Lumantek WEIVER 2.0 Operation Manual

Rf capture and playback system
Hide thumbs Also See for WEIVER 2.0:

Advertisement

Quick Links

WEIVER 2.0 - RF Capture and Playback System
manual
1 / INTRODUCTION
1.1 WEIVER 2.0 System
1.2 User System Requirement
1.3 Optional Upgrade
1.4 Data Flow
1.5 Schematic Diagram
1.6 Control Configuration
1.7 System Specification
2 / SYSTEM DESCRIPTION ----------------14
2.1 WEIVER 2.0 Components
2.2 WEIVER 2.0 Product Configuration
2.3 Installation Precautions
3 / SYSTEM OPERATION ----------------- 17
3.1 WEIVER 2.0 Operatio
3.2 WeiverEX Installation
3.3 WeiverEX Upgrade
3.4 WeiverCom Installation
3.5 WeiverCom Upgrade
--------------------- 8
8
9
10
11
11
12
13
14
15
16
17
17
19
21
23
3.6 Internet (Ethernet Connection)
Connection Method
3.7 Internet (Cross cable
Connection Method
3.8 WeiverEX Operation
* WEIVER Signal Tracer / Converting Util
/ fileUtil 39/60/61
3.9
WeiverEX Program Introduction
3.10 WEIVER Power Button
3.11 WEIVER LED Signal
3.12 WEIVER 2.0 Syncer Operation (option)
3.13 WEIVER 2.0 Bias-Tee Operation(option)
4 / WEIVER 2.0 RF Event Recording ------------ 84
4.1 Features
4.2 Event Recording UI & Settings
4.3 Description of UDP event during recording 88
4.4 Playmode
5 / API OPERATION ---------------------------------- 94
5.1 API Description
5.2 WEIVER API Performance Property
5.3 Data Packet Structure
5.4 Command List
5.5 WEIVER Remote API Source
APPENDIX A. B. C.D ------------------ 117.121.130.134
P
Connection)0
25
26
27
65
75
75
76
83
84
85
89
95
95
97
106
114

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WEIVER 2.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lumantek WEIVER 2.0

  • Page 1 3.12 WEIVER 2.0 Syncer Operation (option) 2.2 WEIVER 2.0 Product Configuration 3.13 WEIVER 2.0 Bias-Tee Operation(option) 2.3 Installation Precautions 4 / WEIVER 2.0 RF Event Recording ------------ 84 3 / SYSTEM OPERATION ----------------- 17 4.1 Features 3.1 WEIVER 2.0 Operatio 4.2 Event Recording UI &...
  • Page 2 Our products reduce the need for travel and transport and Portions of this software are © 1996-2011 LUMANTEK Ltd. All thereby reduce pollution. Our products have either no or few intellectual property rights in such portions of the Software consumable parts (chemicals, toner, gas, paper).
  • Page 3: Operator Safety Summary

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 OPERATOR SAFETY SUMMARY For your protection, please read these safety instructions prong. completely before operating the equipment and keep this The wide blade or third prong is provided for your safety. If manual for future reference.
  • Page 4 1-year limited warranty (including labor and parts). event exceed the purchase price for the defective product. This limitation applies even if Lumantek cannot or does not repair or replace any defective product and your exclusive remedy fails Return Material Authorization Policy of its essential purpose.
  • Page 5 - Is attributable to misuse, improper installation, alteration (including removing or obliterating labels and opening or removing external covers (unless authorized to do so by Lumantek), accident or mishandling while in the possession of someone other than Lumantek. The product was not sold to you as new.
  • Page 6 RF Capture & Playback System ( Frequency from 0.1MHz to 2.7GHz ) WEIVER 2.0 supports BaiduMap & GoogleMap...
  • Page 7 DAB to FM - Handover Testing System for AUTOMOTIVES...
  • Page 8: Introduction

    WEIVER 2.0 Manual Weiver 2.0 / Operations Manual 1. WEIVER 2.0 / INTRODUCTION 1.1 / WEIVER 2.0 SYSTEM WEIVER captures and playsback RF signals with center frequencies between 100KHz ~ 2.7GHz RF signal and stores the file in its internal SSD or optional external SSD.
  • Page 9: User System Requirement

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1.2 / USER SYSTEM REQUIREMENT Your PC(System) must meet the following specification. Computer / Processor - Intel Pentium 4 2.33GHz - Athlon 64 2800 or the faster processor Operating System - Windows xp 32/64 bit service pack(sp2)
  • Page 10: Optional Upgrade

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1.3 / OPTIONAL UPGRADE Bandwidth - 8M Bandwidth(Default) : User can capture 8M Band Width. - 24M / 48M / 56M Band Width(Optional) : User can capture Wide 24M /48M /56M Band Width.
  • Page 11: Schematic Diagram

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1.4 / DATA FLOW PCI - Express Interface I (16-bit) I (16-bit) I (16-bit) Q(16-bit) Q(16-bit) Q(16-bit) Hard Disk (SSD) (16-bit) (16-bit) Upconverter Downconverter Attenuator RF IN RF OUT 1.5 / SCHEMATIC DIAGRAM...
  • Page 12: Control Configuration

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1.6 / CONTROL CONFIGURATION (RECOMMENDED) Control Unit Cross Cable Direct Connection WEIVER Wireless LAN WEIVER Wireless AP Ethernet router, hub, switch LAN(Local Area Network) WEIVER Ad-hoc Wireless Network Ad-hoc(WiFi) WEIVER...
  • Page 13 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1.7 / WEIVER 2.0 SPEC Capture Mode Play Mode Frequency Frequency Frequency Band 0.1 ~ 2700 MHz [HF (High Frequency) Frequency Band HF (High Frequency)_Low Noise] 56MHz max. Real-time Bandwidth 48MHz ~ 2.7GHz...
  • Page 14: Weiver 2.0 Components

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 2. WEIVER 2.0 / Product Description 2.1 / WEIVER 2.0 COMPONENT FRONT REAR Protective Bumper RF In(HF Normal) Cooling Fan (Out) e-SATA Port(hot swap) RF In(HF Low Noise) RF In(LF Normal / LF AM)
  • Page 15: Optional Component

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 2.2 / WEIVER 2.0 Product Configuration Basic Component WEIVER UTP Cross Cable WEIVER 2.0 Body WEIVER Carrier WEIVER AC-DC Adapter WEIVER AC Cord WEIVER Car DC-DC Adapter WEIVER GPS Active Antenna WEIVER Manual USB...
  • Page 16: Installation Precautions

    - Avoid wearing loose, draping clothing, and dangling jewelry when using WEIVER 2.0. - Do not open the WEIVER 2.0 case. Doing so may void the warranty and LUMANTEK takes no responsibility for the damages caused by such action. Should you be experiencing performance issues, please contact your local dealer for assistance.
  • Page 17: System Operation

    Window OS in your laptop or desktop. 3.2 / Weiver_EX Program Installation Please visit LUMANTEK online Download Center at http://www.lumantek.com/support/download.html to download ‘Weiver_EX’ program. Double-click on the program icon will initiate the installation. Click on ‘Next’ to proceed the ‘Weiver_EX’ installation process.
  • Page 18 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Click ‘Install’ to begin installation. The ‘Weiver_EX’ program installation status will be show as pictures below with a progress bar.
  • Page 19 The ‘Weiver_EX’ installation is now completed; click ‘Finish’ to exit the program. 3.3 / Weiver_EX Program Upgrade Please visit us at http://www.lumantek.com/support/download.html to download ‘Weiver_EX’ program. Once downloaded, double-click to upgrade and select ‘Yes’ to uninstall previous version of ‘Weiver_EX’ .
  • Page 20 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Click the Next button to proceed with the WeiverEX installation process. Click the Install button to begin the installation. The WeiverEX program is being installed as shown with the status progress bar.
  • Page 21: Weivercom Installation

    Weiver 2.0 The WeiverEX installation is now complete. Click the Finish button to close the Installation window. 3.4 / WeiverCom Installation Go to the LUMANTEK homepage Download Center (http://www.lumantek.com/support/download. html) to download the WeiverCom program. Once downloaded, double-click to initiate installation.
  • Page 22 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Click the Next button to proceed with the WeiverCom installation process. Click ‘Install’ to begin installation.
  • Page 23: Weivercom Upgrade

    The ‘Weiver_EX’ installation is now completed; click ‘Finish’ to exit the program. 3.5 / WeiverCom Upgrade Please visit us at http://www.lumantek.com/support/download.html to download ‘Weiver_COM' program. Once downloaded, double-click to upgrade and select ‘Yes’ to uninstall previous version of ‘Weiver_COM’ .
  • Page 24 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Click the Next button to proceed with the WeiverCom installation process. Click the Install button to begin the installation.
  • Page 25: Connection Method

    3.6 / EtherNet Connection Method - DHCP is default settings for the WEIVER 2.0’s LAN connection. The WEIVER 2.0 automatically receives the IP address from the Network immediately. - Please access to the ‘Internet Protocol (TCP/IP) Properties’ menu in both PC and the player, make sure ‘Obtain an IP address automatically’...
  • Page 26 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3.7 / Cross Cable Connection Method( use GIgabit LAN port : see page17-no. This section is to show cross cable connection between PC and the Player by using static IP address. Please note that the first three columns of the static IP address for both PC and the player must be identical.
  • Page 27: Weiverex Operation

    Weiver 2.0 3.8 / WeiverEX Operation To use the latest version of the ‘Weiver_EX program’ , please visit our S/W Download page at http://www. lumantek.com. You can find detailed features and functionalities of the ‘Weiver_EX’ program. WeiverEX Program IP Select...
  • Page 28 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Front – RF Port / Ext Port 1) RF IN : HF Normal, Full Band Frequency : 48MHz ~ 2.7GHz => High Frequency Range : +10dBm ~ -55dBm => High Power 2) RF IN : HF Low Noise Frequency : 48MHz ~ 2.7GHz...
  • Page 29 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Setting Within the Setting menu there are 4 unique tabs to choose from. The first tab, Capture includes Frequency, Range, Bandwidth, Simultaneous Playback, AGC. - Frequency : In the Preview or Capture Modes, the frequency can be controlled - Range ( appendix.) : Range features associated with the Capture Mode, the Auto Power...
  • Page 30 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 -AGC Speed : AGC interval can be set to 10ms ~ 500ms . - Recording Stop : Two options, Manual and Auto, are available. In Manual, a user needs to push 'Start' , 'Stop' button.
  • Page 31 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 * Record/Play BW(=IQ Rate*0.8), IQ Rate, Frequency < Record/Play Bandwidth > < Record/Play Frequency Range > * Sample Clock...
  • Page 32 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 The third tab, Viewer includes ResBW, Average, Unit dB and Marker. - ResBW : The ResBW can be adjusted in the Spectrum View’s Resolution. [3KHz, 5KHz, 10KHz, 20KHz]...
  • Page 33 WEIVER 2.0 Manual / Operations Manual Weiver 2.0 * Weiver IQ windowing (WeiverEx) * Weiver FFT (WeiverEx), Capture Mode - BandWidth : 24M(Sampling Clock 30M) ResBW Complex FFT Point Sampling Clock(IQ Rate) 3KHz 10K Point 30MHz(= 3KHz X 10K Point )
  • Page 34 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 The forth tab, System includes Ref(10MHz), Trigger, Storage. - Ref(10MHz) : Select the EXT external Clock for synchronizing with the PLL Clock by external clock signal input.
  • Page 35 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 * Trigger Operation In WEIVERex setting, user can choose to use an external trigger. Trigger On Trigger Off If user equips an external trigger and choose to turn trigger on(in previous page), When you do not push trigger : Low Level(0V) –...
  • Page 36 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Capture Mode Scenario with trigger 1. Insert a trigger in ‘trigger port’ : Low Level(0V) Stopping 2. Trigger’s power On 3. In WEIVERex, Record Start Button Click 4. Activate(push) Trigger : High Level(3.3V) Updating 5.
  • Page 37: Zoom Mode

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Analyzer mouse control in perspective -3D Spectrum Within Spectrum View, the spectrum can be displayed in a simulated 3D style. 3D graph can be controled with mouse control in a perspective way.
  • Page 38 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 View IQ Power @ 30MHz BW - Spectrum By adjusting the frequency in spectrum window, user can observe in-band RF signal (within range of 8M, 24M bandwidth) and by adjusting the Range Input Capture mode, the RF IN signal power can optimized by controlling range in a capture mode.
  • Page 39 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Util * Backup Captured data is by default stored in the D: \ (D Drive). When the default internal storage reaches a remaining capacity of 2GB or less, the Capture function will automatically stop.
  • Page 40: Specification

    WEIVER 2.0 Manual Weiver 2.0 Weiver Signal Tracer WEIVER 2.0 supports BaiduMap & GoogleMap Introduction ‘Weiver Signal Tracer’ provides a user information regarding location, power of RF signal, velocity when analyzing the data captured by WEIVER. In many cases, many circumstantial variables, except for RF signal, makes user have problem to analyze after user captured the data with RF capture equipment.
  • Page 41 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Control Menu 1. File Window Displaying the file’s name after choosing a file. 2. Open button Opening Windows to select *.wpj file. 3. Sample Interval wpj-typed file stores information in one second however, for displaying all information at the map and chart spends plenty of time.
  • Page 42 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 4. Analyze button Displaying information of wpj file on map and chart, using the sample’s time interval. Double-click a marker on the map shows information and click it then information disappear. 5. Repeat button Selecting play mode: one time or repeat .
  • Page 43 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 7. Play button Being based on an analyzed data, user can follow the actual driving route and check information. 8. Pause button 9. Stop button If stop button clicks, a map moves to start point.
  • Page 44 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 11. Print button User can print out a result through a designated printer. 12. Excel button This function supports user to extract an analyzed data as an Excel format file(*.csv) and open and store the...
  • Page 45 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 13. Lumantek Webpage Moving to Lumantek’s webpage when user clicks the logo. 14. Play Bar Displaying the current condition during playing. User can use ‘drag and play’ function. 13. Lumantek Webpage Moving to Lumantek’s webpage when user clicks the logo.
  • Page 46: Navigation Control

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1. Navigation Control User can control left and right or top and bottom of map by clicking navigation control and the movement of map is possible with mouse’s drag. 2. Street View...
  • Page 47 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3. Scale Control To expand or reduce the size of map, it can be controlled by clicking a mouse left-button and the other way is a mouse pointer with scroll function; pointing at the location where a user wants can change the size of the map.
  • Page 48 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Search Menu 1. Virtual Drive Searcher This function supports to search a driving test route before user has. At the route input window, 1) inputting a departure point and an arrival point and then 2) pushing enter or clicking ‘Search button. ’ activates ‘Virtual Drive searcher.
  • Page 49 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 2. Adress Searcher After inputting information regarding the location a user likes to see, pushing ‘enter’ or clicking ‘Address button’ activates ‘Address searcher’ and the searched result displays on the map with a marker. Address searcher service is varied for each country so please refer to the appendix, ‘Google map Service.
  • Page 50: Chart Window

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Chart Window Chart window displays after analyze. The blue-colored graph is for a velocity of the vehicle and the red- colored graph is for RF signal’s power. According to the chart in the above, the signal sharply dropped in two times, approaching mouse pointer to these points makes information of each point indicate at the note.
  • Page 51: Satellite Window

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Satellite Window It is difficult for user to analyze geographical features only with map, in this case, ‘Satellite Window’ helps user analyze, providing satellite map which shares same center with a map. ‘Satellite window’ is automatically controlled by map window and, depending on user’s needs, can be controlled by mouse drag or wheel...
  • Page 52 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 1. Location Informer Window If a user wants to know address and coordinates of the certain location, clicking ‘Location informer button’ makes a maker appear in the center of a map. It indicates the coordinates for the nearest address and the altitude based on the average 0 sea level.
  • Page 53 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Real-Time Traffic Information The Weiver Signal Tracer allows you to see real-time traffic information (where supported) to your maps using the Traffic Function of Weiver signal Tracer. Traffic information is provided for the time at which the request is made.
  • Page 54 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 * Appendix. Google Map Service country/region map tiles geocoding street driving directions Afghanistan Yes (same as tiles) Yes (Major Roads Only) Albania Yes (same as tiles) Yes (Major Cities Only) Yes (MapMaker Only)
  • Page 55 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Burkina Faso Yes (same as tiles) Yes (Major Roads, MapMaker Additions) Burundi Yes (Major Roads, MapMaker Yes (same as tiles) Additions) Cambodia Yes (Major Roads, MapMaker Yes (same as tiles) Additions) Cameroon...
  • Page 56 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Equatorial Guinea Yes (Major Roads Only) Yes (same as tiles) Eritrea Yes (Major Roads, MapMaker Yes (same as tiles) Additions) Estonia Yes (Major Cities Only) Yes (same as tiles) Ethiopia Yes (Major Roads, MapMaker...
  • Page 57 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Ivory Coast Yes (MapMaker Only) Yes (same as tiles) Yes (same as tiles) Jamaica Japan Yes (same as tiles) Jordan Yes (Lacks street names) Yes (same as tiles) Kazakhstan Yes (Major Roads Only)
  • Page 58 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Mongolia Yes (Major Roads, MapMaker Yes (same as tiles) Additions) Montenegro Yes (MapMaker Only) Yes (same as tiles) Yes (Major Cities Only) Montserrat Yes (MapMaker Only) Yes (same as tiles) Morocco Yes (Lacks street names)
  • Page 59 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Russia Yes (In local character Yes (Moscow + Suburbs set only) Only) Rwanda Yes (Major Roads, MapMaker Yes (same as tiles) Additions) Saint Helena Yes (MapMaker Only) Yes (same as tiles) Saint Kitts and Nevis...
  • Page 60 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Timor-Leste Yes (Major Roads Only) Yes (same as tiles) Tokelau Yes (MapMaker Only) Yes (same as tiles) Togo Yes (Major Roads, MapMaker Yes (same as tiles) Additions) Tonga Yes (MapMaker Only) Yes (same as tiles)
  • Page 61 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 * Appendix. Google Map Language Service language code language name ARABIC BASQUE BULGARIAN BENGALI CATALAN CZECH DANISH GERMAN GREEK ENGLISH en-AU ENGLISH (AUSTRALIAN) en-GB ENGLISH (GREAT BRITAIN) SPANISH BASQUE FARSI FINNISH FILIPINO...
  • Page 62 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 BaiduMap Tracer UI GoogleMap Tracer UI...
  • Page 63 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Play File Converting Util Click the start button on your OS and select WeiverFIleConverterUtil inside WeiverEX Program. Once you get the window for converting, ‘Complex type’ files can be played on WEIVER.
  • Page 64 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 WEIVER File Util Run WEIVER file util, and select the original stream to extract part you want.
  • Page 65: Weiverex Program Introduction

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3.9 / WeiverEX Program Introduction When the WeiverEx program is initiated, the WEIVER unit is not yet connected. To proceed with connecting the WEIVER, follow the following sequence: Select Main Menu -> Control-> Connect the device and search WEIVER To connect with WEIVER, a separate WEIVER IP List sub-window will appear.
  • Page 66 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Once the WEIVER has successfully connected, the WEIVER will respond according to the selected mode (Capture or Playback). For the Capture mode, the WeiverEX program will display the incoming RF as a spectrum. Further, the Play mode will playback captured data and transmit.
  • Page 67: Spectrum Analyzer

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 2D Spectrum Analyzer Spectrum Zoom in Analyzer Zoom on the area by clicking first on the left mouse button and dragging to the preferred point and then clicking on the left mouse button. The area the user has selected will be highlighted.
  • Page 68 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 If you want to zoom back to the previous screen, or to the original state, click on or simultaneously press Ctrl+Z. Spectrum Power Marker Band Power Analyzer The Band Power can be measured by clicking the left mouse button and dragging. Once the area has...
  • Page 69 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 View Menu WeiverEX has four sub-windows (with dedicated functions) in the main window. Each sub-window can be repositioned and resized. Further, the Auto Window Position function will automatically resize and reposition the four windows by Auto Window Position.
  • Page 70 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 GPS Graph Displays current location (latitude, longitude) coordinates updated every second. The sizes of the Spectrum Graph , IQ Graph , Power Graph , GPS Graph can be adjusted at the same time.
  • Page 71: Capture Mode

    WEIVER 2.0 Manual / Operations Manual Weiver 2.0 Capture Mode In the Capture Mode, WEIVER will not capture the RF signal automatically but stay in Preview state. To capture the RF signal, press the record button. The center frequency of the spectrum will be displayed in the center of the spectrum window.
  • Page 72 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 The input range for optimizing the RF signal power can be adjusted by clicking on the mouse wheel. Optimize or select Auto Power Adjustment to optimize the power of the RF signal. The range must be higher than the actual RF IN power for getting a optimal RF signal.
  • Page 73: Delete Button

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Play Mode The data files stored in a capture mode are generated in two types(File Name.iqw, File Name.log). File Name.iqw is stored in the order of [I : 2Bytes, Q 2Bytes], File Name.log includes the records of Name.iqw file additional information.
  • Page 74 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 The frequency can be changed with the mouse wheel or by double-clicking and entering in the figures. Gain 30 Gain 0 Gain -30 The transmission power can be changed with the mouse wheel or by double-clicking and entering the...
  • Page 75: Weiver Power Button

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3.10 / WEIVER Power Button Press the button to power on Press the Reset button to reset Press again to power off WEIVER REAR 3.11 / WEIVER LED Signal RF IN(HF Normal, HF Low Noise, HF Normal)
  • Page 76 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3.12 / WEIVER Syncer Operation(Optional) WEIVER Syncer Specification 10MHz OCXO Specification values Freq. Stability vs. Temp ±50 ppb max. Aging per Year ±500 ppb max. Warm-Up @ 25 ºC ±500 ppb max. (In ≤ 3-Minutes) REF 10MHz Output PWR.
  • Page 77 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 CASE 1 ( In case that 2 WEIVERs are synchronized) There are 3 cases for WEIVER Syncer option. REF 10MHz REF 10MHz Trigger Trigger An Line sharer Or network Laptop (two ‘WeiverEx’ are running)
  • Page 78 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 CASE 3 REF 10MHz REF 10MHz Trigger Trigger Connecting with display and Keyboad Connecting with display and Keyboad (WeiverEx is running at the WEIVER) (WeiverEx is running at the WEIVER)
  • Page 79 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Prep for the trigger function (S/W) Record - Preview Mode Button Ref 10MHz Trigger Level Green Push Refresh 3.3 V Push Refresh...
  • Page 80 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Record – Record Mode Button Ref 10MHz Trigger Level Refresh Push After a file name inputs, click record button ( circle marked) Green Push Refresh 3.3 V Push Refresh After some pauses, click record stop button(circle marked) Play –...
  • Page 81 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Button Ref 10MHz Trigger Level Green Push 3.3 V Not fully refreshed Refreshing then emitting RF output Play Stop Record Mode REF 10MHz REF 10MHz Trigger Trigger BW:24MHz or 8MHz BW:24MHz or 8MHz...
  • Page 82: Play Mode

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Play Mode REF 10MHz REF 10MHz Trigger Trigger BW:24MHz or 8MHz BW:24MHz or 8MHz Center Frequency : xxx MHz Center Frequency : xxx MHz Play Play [ File1.wpj ] [ File2.wpj ]...
  • Page 83 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3.13 / WEIVER Bias-Tee Operation(Optional) 1) What is BIAS-TEE? A T-shaped component attached to the signal cable to supply power to the antennas 2) Purpose? Amplifier (LNA, TR, FET and etc) circuits are configured in close proximity to the antennas to improve receive sensitivity, and a separate DC power supply (DC) is required to activate these active elements.
  • Page 84: Weiver 2.0 Rf Event Recording

    - Please Disable ‘EWF’ feature of the Weiver 2.0 System. 1) Double click on ‘ewf_off.bat’ on Weiver Desktop screen. 2) This is necessary because the basic path of the ‘Log’ file will be ‘ C:\Program Files\(c)LUMANTEK\ WeiverEx\Log’ folder. - Please adjust the ‘Time Zone’ of Weiver 2.0 System to your local time.
  • Page 85: Event Recording Ui & Settings

    WEIVER 2.0 Manual Weiver 2.0 4.2 / Event Recording UI & Settings - Run ‘WeiverEx’ program-> Connect to Weiver 2.0 system. 1) Select the RF port for the recording [Capture(LF Normal)] 2) Set the Center Frequency (16MHz) 3) Set Bandwidth (30MHz) 4) Click ‘Spectrum’...
  • Page 86: Menu Description

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Menu description 1) BW Power Event configuration(Enable or Disable )(Adjustable during the recording) 2) UDP Event configuration(Enable or Disable)(Can change Ports during the recording)(Rx Port : 50400 ~ 50500) 3) Recording time and number of ‘Event file’ Configuration(Recording time : 1min or 2min)(Number of Files: 3EA or 5EA) 4) ‘Log’...
  • Page 87 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Recording operation Ready Start Recording Recording Stop/Finish (During recording)
  • Page 88: Description Of Udp Event During Recording

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 4.3 / Description of UDP event during recording - Command header and error check data is not available. - Include texts to UDP packet data and send it to ‘WeiverEx’ . (Each character size is 2-byte) - Ports from 50400 and 50500 are selectable from ‘WeiverEx’...
  • Page 89 WEIVER 2.0 Manual / Operations Manual Weiver 2.0 i.e) When ‘WeiverEx’ receives “set_eventfile 1.44MHz is out” i.e) ‘WeiverEx’ receives the “get_eventfile” 4.4 / Playmode Check the ‘Event’ File list - Change the system to ‘Play’ mode, then click ‘Open’ .
  • Page 90 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Click ‘D:\’->’WeiverData’ folder-> ‘RecordEvent’ Click ‘RecordForever’...
  • Page 91 WEIVER 2.0 Manual / Operations Manual Weiver 2.0 Search files Search Event File ONLY(*.wev)
  • Page 92 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Search for certain time period Use ‘Recorded Before’ and ‘Recorded After’ settings timebase after before timebase before after timebase before timebase after Event File Description(*.wev)
  • Page 93 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 NOTE: Managing the Event file(*.wev) Please copy all *.wev related files for duplication. - Copying a single *.wev file would not work. Delete all *.wev related files. - Deleting ‘*.wev’ file ONLY would remove it from the file list management, not completely deleted. This would prevent system to fully utilize the necessary spaces.
  • Page 94 WEIVER 1.0 / WEIVER 2.0 (playmode only) WEIVER Player 1.0 / WEIVER Player 2.0 By LUMANTEK...
  • Page 95: Weiver Api Performance Property

    The WeiverEx software connects the Weiver software as IP and send UDP packets to run the WEIVER. We have opened the Weiver API example program and packet information because the purpose of the WEIVER API is to control the WEIVER without the WeiverEx software. You can download reference sources at Lumantek website. ( http://www.lumantek.com/support/download.html )
  • Page 96 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 The contents in the below are the structure of API packets (ref.:WvPlayerRemoteAPI.h). #define WEIVER_PLAYER_ID 0x057b50b7 #define WEIVER_PLAYER_API_RX_PORT 50504 #define REMOTE_STRING_SUCCESS _T("Received") #define REMOTE_STRING_INVALIDE_PARAM _T("Invalid Param") typedef enum _WvPlayerRemoteCMD_e WV_PLAYER_REMOTE_CMD_SET_STRING, WV_PLAYER_REMOTE_CMD_MAX }WvPlayerRemoteCMD_t; typedef struct _WvPlayerRemotePacket_t unsigned int u4_ID;// WEIVER_PLAYER_ID...
  • Page 97: Data Packet Structure

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 5.3 / Data Packet structure [ connect 50000 ] Type Reserved Data Size Data Data 0x057b50b7 L”connect 50000” Size(Byte) 13x2 [ disconnect ] Type Reserved Data Size Data Data 0x057b50b7 10x2 L“disconnect”...
  • Page 98 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ play stop ] Type Reserved Data Size Data Data 0x057b50b7 L“play stop” Size(Byte) [ play pause ] Type Reserved Data Size Data Data 0x057b50b7 L“play pause” Size(Byte) 10x2 [ play resume ]...
  • Page 99 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ set freq 400 mhz ] Type Reserved Data Size Data Data 0x057b50b7 L“set freq 400000 khz” Size(Byte) 19x2 [ set freq 400000 khz ] Type Reserved Data Size Data Data 0x057b50b7 L“set freq 400000 khz”...
  • Page 100 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ set gain 100 ] Type Reserved Data Size Data Data 0x057b50b7 L“set gain 100” Size(Byte) 12x2 [ set gain -100 ] Type Reserved Data Size Data Data 0x057b50b7 L“set gain -100”...
  • Page 101 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ get play_section ] Type Reserved Data Size Data Data 0x057b50b7 L“get play_section” Size(Byte) 16x2 [ set play_section 10 20 ] Type Reserved Data Size Data Data 0x057b50b7 L“set play_section 10 20”...
  • Page 102 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ set sample_rate 10000000 ] Type Reserved Data Size Data Data 0x057b50b7 L“set sample_rate 10000000” Size(Byte) 24x2 [ set sample_rate 10000000 hz ] Type Reserved Data Size Data Data 0x057b50b7 L“set sample_rate 10000000 hz”...
  • Page 103 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ get trigger_out_level ] Type Reserved Data Size Data Data 0x057b50b7 L“get trigger_out_level” Size(Byte) 21x2 [ set extclk off ] Type Reserved Data Size Data Data 0x057b50b7 L“set extclk off” Size(Byte) 14x2...
  • Page 104 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ set trigger_in on ] Type Reserved Data Size Data Data 0x057b50b7 L“set trigger_in on” Size(Byte) 17x2 [ set current_directory d:\ ] Type Reserved Data Size Data Data 0x057b50b7 L“set current_directory d:\”...
  • Page 105 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 [ get folder_count ] Type Reserved Data Size Data Data 0x057b50b7 L“get folder_count” Size(Byte) 16x2 [ get foldername 0 ] Type Reserved Data Size Data Data 0x057b50b7 L“get foldername 0” Size(Byte) 16x2...
  • Page 106: Command List

    / Operations Manual WEIVER 2.0 Manual Weiver 2.0 5.4 / Command List Connect, disconnect command, Example) 1. connect 50000, 2. disconnect rescandisk command, Example) 1. rescandisk...
  • Page 107 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 set current_directory, get current_directory command get file_count, get filename, get folder_count, get foldername command openfile, get openfile command Example) 1. set current_directory f:\ 2. get current_directory 3. get file_count 4. get filename 0 5.
  • Page 108 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 play start, play stop, play pause, play resume, get play_status command Example) 1. play start 2. get play_status 3. play pause 4. play resume 5. play stop...
  • Page 109 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 set freq, get freq command Example) 1. set freq 400000000 (400MHz setting) 2. get freq 3. set freq 400 MHz (400MHz setting) 4. set freq 400000 KHz (400MHz setting) 5. set freq 400000000 Hz (400MHz setting)
  • Page 110 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 get gain_min, get gain_max, get rf_out_level 0, get gain, set gain command Example) 1. get gain_min 2. get gain_max 3. get rf_out_level 0 4. set gain 100 5. get rf_out_level 0 6. get gain...
  • Page 111 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 get play_time_total, get play_time_current, set play_time_current, get play_section, set play_section command Example) 1. get play_time_total 2. get play_time_current 3. set play_time_current 5 4. set play_section 6 10 5. get play_section set spec_inv off/on, get spec_inv command Example) 1.
  • Page 112 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 set sample_rate, get sample_rate command Example) 1. set sample_rate 12000000, set sample_rate 12 mhz, set sample_rate 12000 khz 2. get sample_rate set trigger_out_level, get trigger_out_level command Example) 1. set trigger_out_level low 2. set trigger_out_level high...
  • Page 113 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 set extclk, get extclk command Example) 1. set extclk off 2. set extclk on 3. get extclk set trigger_in, get trigger_in command Example) 1. set trigger_in off 2. set trigger_in on 3. get trigger_in...
  • Page 114 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 5.5 / Weiver(Player) Remote API source CWinApp theApp; using namespace std; const unsigned short u2_WeiverPlayerPort = WEIVER_PLAYER_API_RX_PORT; const unsigned short u2_RecvPortFromWeiverPlayer = 50000; const char s1a_WeiverPlayerIP[] = "192.168.100.1"; //const char s1a_WeiverPlayerIP[] = "127.0.0.1";...
  • Page 115 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 if(wcsncmp(wCmdLine, _T("exit"), wcslen(_T("exit"))) == 0) nRetCode = 1; else SendToStringCMD((char*)wCmdLine, 2*wcslen(wCmdLine)); wprintf(_T("\n")); WSACleanup(); return nRetCode; void SendToStringCMD(char unsigned int *s1p_Data, u4_Size) SOCKET h_Socket; SOCKADDR_IN Addr; SentBytes; WvPlayerRemotePacket_t t_Packet; WvPlayerRemotePacket_tp tp_Packet; char *pSendData = (char *)&t_Packet;...
  • Page 116 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 h_Socket = socket(PF_INET, SOCK_DGRAM, IPPROTO_UDP); memset(&Addr, 0, sizeof(Addr)); Addr.sin_family = AF_INET; Addr.sin_port = htons(u2_RecvPortFromWeiverPlayer); Addr.sin_addr.s_addr = htonl(INADDR_ANY); struct timeval timeout; timeout.tv_sec = 2;//2 seconds timeout.tv_usec = 0; optlen = sizeof(timeout); (const char setsockopt(h_Socket, SOL_SOCKET, SO_RCVTIMEO, *)&timeout, optlen);...
  • Page 117 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 SentBytes = sendto(h_Socket ,pSendData ,4/*sizeof(t_Packet.u4_ID)*/ 4/*sizeof(t_Packet.u4_Reserved)*/ 4/*sizeof(t_Packet.u4_DataSize)*/ + u4_Size ,0, (SOCKADDR*)&Addr, sizeof(SOCKADDR_IN)); if(SentBytes == SOCKET_ERROR) Fail")); wprintf(_T("\nSend else memset(&Addr, 0, sizeof(Addr)); length = recvfrom(h_Socket , message, 2000, 0, (SOCKADDR*)&Addr, &clntAddrSize); if(length == -1) wprintf(_T("Time...
  • Page 118 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Appendix. A A-1. Recorded Output File [FileName.iqw, FileName.log] FileName.iqw FileName.wpj Line 1: $Ver,1,IQ FileName,Cap_20110510_090927.iqw,IQ Rate,30000000,Center,474000000,Tracking, 1,AGC,0 Line 2: $GAIN,22.3,POWER,-42.1,,,TIME,1 Line 3: $GPRMC,214614.036,V,,,,,0.00,0.00,060180,,,N*43 Line 4: $GAIN,22.3,POWER,-42.1,,,TIME,2 Line 5: $GPRMC,214615.036,V,,,,,0.00,0.00,060180,,,N*42 Line 1: File Info.
  • Page 119 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 A-2. Weiver MER Range Relation RF IN Power : -60dBm RF IN Power : -30dBm...
  • Page 120 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 A-3. Simultaneous Capture and Playback Real-time Capture & Playback A-4. Arbitrary I/Q Rate Play...
  • Page 121 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 A-5. Configurable Repeat Play...
  • Page 122 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Appendix. B Ghost 15.0 Restore - Please insert the USB Recovery Disk into USB port of Weiver system. Before the Recovery process, Weiver system must be set to use Boot from CD-ROM at BIOS configuration.
  • Page 123 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - Please click the Recover My Computer button on Home tap - Please click the Next button.
  • Page 124 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - Please click the OK button. - Please click the Browse button.
  • Page 125 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - Please select the Weiver_C.V2I file in CD (USB-CD) Drive. - Please click the Next button.
  • Page 126 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - Please click the Edit button. - Please select target to C drive.
  • Page 127 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - Please click the Next button. - Please click the Finish button.
  • Page 128 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - When you click the Yes button, recovery process will be start.
  • Page 129 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - When recovery process finished, please click the Close button. - Please click the Exit button.
  • Page 130 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 - Please click the Yes button. After this process, Weiver system must be reboot.
  • Page 131 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Appendix. C C-1. Weiver External SSD Connection Method...
  • Page 132 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 C-2. Remote Desktop Connection method Factory Default Value for Remote Desktop Connection (ID : Weiver Password : Lumantek) * Case Sensitive...
  • Page 133 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 C-3. Weiver EWF (Enhanced Write Filter) Control[Disable/Enable/State] Please run ewf_off file on Weiver’s desktop for the EWF disablement. * Note : Before the WeiverCom installation or upgrade, EWF must be a disable state. Also, EWF Function must be Working on Weiver’s desktop screen...
  • Page 134 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 Please run ewf_state file on Weiver’s desktop for the EWF state. ewf_state Weiver Spectrum, ResBW...
  • Page 135: Troubleshooting Guide

    WEIVER 2.0 Manual Weiver 2.0 D. Troubleshooting Guide D-1. Unable to Detect Weiver 2.0 Device Update the CMOS through USB memory booting. Please follow next steps. D-2. Unable to find contents of D: \ after completing the booting process Please check the SSD drive. Visit http://www.samsung.com/sec/support/model/MZ-7PD128B/KR-downloads and download Magician Software ver.
  • Page 136 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3. Tick. “make a booting Disk” ” input location of “System Files” . Caution: this operation result in formatting the USB. 4. Copy W0065A10 folder on to the USB...
  • Page 137 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 5. Booting USB is ready. * USB booting for Weiver 2.0 1. Insert the booting USB and enter CMOS . Select booting configuration as USB. 2. Save configurations and boot Weiver 2.0...
  • Page 138 / Operations Manual WEIVER 2.0 Manual Weiver 2.0 3. After booting go to w0065a10 directory and Type “go.bat” and CMOS will be updated. c:\cd w0065a10(enter) c:\go(enter) 4. Done.
  • Page 140 LUMANTEK A-11F, BYC Highcity-A, 131 Gasan Digital 1 Rd., Gasan-dong, Gumchon-Gu, Seoul, KOREA T.Rep (+82) 2-6947-7422 | F (+82) 2-6947-7440 Printed in KOREA WWW.LUMANTEK.COM © Lumantek Co., Ltd. CopyRight 2016...

Table of Contents