TROUBLESHOOTING

Although rare, you may see an error message display on your control panel. Please refer to the following chart
for potential issues and how to resolve them:
CODE
ERROR
LEr
Low temperature
HEr
High temperature
Er1
Bad probe
Er2
Thermocouple
disconnected
Er3
Failed to ignite
Er4
Fan disconnected
Er5
Igniter disconnected
Er6
Auger disconnected
Er7
Auger jammed
3643 Ranger UCGv02.indd 21
(cont.)
SOLUTION
This will occur if the temperature of the grill falls below 120°F (49°C) for 10
minutes, causing the grill to go into shutdown mode. To fix, remove any
pellets from the firepot. Turn the controller off and then on again and restart
your grill. If the problem persists, call customer service.
This error will occur when the temperature in the grill reaches temperatures
above 550°F (288°C) for more than 45 seconds. Let the grill cool, then turn off
the grill. Clear out any remaining pellets from the firepot and restart your grill.
If the problem persists, call customer service.
Your probe will need to be replaced.
Check the connection underneath the hopper for the thermocouple. If it is
tight, your thermocouple will need to be replaced.
Check the connection of the hot rod. If the connection is good, then the hot
rod will most likely need to be replaced
Check the connection of the fan. If the connection is good, then the fan will
most likely need to be replaced.
Check the connection of the hot rod. If the connection is good, then the hot
rod will most likely need to be replaced.
Check the connection for the auger. If the connection is good, then auger
motor will most likely need to be replaced.
With the grill in Idle mode, press and hold the DOWN and IGNITE buttons at
the same time. The display will flash "Clr" and the auger will cycle between
moving forwards and backwards for 60 seconds to clear the jam.
To stop the sequence before it is complete, press and hold the DOWN and
IGNITE buttons at the same time.
CAUTION!
Be careful not to burn yourself. If this
does not put out the fire, carefully remove the
food from the grill and keep the lid closed until
the fire is completely out. Again, be careful not to
burn yourself. When the grill is completely cool,
remove all internal components. Clean any grease
accumulation from the TGMS. Replace the grease
drip tray and grill grates, restart the grill, and
resume cooking.