Wunda E09 Installation Manual

Wiring & plumbing

Advertisement

THE BRAND YOU CAN TRUST

General Guide

The following guide illustrates how Wundafloor warm water underfloor heating systems can be coupled together
with the majority of central heating plumbing and control systems.
The majority of modern central heating systems make use of motorised valves, often called Zone valves, to divide
different heating systems and hot water generation ie. Radiators, Under Floor Heating and Hot water cylinder.
Systems using combination boilers will also need zone valves if separate systems of heating require different times
and temperatures.
Quite often ground and first floors are controlled separately as they may have different uses. The zone valve acts
like a relay, meaning any system can call the boiler/ heat source without other areas being activated.
If the underfloor system is being encorporated alongside a radiator system it is even more important that these
1
areas are controlled independently as 'heat up' and ' c ooling off' times are different. We recommend the 'S' plan
layout is adopted as this allows for more variety in zoning, and should be very familiar to qualified plumber/
electricians. The schematics show typical S-plan heating systems with under floor heating encorporated.
NOTE:
An Auto By-Pass valve (ABV) should be incorporated in all systems.
NOTE:
If a Heat pump manifold has been supplied then there will be no pump on the manifold. Therefore the relay on
the H-Box wiring centre is used to switch on a shunt pump which will send primary water from a
buffer tank or the heatpump itself to the manifolds.

Wundafloor does not supply:

• 'S' plan wiring centre
• Cylinder thermostat
• Hot water time clock
• Auto bypass valve
Motorised / Zone valves and Pipe stats are available if requested.
Installation guide - wiring & plumbing
✆ 0800 5420 816
www.wundafloorheating.co.uk
E09

Plumbing and Wiring Schematics

Section A
System Boiler with hot water cylinder, radiators & UFH
1a) Plumbing Schematic
2a) Multi Zone Wiring Schematic
3a) Single Zone Wiring Schematic
Section B
Combination Boiler with radiators & UFH
1b) Plumbing Schematic
2b) Multi Zone Wiring Schematic
3b) Single Zone Wiring Schematic
Section C
Adding Single Zone kit to exisiting radiator system
1c) Plumbing Schematic
2c) Wiring Schematic
3c) Plumbing Schematic (Danfoss kit)
Section D
H-Box-12 Wiring Schematics
1d) H-Box-12 V1.2
2d) H-Box-12 (previous model)
Section E
Installing a Wet Room Thermostat
Section F
Section G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E09 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wunda E09

  • Page 1 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk General Guide Plumbing and Wiring Schematics The following guide illustrates how Wundafloor warm water underfloor heating systems can be coupled together Section A with the majority of central heating plumbing and control systems. System Boiler with hot water cylinder, radiators &...
  • Page 2 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Section A 1A : Schematic - System Boiler with hot water cylinder, radiators & UFH Radiators Zone Valves Circulation pump Boiler Under Floor Heating system supplied by Wunda...
  • Page 3 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Section A 2A : Typical wiring scheme for multi-zone UHF system with a System Boiler Typical wiring scheme for multi zone UFH system with a System Boiler This drawing is for guidance only.
  • Page 4 Wiring Key Installation guide - wiring & plumbing Orange Radiators Hot Water Zone Valve Zone Valve Zone Valve Grey THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Some Earths & Neutrals Brown omitted for clarity Section A 3A : Typical wiring scheme for single zone UHF system with a System Boiler Typical wiring scheme for single zone UFH system with a System Boiler This drawing is for guidance only.
  • Page 5 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk...
  • Page 6 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk 2B Typical wiring scheme for multi zone UFH with a combination boiler Section B 2B : Typical wiring scheme for multi zone UHF system with a Combination Boiler This drawing is for guidance only.
  • Page 7 Wiring Key Orange L N E 230V Installation guide - wiring & plumbing Grey Radiators Underfloor 50Hz Zone valve Zone valve Brown THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk 3B Typical wiring scheme for single zone UFH with a combination boiler Section B 3B : Typical wiring scheme for single zone UHF system with a Combination Boiler This drawing is for guidance only.
  • Page 8 THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Section C 1C : Schematic - Adding single area UFH to an existing radiator system Radiators Under Floor Heating system supplied by Wunda Combi or System Connections to existing Boiler radiator flow & return...
  • Page 9 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk 2C wiring schematic for single zone kit added to radiator system Section C 2C : Wiring schematic for single zone kit added to radiator system 230V 50Hz Wundafloor Programmable...
  • Page 10 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Section C 3C : Schematic - Danfoss FHV-R Kit to an existing radiator system Radiators This diagram show how a Danfoss FHV-R is connected to and existing radiator system. Please note: Danfoss FHV-R Combi or...
  • Page 11 Current Model (Identifiable by model No. ZDA0003-V1.2 on PCB and addition of L.E.D.) Technical Data. Supply voltage 230V AC, 50/60Hz Output voltage 230V AC,50/60Hz Installation guide - wiring & plumbing Max.Load Number of zone outputs 12 zones Left Hand: 1 x potential free relay output Right Hand:1 x independent relay output Relay Output THE BRAND YOU CAN TRUST...
  • Page 12 Previous model Technical Data. Supply voltage 230V AC, 50/60Hz Output voltage 230V AC,50/60Hz Installation guide - wiring & plumbing Max.Load Number of zone outputs 12 zones Left Hand: 1 x potential free relay output Right Hand:1 x independent relay output Relay Output THE BRAND YOU CAN TRUST (230V AC, 3A)
  • Page 13 Installation guide - wiring & plumbing THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Section E Installing Wet Room Thermostats Unit can be used as a floor temperature sensor or an air temperature sensor. Ensure hole is sealed Stat between wall space and probe housing so that...
  • Page 14 Wireless Control Centre E8.583RF Parameters Installation guide - wiring & plumbing Voltage : AC230V Current : Max 3A Wireless Frequency Output: 433Mhz Effective Transmission Distance: 200m empty space THE BRAND YOU CAN TRUST ✆ 0800 5420 816 www.wundafloorheating.co.uk Ambient Temperature : -5~50°C Pump Linkage: 230V sub-output Boiler/Zone Valve Linkage: Volt free or 230V with link Protective Housing: Ip40...
  • Page 15 Voltage Free Switch • With Optional Link fitted - Can be used as a 230v switch live output to zone valve or boiler/heat source Installation guide - wiring & plumbing Manifold Pump • Without Optional Link fitted - Can be used as low voltage switching for boiler/heat source THE BRAND YOU CAN TRUST ✆...
  • Page 16 Your Notes: Tech support opening hours are subject to change - please visit our website for the latest information...

Table of Contents

Save PDF