iWISE™ QUAD AM Grade 3
Installation Instructions
QUAD PIR Wall Mount with Anti-Mask
iWISE™ QUAD AM Grade 3
iWISE™ QUAD AM Grade 3 uses two separate dual element sensors to reduce false alarms
and improve catch performance.
iWISE™ QUAD AM Grade 3 detectors are the ultimate motion detectors for professional
installations, incorporating Anti-Mask and complying with requirements of PD6662, EN50131-
1 and TS50131-2-2 Grade 3.
iWISE™ QUAD AM Grade 3 detectors are available in 15m model, and include built-in end-
of-line (EOL) resistors to simplify installation.
Main Features
•
Quad PIR technologies
•
Active IR Anti-Masking for meeting
TS50131-2-2 requirements
•
Wall and cover tamper for meeting
TS50131-2-2 requirements
•
Opto-relays for low current consumption
and long life
•
Jumper Selectable EOL (End of Line)
Resistors
PD6662, EN50131-1, TS50131-2-2
•
Local & remote Self Test
Grade 3, Class II
Installation Considerations
•
Before installing, study the area to be protected and select the
location of the unit for the best possible coverage.
•
Corner installations are recommended. The Detector should be
installed so that the beam patterns are at 45° (optimal) to the
intruder's expected path.
•
Avoid installations where machines (e.g. fans) are normally in
operation within the coverage pattern.
Installation/Maintenance
1. To open the front cover:
• Turn the front cover locking screw counter-clockwise.
• Insert a screwdriver through the dedicated slot/s to open the
detector's front cover.
2. Loosen the PCB holding screw, located on the right hand side of the
PCB and slide the PCB down until the screw reaches the widened
opening. Lift the PCB up to remove.
3. Mounting - The iWISE™ QUAD AM Grade 3 can be mounted either
on a flat surface or on a wall corner (corner mounting).
• Using a suitable tool, open the following knockouts on the
detector's base (see Figure 1).
• A1, A2 and A3: External cables knockouts (open out at least one
wiring knockout)
• A4, A6, A9, A12, and A15: Wall mounting knockouts
• When using a swivel adapter use the A4, A6, and A15 openings to
connect the detector to the swivel adapter.
• A8 (optional): Tamper Plate - wall mounting knockout
• A5 and A10: Right corner mounting knockouts
• A7 (optional): Tamper Plate - Right corner mounting knockouts
• A11 and, A14: Left corner mounting knockouts
• A13 (optional): Tamper Plate - Left corner mounting knockout.
14. Changing Lenses - A lens is attached to the inside of the front plastic cover using a sensor protective sleeve (see Figure 3).
• Remove the sensor protecting sleeve by pushing up the clip that holds the top part of the sleeve to the front cover.
• Disconnect the lens from the sleeve by gently lifting it from the holding pins that secure it to the sides of the sleeve.
• Select the desired lens and make sure that the cut corners are pointing upwards.
• Place the two pins, which are located on the top and bottom of the lens, into the matching holes on the sleeve.
• Place the holes on either side of the lens into their matching holding pins located on the sides of the sleeve.
• Insert the protective sleeve back into place on the front cover facing upwards.
iWISE™ QUAD AM Grade 3 - Installation Instructions
•
Remote LEDs disable input
•
Remote Set/Unset control input
•
LED/SET control polarity jumper
•
30 V/m RF immunity
•
Flexible installation height up to
2.7 m (8'10")
•
Coverage 15m x 15m (50ft x 50ft)
•
Creep Zone
•
Wall/corner or ceiling swivel (optional)
•
Wall tamper-proof swivel (optional)
•
Do not mount the detector in direct sunlight or near heat
sources.
•
Point the unit away from glass exposed to the outdoors
and objects that may change temperature rapidly.
•
The installation surface should be solid, smooth and
vibration free.
Note:
If a back tamper is to be used it is mandatory to screw the
tamper back plate to the wall (or wall corner).
4. Use the base as a template for marking the installation
holes (mark through the mounting holes).
5. Put the base in a safe place, drill the required holes in the
surface or in the corner, and insert anchors (if
necessary).Insert external cables through the cable
hole/holes.
6. Mount the rear cover in its final location.
7. The detector's mounting height should be 2.1m-2.7m (6'11"-
8'10").
8. Seal the remaining holes with a sealant compound.
9. Reinstall the PCB into its desired position.
10. Wire terminal (see Terminal Wiring section).
11. Set jumpers (see Jumper Setting section).
Note:
Reset the detector after each change made to the settings.
12. Install the front cover back to its place (in a reverse
sequence of the removal.
13. Perform a Walk test (see Walk Test section).
Figure 2. Back Cover - Knockouts
Figure 3. PCB
A1
A2
A3
A15
A4
ALARM EOL
A5
A14
TAMPER EOL
SHORT FOR FAULT/AM
A6
FAULT/AM EOL
Back tamper
Range
"Breakable" plate
Adjustment
Tamper
Bolt Thread
Switch
A13
A7
A8
Range Mark
A12
A9
Active IR
A11
A10
Anti-Mask Transmitter
Figure 5. iWISE™ QUAD AM Grade 3 Lens
TOP VIEW
Feet
10
30
8
20
6
4
10
2
0
0
2
10
4
20
6
8
30
10
Meters
0
2
4
6
8
10
Feet
0
10
20
30
Terminal Wiring
Terminal
Description
12VDC
- 12 +
12VDC Input
ALARM
N.C. relay
TAMPER
N.C. Tamper Switch
+ 12 -
ALARM
TAMPER FAULT/AM
LED
SET
FAULT/AM
Normally Closed Relay: The FAULT/AM relay opens in the following events:
•
Detector is masked (Alarm relay is also opened)
•
Self test failed
•
Input voltage is lower than 8VDC
LED
LED operation remote control
**
When an
"Activation Signal" is applied to the LED input terminal all LEDs will be disabled.
LEDs are enabled if nothing is connected (unless LED jumper is OFF) or 0V/12V is applied
(according to the LED/SET Input Jumper position, 12V or 0V).
SET
Remote SET/UNSET control
SET: If an
**
"Activation Signal" is applied, anti-mask detection is disabled (for Grade 2
configuration).
UNSET: If nothing is connected or 0V/12V is applied (according to the LED/SET Input
Jumper position, 12V or 0V) anti-mask detection is enabled (see also "Remote Self Test" in
Jumper Settings table).
**
Activation Signal - If 12VDC is applied, and the LED/SET Input Jumper is on 12v position,
0V is applied and LED/SET Input Jumper is on 0V position.
Figure 4. Lens Replacement
+
12
-
Sleeve
ALARM
TAMPER
FAULT/AM
LED
SET
Cut
Terminal
Corners
Block
LEDS
G
R
Y
1K
LED/SET INPUT
2.2K
0V
12V
4.7K
5.6K
LEDS
HIGH
6.8K
OFF
SENSITIVITY
LOW
ON
1K
2.2K
REMOTE
4.7K
5.6K
SELF TEST
LOCAL
6.8K
Lens
12K
Adjustment
Bolt
PIR
Active IR
Sensors
Anti-Mask Receiver
SIDE VIEW
Feet
4
10
2
98°
0
0
Meters
0
2
4
6
8
10 12 14
15
Feet
0
10
20
30
40
50
15
12 14
40
50
-Or -
Short Pin
(facing upwards)
1
Need help?