  • Page 1 Instruction Manual Electrical Management System (EMS) EMS-PT30X & EMS-PT50X EMS-PT30X EMS-PT50X...
  • Page 2 INSTRUCTION MANUAL: ELECTRICAL MANAGEMENT SYSTEM (EMS) ProgressiveIndustries.net | 919-267-6964...
  • Page 3 INSTRUCTION MANUAL: ELECTRICAL MANAGEMENT SYSTEM (EMS) Features • High/Low Voltage Protection: The EMS continuously monitors AC power When AC power deviates below 104 volts, for more than six (6) seconds, or rises above 132 volts, the EMS automatically shuts down power to the RV. Once the AC power rises above 104 volts or drops below 132 volts, the 2 minute 16 second (136 seconds) time delay counts down and power is restored automatically.
  • Page 4 INSTRUCTION MANUAL: ELECTRICAL MANAGEMENT SYSTEM (EMS) • Weather Resistant: Unit can be exposed to outside weather elements; however, the unit may not be submerged. Unit is designed to be mounted or used vertically. • Microprocessor Controlled: The EMS utilizes a state-of-the-art microprocessor with proprietary software.
  • Page 5 INSTRUCTION MANUAL: ELECTRICAL MANAGEMENT SYSTEM (EMS) Operating Instructions 1) Plug RV power cord in to the EMS-PT50X (EMS) then plug EMS in to park power. If no Error Code of E 1 through E 9 then wait 136 seconds Time Delay to cycle power to RV.
  • Page 6 E 10 = Replace Surge Protector Module (call technical support) Contact Progressive Industries Tech Support for an E 7, E 8, E 9 or E 10 Error Code. NOTE: If the EMS shuts down power to the RV it will indicate a PE Code (Previous Error) following the Error Code.
  • Page 7 INSTRUCTION MANUAL: ELECTRICAL MANAGEMENT SYSTEM (EMS) Troubleshooting Guide In order for the on-call Progressive Industries Technical Support Team Member to properly diagnose the issue you are experiencing with your unit and render the best possible solution, it is necessary for you TO BE AT YOUR RV when you place a Tech Support call.
  • Page 8 ELECTRICAL MANAGEMENT SYSTEM (EMS) INSTRUCTION MANUAL: Progressive Industries, Inc. For more information regarding the Limited Lifetime Warranty, Troubleshooting and the Warranty Claim Form visit: www.progressiveindustrustries.net Note: Lifetime warranty excludes All Weather Shield assembly. Technical Support • 919.267.6964 • Tech@progressiveindustrustries.net ProgressiveIndustries.net | 919-267-6964 | ZX483 (0518)