DIMENSIONS
ETC 4420
CNT/AL2
SSR
PV
AL1
SV
SET
CSET
ASET
ENDA
TEMPERATURE CONTROLLER
ETC 7420
PV
SV
CNT/AL2
SSR
AL1
SET
CSET
ASET
ENDA
TEMPERATURE CONTROLLER
ETC 8420
PV
SV
AL1
SSR
CNT/AL2
SET
CSET
ASET
ENDA
TEMPERATURE CONTROLLER
98mm
ENDA
ETC 9420
PV
For removing the device from
the panel:
1
the device in direction 1, push it
SV
CNT/AL2
in direction 2.
SSR
AL1
TEMPERATURE CONTROLLER
SET
CSET
ASET
Panel cut-out:
ETC4420
ETC7420
75mm
51mm
+0.6
+0.7
45 mm
68
mm
Note : 1) While panel mounting, additional distance required for
connection cables should be considered.
2) Panel thickness should be maximum 9mm.
3) If there is no 100mm free space at back side of the device,
it would be difficult to remove it from the panel.
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu Barbaros Cad. Kutup Sk. No:20 34775 - ÜMRANÝYE/ÝSTANBUL-TÜRKÝYE
Tel : +90 216 499 46 64 Pbx.
Fax : +90 216 365 74 01
url : www.enda.com.tr
Depth
For removing the device from
87mm
the panel:
- While pressing both side of
1
the device in direction 1, push it
in direction 2.
Connection
cables
Flush mounting
clamp
Panel
2
Enviroment temperature
1
measurement sensor
For removing the device from
Depth
the panel:
-While pressing both side of
97mm
the device in direction 1, push it
2
in direction 2.
Connection
cables
Flush mounting
clamp
Panel
Enviroment temperature
Rubber packing
measurement sensor
Depth
87mm
2
For removing the device from
1
the panel:
-While pressing both side of
the device in direction 1, push it
in direction 2.
Flush mounting
clamp
Panel
Enviroment temperature
measurement sensor
Gasket
Depth
50mm
Flush mounting
clamp
2
-While pressing both side of
Gasket
57mm
Panel
ETC8420
51mm
+0.6
90.5mm
45 mm
4/4
Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the
directions in the user manual. Also we don't accept any compensations for personal injury, metarial damage or capital disadvantages.
ENDA ETC SERIES PID TEMPERATURE CONTROLLERS
Thank you for choosing ENDA ETC SERIES temperature controllers
* Selectable sensor type.
* Automatic calculation of PID parameters (SELF TUNE).
Enter PID parameters of the system if they are known at the begining.
Otherwise, Self-Tune should be activated.
* Soft-Start.
* Communication vai RS-485 ModBus protocol (Optional).
* Selectable SSR or relay control output.
* Relay output can be programmable as second alarm or control output.
* AL1 relay output for first alarm out.
* Selectable Heat/Cool control.
* Input offset feature.
* In the case of sensor failture periodical running or relay state can be
selected.
* Parameter access protection on 3 levels.
* Programming by using keypad or Modbus.
* CE marked according to European Norms.
Order Code : ETC
1
1 - Dimensions
2 - Supply Voltage
4420.....48x48x87mm
7420.....72x72x97mm
8420.....48x96x87mm
9420.....96x96x50mm
TECHNICAL SPECIFICATIONS
Input type
J (Fe-CuNi) Thermocouple
K (NiCr-Ni) Thermocouple
T (Cu-CuNi) Thermocouple
S (Pt10Rh-Pt) Thermocouple
R (Pt13Rh-Pt) Thermocouple
Pt 100 Resistance thermometer
Pt 100 Resistance thermometer
ENVIROMENTAL CONDITIONS
Ambient/storage temperature
0 ... +50
Max. Relative humidity
80% up to 31
Rated population degree
According to EN 60529
Height
Max. 2000m
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply
230VAC +%10 -%20 or 24VAC ±%10, 50/60Hz or by your choose 9-30VDC / 7-24VAC ±%10 SMPS
Power consumption
Max. 7VA (For ETC4420 5VA)
Wiring
2.5mm² screw-terminal connections
Line resistance
For thermocouple max. 100ohm, for 3 wired Pt 100 max. 20ohm
Accuracy
Data retention
EEPROM (minimum 10 years)
EMC
EN 61326-1:1997, A1:1998, A2:2001 (Performance criterion B for standard EN 61000-4-3)
Safety fequirements
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
OUTPUTS
ETC9420
CONT./AL2
Relay : 250V AC, 2A (for resistive load), Selectable as Control or Alarm2 output.
AL1
Relay : 250V AC, 2A (for resistive load), NO/NC selectable. (Alarm1 output).
104mm
SSR out
Selectable logic control output. (Max 12V 20mA).
Life expectancy for relay
Mechanical 30.000.000 operation; Electrical 300.000 operation
CONTROL
Control type
Single set-point and alarm control
Control algorithm
On-Off / P, PI, PD, PID (selectable)
A/D converter
Better than 15 bits
Sampling time
500ms
Adjustable between %0 and %100. If Pb=%0, On-Off control is selected.
Propotional band
Ýntegral time
Adjustable between 0.0 and 100.0 minutes.
Derivative time
Adjustable between 0.00 and 25.00 minutes.
Control period
Adjustable between 1 and 250 seconds.
Hysteresis
Adjustable between 1 and 50
Output power
The ratio of power at a set point can be adjusted between 0% and 100%
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
Dimensions
ETC4420 : G48xY48xD87mm
ETC8420 : G48xY96xD87mm
Weight
Approximately 400g after packing (For ETC4420 250g).
Enclosure material
Self extinguishing plastics.
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
ETCXXXX-E-02-R-A3
-
-
2
3
3 - Modbus Option
230VAC...230V AC
RS.........RS-485 Modbus
24VAC.....24V AC
communication
SM...........9-30V DC /
None.....Don't support RS-485
7-24V AC
Modbus comm.
Temperature range
EN 60584
0... 600
°C
+32... +1112
°F
EN 60584
0...1200
°C
+32... +2192
°F
EN 60584
0... 400
°C
+32... +752
°F
EN 60584
0...1600
°C
+32... +2912
°F
EN 60584
0...1600
°C
+32... +2912
°F
EN 60751
-200...600
°C
-328... +1112
°F
EN 60751
-99.9...300.0
°C
-99.9...+543.0
°F
°C
/ -25... +70
°C (with no icing)
°C
decreasing linearly 50% at 40
°C
.
Front panel
:
IP65
Rear panel
:
IP20
0,2% (of full scale) 1 digit
.If inP=Pt.0, adjustable between 0,1 and 50
°C/F
ETC7420 : G72xY72xD97mm
ETC9420 : G96xY96xD50mm
1/4
ETC 7420
ETC 4420
PV
CNT/AL2
SSR
PV
AL1
SV
SV
CNT/AL2
SET
SSR
AL1
CSET
ASET
ENDA
TEMPERATURE CONTROLLER
SET
CSET
ASET
ENDA
TEMPERATURE CONTROLLER
ETC 8420
ENDA
ETC 9420
PV
PV
SV
CNT/AL2
SV
SSR
AL1
SSR
CNT/AL2
AL1
TEMPERATURE CONTROLLER
SET
SET
CSET
ASET
CSET
ASET
ENDA
TEMPERATURE CONTROLLER
TERMS
PV Display :
Process value during normal operation
Mnemonic parameter code during programming
SV Display :
Set point during normal operation
Date value during programming
Control set key
SET
during normal operation
Parameter selection key
CSET
during programming
Alarm set key
during normal operation
Menu selection key
during programming
ASET
Increment key during normal
operation and programming
Parameter selection key
during programming
Decrement key during
normal operation
If only this key is pressed
in normal operation,
software version number is seen
PV display
7 segment, 4 digits,
red LED indicator
yellow LED ind.(ETC8420)
SV display
7 segment, 4 digits,
yellow LED indicator
PV display :
Character
7mm(ETC4420)
heights
12.5mm(ETC8420)
14mm(ETC7420)
20.3mm(ETC9420)
°C/F
)
SV display :
7mm(ETC4420)
12.5mm(ETC8420)
10.2mm(ETC7420)
14mm(ETC9420)
Mikro Switch
Keypad
3 red LEDs for
Control, Alarm1 and
State indicator
SSR outputs
ETCXXXX-E-02-R-A3
Need help?
Do you have a question about the ETC 4420 and is the answer not in the manual?
Questions and answers