Download Print this page
Roscoe Medical Select Combo II Quick Reference Manual
Roscoe Medical Select Combo II Quick Reference Manual

Roscoe Medical Select Combo II Quick Reference Manual

Advertisement

Quick Links

QUICK REFERENCE GUIDE – SELECT COMBO II
1
Waveform Mode
LCD DISPLAY
2
Home Screen
3
Set Mode
1
4
Output: Start, Pause or Lock
2
5
Channel 1 intensity level
3
6
Compliance Meter (hours)
4
7
Output Intensity of Channel 1
5
8
Body Part Selection
6
9
Treatment Time (minutes)
7
10
Low-Battery Indicator
11
Load Indicator
12
Compliance Meter Mode
Never remove the self-adhesive electrodes from the
skin while the device is turned on!
IMPORTANT!
WARNING: Device will not work while charging. Device is
partially charged upon receipt.
firmly on the skin or the device has not connected with the lead
wires securely, and the output intensity level is equal or greater
than 10mA, the intensity will stop automatically.
1
INSERT BATTERY
Press down on the belt clip to
release it. Remove the battery cover
and insert the battery as shown in
the diagram. Replace the battery
cover and belt clip.
2
CONNECT LEAD WIRES
Make sure the device is completely
turned OFF. Take the pads out of the
sealed package; insert the lead wire
pin into the electrode pigtail. Make
sure no bare metal is exposed.
Insert the lead wires into the
output sockets located at the top
of the device.
Note: If only using one channel, only
plug in 1 lead wire.
QUICK REFERENCE GUIDE – SELECT COMBO II
PAGE 2
3
TURNING THE DEVICE ON OR OFF
12
Select Combo II
11
10
9
M /
S
8
4
SELECT THERAPEUTIC BODY PART
5
SETTING THE MANUAL PROGRAM — U1
If the electrodes are not placed
6
TENS — SET PULSE RATE
7
TENS — PULSE WIDTH & START TIME
PAGE 3
Press the [
] button to turn the device "ON" or "OFF".
If there is an immediate need to pause treatment,
press the [ M/II ] button to pause treatment.
Press it again to continue treatment or press [
]
to stop treatment and go back to the home screen.
There are 6 therapeutic body part buttons available:
neck, shoulder, hand, low back, knee and foot. Each
therapeutic part has 3 programs – P1, P2 and U1.
Total of 72 programs.
Select Treatment Mode & Body Part
Press [ M/II ] button to select the TENS/NMES/IF or
RUSS treatment mode. Select the body part which
you want to treat. Then press the body part button
until the LCD displays program "U1" like the first
screen on the left.
Set Treatment Time
Press [ S ] button to enter treatment time and the
"min. " will flash. Press [ + ] or [
] button to adjust
the treatment time.
Set Pulse Rate
Press [ S ] button to enter the pulse rate and
the "Hz" will flash. Press [ + ] or [
] button to
adjust pulse rate.
Pulse Width
Press [ S ] button to enter the pulse width and the
"µs" will flash. Press [ + ] or [
] button to adjust the
pulse width.
Start Treatment
Press [CH1+] or [CH2+] to increase the output
intensity of channel 1 and/or channel 2. Press
[CH1−] or [CH2−] to decrease the output
intensity of channel 1 and/or channel 2.
When done, press [ S ] or [
] to confirm and return
to the home screen.
QUICK REFERENCE GUIDE – SELECT COMBO II
8
TENS — SET PRESET PROGRAMS — P1 & P2
Select Treatment Mode
Press [ M/II ] button to select the TENS treatment
mode. Select the body part which you want to
treat. Press the body part button until the LCD
displays program "P1" or "P2" like the screen
on the left.
To set your treatment time refer back to Step 5.
To start your treatment refer back to Step 7.
9
NMES — SETTING THE MANUAL PROGRAM — U1
To set your NMES Manual Program refer back to Step 5,
then return to Step 10.
10
NMES — SET PULSE WIDTH & PULSE RATE
Set Pulse Rate
Press [ S ] button to enter the pulse rate and
the "Hz" will flash. Press [ + ] or [
adjust pulse rate.
Pulse Width
Press [ S ] button to enter the pulse width and the
"µs" will flash. Press [ + ] or [
pulse width.
11
NMES — SET RAMP UP TIME
Set Ramp Up/Down Time
Press [ S ] button to set the ramp up and down
time and the "sec. " will flash and you will see
the image circled in red on the screen to the left.
Press [ + ] or [
] adjust the treatment time.
12
NMES — SET CONTRACTION TIME
Set Contraction Time
Press [ S ] button to set the contraction time
and the "sec. " will flash along with the symbol
circled in red to the left. Then press [ + ] or [
button to adjust the time.
13
NMES — SET RELAXATION TIME
Set Relaxation Time
Press [ S ] button again to set the relaxation time and
the "sec. " will flash along with the symbol circled in
red to the left. Then press [ + ] or [
the time.
After you finished settings, press [ S ] or [
to confirm, the device will back to standby status.
To set your treatment time refer back to Step 5.
To start your treatment refer back to Step 7.
PAGE 4
] button to
] button to adjust the
]
] button to adjust
] button

Advertisement

loading
Need help?

Need help?

Do you have a question about the Select Combo II and is the answer not in the manual?

Questions and answers

Summary of Contents for Roscoe Medical Select Combo II

  • Page 1 QUICK REFERENCE GUIDE – SELECT COMBO II QUICK REFERENCE GUIDE – SELECT COMBO II QUICK REFERENCE GUIDE – SELECT COMBO II PAGE 2 PAGE 3 PAGE 4 Waveform Mode TURNING THE DEVICE ON OR OFF TENS — SET PRESET PROGRAMS — P1 & P2...
  • Page 2 The purpose of this guide is to assist you in correctly operating your InTENSity™ treat. Press the body part button until the LCD Select Combo II TENS/NMES/IF/RUSS (DI2195) unit. This device should only be displays program “P1” or “P2” like the screen RUSS —...