EXITGUARD User Instructions
Power LED
exitguard
Setup LED
Off
I I
II II
Mode LEDs
I
Chime mode
1
2
II
Keypad reset mode
4
5
III
7
8
Auto re-arm mode
Keypad
These user instructions apply to EX204, EX205 and EX206
versions of the EXITGUARD. For details on setting various
functions refer to Installation Instruction 60086. available on
our website www.hoyles.com.
When your EXITGUARD has been installed and set up you
will have been given a 4 digit USER CODE. Make a note of
the number in the box above, you will need this number to
switch to any of the various modes or to silence the
EXITGUARD if it is sounding.
There are four possible user modes
1.OFF. The protected door can be opened without sounding
the alarm.
2.CHIME. When a door opens the EXITGUARD will sound
a short chime, like a shop door bell.
3.KEYPAD RESET.
When the door opens the
EXITGUARD sounds until the user code is entered.
4.AUTO RE-ARM. When the door opens the EXITGUARD
sounds and resets a short time after the door is closed (This
time delay is usually set to
seconds
You can interrogate the mode status at any time: Simply
type in the User Code, one of the 4 Mode LED will illuminate
for a period of 5 seconds.
1. To use Chime Mode enter the USER CODE to
interrogate the EXITGUARD and enter 1 before any mode
LEDs extinguish. The Chime LED illuminates for about 5
seconds. When it extinguishes the EXITGUARD is set to
Chime Mode.
2. To use Keypad Reset Mode enter the USER CODE to
interrogate the EXITGUARD and enter 2 before any mode
LEDs extinguish. The Code Reset LED illuminates for
about 5 seconds. When it extinguishes the EXITGUARD is
set to Code Reset Mode.
3. To use Auto Re-arm Mode enter the USER CODE to
interrogate the EXITGUARD and enter 3 before any mode
LEDs extinguish. The Auto Re-arm LED illuminates for
about 5 seconds. When it extinguishes the EXITGUARD is
set to Auto Re-arm Mode.
4. To switch to the OFF mode enter the USER CODE to
interrogate the EXITGUARD and enter O before any mode
LEDs extinguish. The Off LED illuminates for about 5
seconds to indicate that the EXITGUARD is switched OFF.
If you need to change the user code proceed as follows:
a. Enter the existing user code to interrogate the
EXITGUARD
b. Enter 7 before any mode LEDs extinguish. This is a
maintenance mode, the
LED will illuminate.
c. Enter 1, a double bleep is heard and the four mode LEDs
illuminate inviting you to enter a new four digit user code.
d. As each digit is entered a mode LED will extinguish.
e. When the code is complete a double bleep is heard. The
unit is now ready for use but in the OFF mode. Don't forget
To be completed by installer
and left with customer.
Note
If the EXITGUARD is sounding enter
the USER CODE
on the keypad to
silence it.
III
III
3
Five incorrect codes will result in keypad
lockout and barp for 10 seconds.
6
Power LED is only illuminated on EX205 and
0
EX206 when correctly powered.
to make a note of this new number or your installation
company may make a charge to reset the EXITGUARD.
WARNING! Do NOT use maintenance mode
have the installation instructions available. See our website
www.hoyles.com. If you accidentally enter this mode key O
to leave it. The EXITGUARD will be in the OFF mode.
Battery Monitor
The EX204 EXITGUARD can be powered from 6 x AA
alkaline batteries. These can last up to 5 years. Before the
batteries become exhausted the EXITGUARD will emit
periodic warning bleeps and the maintenance
flash. On interrogating with the User Code the relevant
mode LED will illuminate also with the
impending battery failure. The batteries can be changed
without losing the user code or set up parameters.
Anti Tamper Protection
All EXITGUARDs are fitted with tamper detection. This is
indicated by a low pitch barp and
LED
Fire Door Checker.
If your EXITGUARD is being used for Fire Door Verification
you will need to open and close each protected door when
the LEDs strobe with a periodic bleep. This may be after
entering the building or at a set time determined by a time
clock. Note: Keypad is locked until verification is complete.
NOT installed.
Installed to operate on entering the building.
Installed to operate at
am/pm on
Mon
Tue
Wed
Thu
Fri
Door Open Too Long (DOTL) delay
Your EXITGUARD may have been set up to incorporate a
delay before sounding, usually for fire doors that are in
regular use where it would be inconvenient to switch off
each time a door is opened for a short period. This is best
used in the Auto Re-arm mode.
This feature is NOT installed
This feature is installed. The delay is set to
Bleep When OFF
Your EXITGUARD may have been set up to bleep
periodically when in the OFF mode. This helps prevent
doors being left un-protected.
This feature is installed.
This feature is NOT installed
Your installation engineer should complete the boxes
above and leave these instructions with you.
Engineer:
Date:
Installation Co.
Telephone Number:
DWG No 60087 Issue 1 Aug 2004
EXITGUARD User Instructions
Power LED
Setup LED
Mode LEDs
Keypad
These user instructions apply to EX204, EX205 and EX206
versions of the EXITGUARD. For details on setting various
functions refer to Installation Instruction 60086. available on
unless you
our website www.hoyles.com.
When your EXITGUARD has been installed and set up you
will have been given a 4 digit USER CODE. Make a note of
the number in the box above, you will need this number to
switch to any of the various modes or to silence the
EXITGUARD if it is sounding.
There are four possible user modes
LED will
1.OFF. The protected door can be opened without sounding
the alarm.
LED to warn of
2.CHIME. When a door opens the EXITGUARD will sound
a short chime, like a shop door bell.
3.KEYPAD RESET.
EXITGUARD sounds until the user code is entered.
4.AUTO RE-ARM. When the door opens the EXITGUARD
sounds and resets a short time after the door is closed (This
time delay is usually set to
You can interrogate the mode status at any time: Simply
type in the User Code, one of the 4 Mode LED will illuminate
for a period of 5 seconds.
1. To use Chime Mode enter the USER CODE to
interrogate the EXITGUARD and enter 1 before any mode
LEDs extinguish. The Chime LED illuminates for about 5
seconds. When it extinguishes the EXITGUARD is set to
Chime Mode.
Sat
Sun
2. To use Keypad Reset Mode enter the USER CODE to
interrogate the EXITGUARD and enter 2 before any mode
LEDs extinguish. The Code Reset LED illuminates for
about 5 seconds. When it extinguishes the EXITGUARD is
set to Code Reset Mode.
3. To use Auto Re-arm Mode enter the USER CODE to
interrogate the EXITGUARD and enter 3 before any mode
LEDs extinguish. The Auto Re-arm LED illuminates for
about 5 seconds. When it extinguishes the EXITGUARD is
secs.
set to Auto Re-arm Mode.
4. To switch to the OFF mode enter the USER CODE to
interrogate the EXITGUARD and enter O before any mode
LEDs extinguish. The Off LED illuminates for about 5
seconds to indicate that the EXITGUARD is switched OFF.
If you need to change the user code proceed as follows:
a. Enter the existing user code to interrogate the
EXITGUARD
b. Enter 7 before any mode LEDs extinguish. This is a
maintenance mode, the
c. Enter 1, a double bleep is heard and the four mode LEDs
illuminate inviting you to enter a new four digit user code.
d. As each digit is entered a mode LED will extinguish.
e. When the code is complete a double bleep is heard. The
unit is now ready for use but in the OFF mode. Don't forget
Note
exitguard
If the EXITGUARD is sounding enter
the USER CODE
on the keypad to
Off
silence it.
I I
II II
III
III
I
Chime mode
1
2
3
Five incorrect codes will result in keypad
II
lockout and barp for 10 seconds.
Keypad reset mode
4
5
6
Power LED is only illuminated on EX205 and
III
7
8
0
Auto re-arm mode
EX206 when correctly powered.
to make a note of this new number or your installation
company may make a charge to reset the EXITGUARD.
WARNING! Do NOT use maintenance mode
have the installation instructions available. See our website
www.hoyles.com. If you accidentally enter this mode key O
to leave it. The EXITGUARD will be in the OFF mode.
Battery Monitor
The EX204 EXITGUARD can be powered from 6 x AA
alkaline batteries. These can last up to 5 years. Before the
batteries become exhausted the EXITGUARD will emit
periodic warning bleeps and the maintenance
flash. On interrogating with the User Code the relevant
mode LED will illuminate also with the
impending battery failure. The batteries can be changed
without losing the user code or set up parameters.
When the door opens the
Anti Tamper Protection
All EXITGUARDs are fitted with tamper detection. This is
indicated by a low pitch barp and
Fire Door Checker.
seconds
If your EXITGUARD is being used for Fire Door Verification
you will need to open and close each protected door when
the LEDs strobe with a periodic bleep. This may be after
entering the building or at a set time determined by a time
clock. Note: Keypad is locked until verification is complete.
NOT installed.
Installed to operate on entering the building.
Installed to operate at
Mon
Door Open Too Long (DOTL) delay
Your EXITGUARD may have been set up to incorporate a
delay before sounding, usually for fire doors that are in
regular use where it would be inconvenient to switch off
each time a door is opened for a short period. This is best
used in the Auto Re-arm mode.
This feature is NOT installed
This feature is installed. The delay is set to
Bleep When OFF
Your EXITGUARD may have been set up to bleep
periodically when in the OFF mode. This helps prevent
doors being left un-protected.
This feature is installed.
This feature is NOT installed
Your installation engineer should complete the boxes
LED will illuminate.
above and leave these instructions with you.
Engineer:
Installation Co.
Telephone Number:
To be completed by installer
and left with customer.
unless you
LED will
LED to warn of
LED
am/pm on
Tue
Wed
Thu
Fri
Sat
Sun
secs.
Date:
DWG No 60087 Issue 1 Aug 2004