Chapter 11 SONET
11.6.14
SONet:APS:RX Pt :K1
Syntax
SONet:APS:RX Pt :K1
Description
This command sets the destination node/source channel (K1).
Parameters
Pt
value
MINimum=0, MAXimum=15, DEFault = 0
Response
None.
Example
SON:APS:RX1:K1 3
Notes
Cannot be changed if the SONet:APS:CONFig command is set to LIN, 1P1.
Changes to SONet:APS:CONFig will reset this value to 0.
Syntax
SONet:APS:RX Pt :K1?
Description
This query returns the destination node/source channel (K1).
Parameter
Pt
Response
value
Example
SON:APS:RX1:K1?
Note
11.6.15
SONet:APS:RX Pt :K2
Syntax
SONet:APS:RX Pt :K2
Description
This command sets the source node/bridged channel (K2).
Parameters
Pt
value
MINimum=0, MAXimum=15, DEFault = 0
Response
None.
Example
SON:APS:RX1:K2 3
Notes
Cannot be changed if the SONet:APS:CONFig command is set to LIN, 1P1.
Changes to SONet:APS:CONFig will reset this value to 0.
Syntax
SONet:APS:RX Pt :K2?
Description
This query returns the source node/bridged channel (K2).
Parameter
Pt
Response
value
Example
SON:APS:RX1:K2?
Note
11.6.16
SONet:APS:RX Pt :APPLy
Syntax
SONet:APS:RX Pt :APPLy
Description
This command applies the K1/K2 request setup to the transmitter.
Parameter
Pt
Response
None.
Example
SON:APS:RX1:APPL
Notes
11.7
Tributary Scan
11.7.1
SONet:TSCan:STARt
Syntax
SONet:TSCan:STARt
Description
This command starts the tributary scan test.
Parameter
None.
Response
None.
Example
SON:TSC:STAR
Note
It is possible to run only one test or measurement at a time. The SONET interface must be
active for at least one of the receivers.
372
value
= Port number
=
NUMERIC PROGRAM DATA
= Port number
=
NR1 NUMERIC RESPONSE DATA
3
value
= Port number
=
NUMERIC PROGRAM DATA
= Port number
=
NR1 NUMERIC RESPONSE DATA
3
= Port number