Download Print this page

Suttle SOHO Access SAM-V8 Installation Instructions

8-port voice module

Advertisement

Quick Links

TM
SOHO Access
8-Port Voice Module
SAM-V8: 8-port voice module
Package Contents
8-port voice module
I
Designation label
I
Instructions
I
Mount module to enclosure backboard
1
a) Position module with mounting pins aligned to grid holes.
b) While holding the module in place, pull each pin plunger OUT then
rmly push the plunger IN to secure the module to the backboard.
2
Terminate incoming service lines from Telco
a) Route twisted pair cable from the telephone company demarcation
point to the 110 IDC connector LINE IN.
b) Follow the 110 IDC wire termination procedure.
c) Connect tester to the OUT jack and verify incoming dial tone.
3
Terminate premise wiring
a) Route twisted pair cable from the numbered 110 IDC's to the
telephone jacks throughout the premise.
b) Follow 110 IDC wire termination procedure.
c) Record wiring information on the designation label inside
enclosure cover.
4
Test premise wire connections
Connect tester to each outlet jack and verify dial tone.
Note: Use a quali cation tester equipped with an RJ45
(8 position, 8 conductor) test plug.
1
A
B
A
B
2
3
110 IDC Wire Termination Procedure
a) Strip 3 in of outer jacket from the cable.
b) Insert wires into color coded slots as
shown below. Insert the white/blue wire
in the white slot and blue wire in the
blue slot. Repeat with the orange, green
and brown wires.
c) Terminate wires with a punch-tool and
trim excess with a diagonal cutter.
White/Brown
White/Green
White/Orange
White/Blue
Installation Instructions
3
3
3
Brown
Green
Orange
Blue
1
A

Advertisement

loading
Need help?

Need help?

Do you have a question about the SOHO Access SAM-V8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Suttle SOHO Access SAM-V8

  • Page 1 SOHO Access 8-Port Voice Module Installation Instructions SAM-V8: 8-port voice module Package Contents 8-port voice module Designation label Instructions Mount module to enclosure backboard a) Position module with mounting pins aligned to grid holes. 110 IDC Wire Termination Procedure b) While holding the module in place, pull each pin plunger OUT then rmly push the plunger IN to secure the module to the backboard.
  • Page 2: Important Information

    SOHO Access 8-Port Voice Module Installation Instructions Alarm Interface connection to Outlets The 8-Port Voice Module features a security interface port which may be connected to a Phone Signal security system. When the emergency alarm from Alarm Panel is activated, the security system will over-ride telephone service on LINE 1.