RADIATION DOSIMETER
RADEX ONE
USER MANUAL
Radiation dosimeter (radioactivity indicator) is designed to
measure ambient ionized radiation types Beta, Gamma and
X-ray, radioactivity of materials and products, as well as the
radiation dose received.
DISPLAY TYPE
6
7
Icons
and
are visible when these functions are active.
1
1. Measurement result
2. Measurement units
3. Quanta (particle) indicator
ionized particle is registered by the sensor. If the icon
is constantly on, the measurements exceed specified
threshold level.
4. Margin of error is minimal
5. The batteries need to be replaced
6. Audio alarm is ON
7. Vibration alarm is ON
INSTALLING BATTERIES
1. Open the battery compartment
cover on the back of the device.
2. Insert one AAA battery.
3. Close the battery compartment.
Using RADEX ONE
Turning on
Press
to turn on Diagnostic
Mode.
Taking measurements
The device starts taking
measurements immediately as
soon as it is turned on. The first
result is displayed in 10 sec.
To cycle between the modes
press SET: Diagnostic Mode,
Received Dose, CPM (clicks per
minute scale)
.
The device takes measurements
automatically. In case of error,
the display will show ERR.
To get optimal results (lowest
!
margin of error) wait for the n
symbol to appear.
Turning OFF
Press and hold
for several seconds.
7
6
5
4
3
2
flashes every time
Dose rate
Received dose
CPM
Display
Button
Button
MENU DIAGRAM
Received
Dose rate
dose
measurement
measurement
Snd
audio
turn off
signal
Vbr
vibration
turn off
signal
LVS
0.30
threshold
µSv/h
level
CLr
clear received
cancel
dose
SETUP
To enter the Menu or to navigate to the next menu option,
press
.
To enter Sub-Menu or to confirm selection, press
Clip
Battery
compartment
Strap holes
Micro USB
port
CPM
Clicks Per
Minute
OFF
On
turn on
OFF
On
turn on
+ 0.10 µSv/h
0.10
1.00
µSv/h
µSv/h
nO
YES
confirm
.
Need help?
Do you have a question about the RADEX ONE and is the answer not in the manual?
Questions and answers
Can you plug it to a laptop for function. My display has been damaged
Yes, the QUARTA RADEX ONE can be connected to a laptop via a USB port. It requires a Windows operating system (Windows XP, Vista, 7, 8, or later) and the RADEX Data Center software, which can be downloaded and installed for data transfer.
This answer is automatically generated