Over Temperature Failure
◦
Input Voltage Lost
◦
Fan Failure
◦
High Input A/C Warning
◦
Low Input A/C Warning
◦
High Output Warning
◦
Low Output Warning
◦
Inlet Temperature Warning
◦
Internal Temperature Warning
◦
High Vaux Warning
◦
Low Vaux Warning
◦
Mismatched Power Supplies
◦
•
Hotplug—Whether the power supply bay supports swapping the power supply when the
server is powered on. If the value is Yes, and the power supplies are redundant, the power
supply can be removed or replaced when the server is powered on.
•
Model—The power supply model number.
•
Spare—The spare power supply part number.
•
Serial Number—The power supply serial number.
•
Capacity—The power supply capacity (watts).
•
Firmware—The installed power supply firmware version.
Smart Storage Battery details
The following details are displayed on servers that support the Smart Storage Battery.
•
Index—The battery index number.
•
Present—Whether a battery is installed. The possible values are OK and Not Installed.
•
Status—The battery status. The possible values are OK, Degraded, Failed, or Other.
•
Model—The battery model number.
•
Spare—The part number of the spare battery.
•
Serial Number—The battery serial number.
•
Capacity—The battery capacity.
•
Firmware—The installed battery firmware version.
Power monitoring
iLO monitors the power supplies in the server to ensure the longest available uptime of the
server and operating system. Brownouts and other electrical conditions might affect power
supplies, or AC cords might be unplugged accidentally. These conditions result in a loss of
redundancy if redundant power supplies are configured, or result in a loss of operation if
redundant power supplies are not used. If a power supply hardware failure is detected or the AC
power cord is disconnected, events are recorded in the IML and LED indicators are used.