WPC 1. Connect the large dia. pipe side and small dia. pipe side service valve using a pipe.