Electrical Specifications - Huawei GAQ40S3V3B Technical Manual

Dc-dc converter
Table of Contents

Advertisement

GAQ40S3V3B
DC-DC Converter Technical Manual V1.4

Electrical Specifications

Conditions: T
= 25°C (77°F), Airflow = 1 m/s (200 LFM), V
A
Parameter
Absolute maximum ratings
Input voltage
Continuous
Transient (100 ms)
Operating ambient
temperature
Storage temperature
Operating humidity
Input characteristics
Operating input voltage
Maximum input current
No-load loss
Input capacitance
Inrush transient
Input reflected ripple current
(peak to peak)
Output characteristics
Output voltage set point
Output power
Output line regulation
Output load regulation
Regulated voltage precision
Temperature coefficient
External capacitance
Output current
Output ripple and noise
(peak to peak)
Output voltage Trim range
Output voltage overshoot
Output voltage rise time
Switching frequency
GLOBAL ENERGY EFFICIENCY SPECIALIST
Min.
Typ.
Max.
-
-
80
-
-
100
-40
-
85
-55
-
125
5
-
95
36
48
75
-
-
4.5
-
3.6
-
47
100
-
-
-
1
-
-
20
3.25
3.3
3.35
0
-
132
±0.20
-
-
±0.30
-
-
±3
-
-
-
-
0.02
4
470
-
10
0
-
40
-
80
120
80
-
110
-
-
5
-
5
20
-
310
-
= 48 V, unless otherwise notes.
in
Units
Notes & Conditions
V
-
-
V
º C
See the thermal derating curve
º C
-
% RH
Non-condensing
V
-
A
V
= 36 V; I
in
out
W
V
= 48 V; I
in
out
µF
Aluminum electrolytic capacitor
A² s
-
mA
Oscilloscope bandwidth: 20 MHz
V
V
= 36 - 75 V; I
in
W
-
%
V
= 36 - 75 V; I
in
%
V
= 48 V; I
in
out
%
V
= 36 - 75 V; I
in
%V
/°C
T
= -40°C to +85°C (-40°F to +185°F )
out
A
µF
-
A
-
mV
Oscilloscope bandwidth: 20 MHz
%
-
%
The whole range of V
ms
The whole range of V
kHz
-
3
= 40 A
= 0 A
= 40 A
out
= 40 A
out
= 0 - 40 A
= 0 - 40 A
out
, I
and T
in
out
A
, I
and T
in
out
A

Advertisement

Table of Contents
loading

Table of Contents