4.2
STEP/DIR controlling signals and digital outputs connector
PIN number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
While connecting the STEP/DIR signals to the motor drive (both servo and stepper drives) pay attention to
which STEP edge is active. The active edge in the CSMIO/IP-M is the leading edge – Change of the STEP+
signal from the logic "0" state (0V) to logic "1" (5V).
C S - L a b s . c . – C N C C S M I O / I P - M c o n t r o l l e r
Description
DIR[0]+
STEP[0]+
DIR[1]+
STEP[1]+
DIR[2]+
STEP[2]+
DIR[3]+
STEP[3]+
24V power supply for 0..3 outputs
Output 0
Output 2
Output 4 (NO1 relays)
Output 5 (NO2 relays)
DIR[0]-
STEP[0]-
DIR[1]-
STEP[1]-
DIR[2]-
STEP[2]-
DIR[3]-
STEP[3]-
0V power supply for 0..3 outputs
Output 1
Output 3
Common PIN for relay outputs 4
and 5
The differential outputs on this
connector, have low permissible load
(50mA) and serves only to control the
LEDs in the optically isolated inputs
of motor controller.
Pay
special
attention
connection because STEP/DIR signals
are not protected against short
circuit and voltage higher than 5V!
Digital
outputs
have
permissible load. Pay attention - if
you connect large inductance you
may need to use an additional surge
led, preferably as close to the coil as
possible.
during
250mA
Page 11
Need help?
Do you have a question about the CSMIO/IP-M and is the answer not in the manual?
Questions and answers