Timer Adjustment - Timer Models only
Isolate the power supply. The timer is factory set at midpoint. Time is set by placing the black bridge
over 2 of the pins on the right hand side of the timer board. If bridge is not fitted, timer will default to 20
minute setting. Replace front cover BEFORE switching on the power supply.
30 Mins
HUMIDITY ADJUSTMENT - HUMIDITY MODELS ONLY
Isolate the power supply. Remove the front cover. The humidity control adjustment position is clearly
marked. Turn clockwise for less sensitivity and anti-clockwise for greater sensitivity. Turn fully clockwise
to turn the humidity sensor off. Replace front cover BEFORE switching on the fan.
SDF 100 RANGE
SDF100B Standard SDF100PB
With Pull Cord
With
With Humidistat
SDF100TB
SDF100HTB
Timer
and Timer
SDF 150 RANGE
SDF150B Standard SDF150PB
With Pull Cord
With
With Humidistat
SDF150TB
SDF150HTB
Timer
and Timer
Twin Speed with
SDF150 HTBTW
Humidistat and Pull Cord
CLEANING
Disconnect power supply before cleaning.
It is important to clean fans regularly as cleaning helps maintain performance and ensure safe, reliable operation.
The front cover can be removed from the fan and gently washed in warm water, dry throughly.
The interior of the fan can be dusted with a soft brush. Do not use water.
On humidity control models, please ensure that no water enters the sensor grille.
230V ac - 50Hz
12W (SDF100) 35W (SDF150)
IPX4 Rating – This product is double insulated.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
V E N T I L A T I O N
Domus Ventilation
Cambria House, Caerphilly Business Park, Van Road, Caerphilly
CF83 3ED
Tel: +44 (0)3443 715523
Fax: +44 (0)3443 715524
Email: vent.info@domusventilation.co.uk
www.domusventilation.co.uk
15 Mins
5 Mins
SDF100HTBPC With Humidistat, Timer
and Pull Cord
With Movement
SDF100PIR
Detector and Timer
With Humidistat,
SDF150HTBPC
and Pull Cord
Twin Speed
SDF150PBTW
and Pull Cord

Installation Instructions

ISSUE C
LAB038R
V E N T I L A T I O N
SDF100/150
Axial Wall Fans

Advertisement

loading
Need help?

Need help?

Do you have a question about the SDF100 and is the answer not in the manual?

Questions and answers

Summary of Contents for DOMUS Ventillation SDF100

  • Page 1: Installation Instructions

    On humidity control models, please ensure that no water enters the sensor grille. 230V ac - 50Hz 12W (SDF100) 35W (SDF150) IPX4 Rating – This product is double insulated. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental...
  • Page 2 WIRING INSTRUCTIONS SDF 100/150 It is recommended that the fans be connected into the lighting circuit, with double pole Window / Wall Fan (3mm) isolation provided before the room light switch and suitably fused, in accordance These high quality extractor fans are designed to provide effective ventilation and in order with current IEE Regulations.