Locating The Serial Number; Removing And Replacing The Fc San Module - Dell FC SAN User Manual

8/4 gbps
Table of Contents

Advertisement

3

Removing and replacing the FC SAN Module

TABLE 2
Location
4 (icons) and 5
(LED)
6 (icon) 7
(LED)

Locating the serial number

Before contacting service support, be sure to obtain the module's serial number. Use one of these
methods to locate the number:
Removing and replacing the FC SAN Module
Complete the following steps to remove and replace a failed FC SAN Module.
NOTE
Before beginning this procedure, ensure that you have a replacement FC SAN Module or filler panel
available because you do not want to leave the slot on the Blade Enclosure open for an extended
period of time. The slot must be filled with either a replacement FC SAN Module or a filler panel to
maintain proper airflow.
1. Back up the FC SAN Module configuration to an FTP server by using the Module's configUpload
2. Stop all SAN activity requiring the ports used by the FC SAN Module.
3. Remove all cables from the SFP modules.
4. Remove the SFP modules according to the manufacturer's instructions.
24
Key to
Figure 5
(Continued)
Indicator
Color (Continued)
module
green
power
server
blue/amber
management
Use the CLI and enter the ChassisShow command. The FC SAN Module serial number is
displayed along with other data.
Locate the serial number on the label attached to the FC SAN Module. Refer to
page 10 for location.
CLI command and following the prompts.
This command uploads the FC SAN Module configuration to the server, making it available for
downloading to a replacement FC SAN Module if necessary. It is recommended to back up the
configuration on a regular basis to ensure that a complete configuration is available for
downloading to a replacement FC SAN Module.
For details about port management, refer to your Blade Enclosure Hardware Owner's Manual.
Verify that there is no activity by viewing the FC SAN Module LEDs. For details about LED
activity on the FC SAN Module, see
Figure 6
on page 25 details the generic process for removing an SFP from a port.
Operation (Continued)
Off:
FC SAN Module is off or power supplies for the Blade Server
Enclosure or onboard DCC have failed.
Green: Normal operation and power supply is functioning.
properly. Power is supplied by the Blade Server Enclosure.
Controlled by the PowerEdge Blade Enclosure's CLI. For
details, refer to the Hardware Owner's Manual for the Blade
Enclosure.
"Interpreting LED activity"
Dell 8/4Gbps FC SAN Module Hardware User's Manual
Figure 3
on page 23.
53-1001964-01
on

Advertisement

Table of Contents
loading

Table of Contents