Eradicator II AIF
Eradicator II AIF Systems
Installation, Operation,and
Maintenance Manual
Air Induction Filter Systems
Installation, Operation,
and Maintenance Manual
114 Vista Parkway
Avon, IN 46123
(317) 272-6721 • (800) 272-5511
© 2014 New Aqua LLC
1
Patent # 7,300,569
© 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eradicator II AIF and is the answer not in the manual?

Questions and answers

Robert Rowan
March 5, 2025

I have had unit for 12 years. Does the mixed media need replacement at some point?

Summary of Contents for Aqua Systems Eradicator II AIF

  • Page 1 Maintenance Manual 114 Vista Parkway Avon, IN 46123 (317) 272-6721 • (800) 272-5511 © 2014 New Aqua LLC Patent # 7,300,569 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 2: Owner Information

    AIF systems to be done by a trained technician. Aqua Systems recommends that AIF systems be installed by a trained technician. There are many issues involved in suc- cessfully treating problem water that go beyond putting the pipes together. This manual is written for the owner. It covers the basic installation requirements and the simple settings that an owner will need to know.
  • Page 3: Table Of Contents

    Refill Flow Control Assembly or Refill Port Plug ......................31 Water Meter or Meter Plug ..............................32 Bypass Valve..................................32 Troubleshooting ........................... 34-36 Notes..............................37 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 4: How The Eradicator Works

    Treatment Cycle Regeneration Cycle - Air is inducted to system Initiated after reaching before returning to the prescribed service treatment cycle volume © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 5 Air is a powerful oxidizer for both iron and sulfur. Historically, air has been utilized in water treatment through aeration tow- ers, injection of compressed air, or by using an inline venturi. Aqua Systems AIF technology is a breakthrough because air is introduced through an induction venturi that is built into the control valve.
  • Page 6: Pre Install Review

    Swimming Pool Fill Line ________ Inlet Water Line Size ______ Kitchen Cold _________________ No. in Family _______ Irrigation Systems_____________ No. Baths _________ © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 7: Pre Assembly

    Heat from soldering or PVC glue solvents 1” PVC Male shown may damage the nut, split ring, or o-ring and fittings. figure 2 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 8: Bypass Operation

    (i.e. a plumbing con- nection somewhere in the building bypasses the system). (see figure 4) figure 3 figure 4 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 9: Installation

    If there is a three way bypass in the existing plumbing, inspect it to make sure the bypass valve shuts off 100% when closed. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 10 You must test the drain line security before leaving any installation site. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 11: Installation

    12' of pipe between softener and heater 3 Valve Bypass Optional Water Heater Well Line In Pressure Tank AIF System SmartChoice Water Conditioner © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 12: Start Up

    Water from the AIF system will always have effervescence to it because of the air in the treatment process. However, it is much more significant in the first 90 days. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 13: Programming

    Salt Monitoring, Service Alarm and Error Screens will activate the Display light, and keep it on until the Alert condition is cleared. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 14 Display backlight will turn on with the activation of any User Alter Screen. *This is the default setting* © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 15 To initiate a regeneration at the normal scheculed time, push and release the “REGEN” button. The display will alternate from the current screen to “REGEN TODAY”. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 16: Service

    Normal Threads - Facing the unit from the Clip front, loosen the base nut by turning from left to right. figure 1 figure 2 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 17 3 Turn on water and make sure there are no leaks before continuing return to service. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 18: Parts Diagrams

    02910182 Tank Adapter (items 1 & 4) 02910183 Tank Nut 02910184 Split Ring 02910126 O-Ring 215 02910188 O-Ring 231 02910166 O-Ring 337 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 19 (2 - 6) 02910106 Drive Assy (includes parts 2 - 6) Not Shown 02910302 Clear Display Cover Not Shown 02910166 Transformer 110v - 12v © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 20 Qty. 02910111 Spacer Stack Assy 02910110 Drive Cap Assy 02910141 O-Ring 228 02910124 Piston Downflow Assy 02910160 Regenerate Piston 02910166 O-Ring 337 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 21 Injector Assy J Light Blue 02910122 Injector Assy K Light Green Not Shown 02910158 O-Ring 11 (Injector) Not Shown 02910159 O-Ring 13 (Injector) © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 22 Elbow Locking Clip 03310738 Polytube Insert 3/8" 03310732 Nut 3/8" 03310740 Elbow Cap 02910154 O-Ring 019 Not Shown 09470053 OF15 DN15 Check Valve © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 23   Water Flow Proper Drain Line Flow Control orientation directs water flow towards the washer face with rounded edge and text. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 24 02910148 Nut 1" QC 02910108 Meter Assy 02910140 Turbine Assy 02910126 O-Ring 215 02910109 Meter Plug Assy      © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 25 Complete PVC Male Kit 02950003 Complete PVC Solvent Kit                 © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 26 O-Ring 214                     © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 27 Shown 02950123 Valve Wrench                   © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 28: Service Guide

    Replace broken or damaged drive gears. Do not lubricate any of the gears. Avoid getting any foreign matter on the © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 29: Drive Cap Assembly, Main Piston And Regenerant Piston

    Chemically clean in dilute sodium bisulfite or vinegar or replace the main piston. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 30: Spacer Stack Assembly

    (e.g. 154) and then reset the valve to the service posi- tion. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 31: Injector Cap, Screen, Injector Plug And Injector

    A silicon lubricant may be used on the o-ring on the elbow or the white may be used on the o-ring on the retainer. elbow or the white retainer. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 32: Water Meter Or Meter Plug

    There are three o-rings: one under the rotor cap, one on the rotor stem and the rotor seal. Replace worn o-rings. Clean rotor. Reinstall rotor. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 33 The display should flash all wording, then flash the software version (e.g. 154) and then reset the valve to the service position. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 34: Troubleshooting

    Replace PC board i. PC board incorrectly aligned to drive i. Ensure PC board is correctly snapped on to bracket drive bracket © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 35 9. Time of day flashes on REGEN buttons were pressed to b. Reset the time of day and off reset the control. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 36: Troubleshooting

    Water for these purposes should be treated separately. Using an AIF for any of these, or similar, uses will result in poor performance, and damage to the system. © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 37: Notes

    Eradicator II AIF Systems Installation, Operation,and Maintenance Manual Notes Installation, Operation, and Maintenance Manual © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 38: New Aqua Llc Dba Aqua Systems • 7785 East Us Hwy 36 • Avon, In

    Eradicator II AIF Systems Installation, Operation,and Maintenance Manual © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 39 Eradicator II AIF Systems Installation, Operation,and Maintenance Manual © 2014 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 40 © 2014 New Aqua LLC 2/2014 Rev. 1...