Dometic 620515.326 Installation Instructions Manual
Dometic 620515.326 Installation Instructions Manual

Dometic 620515.326 Installation Instructions Manual

Roof top air conditioner & heat pump
Hide thumbs Also See for 620515.326:

Advertisement

USA
SERVICE OFFICE
Dometic Corporation
509 South Poplar Street
LaGrange, IN 46761
260-463-4858
CANADA
Dometic Distribution
866 Langs Drive
Cambridge, Ontario
CANADA N3H 2N7
(519) 653-4390
For Service Center
Assistance Call:
800-544-4881
C
US
INSTALLATION
INSTRUCTIONS
REVISION
Form No. 3109530.067 2/04
(Replaces 3109530.059)
(French 3109884.068)
©2004 Dometic Corporation
LaGrange, IN 46761
620515, 620525, 620526, 630515 &
Roof Top Air Conditioner & Heat Pump
3105935 Quick Cool Return Air Kit
3308120 Genesis Air Filtration System Return Air Kit
3109228.001 Duo-Therm Comfort Control Center™
This Unit Is Designed For OEM Installation. All Initial
Installations Must Be Approved By Dometic Corporation
This manual must be read and un-
derstood before installation, ad-
justment, service, or maintenance
is performed. This unit must be in-
stalled by a qualified service tech-
nician. Modification of this product
can be extremely hazardous and
could result in personal injury or
property damage.
Important:
These Instructions
must stay with unit.
Owner read carefully.
MODELS
630516
Used With
3105007 Return Air Kit
Lire et comprendre ce manuel avant de
procéder à l'installation, à des réglages,
de l'entretien ou des réparations.
L'installation de cet appareil doit être
effectuée par un réparateur qualifié.
Toute modification de cet appareil peut
être extrêmement dangereuse et
entraîner des blessures ou dommages
matériels.
620515.321
620515.326
620515.421
620525.321
620525.326
620525.421
620526.321
1
RECORD THIS UNIT INFORMATION FOR
FUTURE REFERENCE:
Model Number
Serial Number
Date Purchased
MODELS
620526.326
630515.321
630515.326
630515.421
630516.321
630516.326

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 620515.326 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dometic 620515.326

  • Page 1 3308120 Genesis Air Filtration System Return Air Kit LaGrange, IN 46761 260-463-4858 3109228.001 Duo-Therm Comfort Control Center™ This Unit Is Designed For OEM Installation. All Initial CANADA Installations Must Be Approved By Dometic Corporation Dometic Distribution 866 Langs Drive Cambridge, Ontario CANADA N3H 2N7 (519) 653-4390...
  • Page 2: Features

    620515, 620525, 620526, 630515 & 630516 Installation Instructions GENERAL INFORMATION SAFETY INSTRUCTIONS Product features or specifications as described or illus- This manual has safety information and instruc- trated are subject to change without notice. This air conditioner is designed for: tions to help users eliminate or reduce the risk of 1.
  • Page 3 620515, 620525, 620526, 630515 & 630516 Installation Instructions...
  • Page 4: Choosing Proper Location For The Air Conditioner

    RV parked on installation. a level surface. 2. Dometic Corporation will not be liable for any dam- Note: A 8° slant to either side, or front to back, is acceptable ages or injury incurred due to failure in following for 620515, 620525, 620526, 630515 and 630516 series.
  • Page 5: Roof Preparation

    Remember to pro- control to the Dometic A/C. If a furnace is to be vide an entrance hole for power supplies, fur- connected, wires must be run from the furnace to the nace wiring, 4-conductor control cable, remote Dometic A/C.
  • Page 6 Several requirements for this system MUST be met for tions and methods must be approved by the Dometic the air conditioner to operate properly. These require- Corporation in writing. The following instructions are...
  • Page 7 AGS kit. Follow AGS kit instructions for installation. Make sure that at least 15" of the furnace thermostat wires extend into the roof opening. E. Dometic Comfort Control Center™ & Cable 5. If an Energy Management System (load shed fea- Installation...
  • Page 8 620515, 620525, 620526, 630515 & 630516 Installation Instructions FIG. 8 Duct Size And Requirements For 3105007.XXX And 3105935.XXX Return Air Cover Register Required Register Required Short Duct Run Minimum 1/3 Total Duct Length Registers Total Outlet Air Area 8 Min.-- 12 Max. Minimum 21.0 Sq.
  • Page 9: Placing Air Conditioner On The Roof

    620515, 620525, 620526, 630515 & 630516 Installation Instructions FIG. 9C Pin 1 This unit weighs approximately 100 pounds. RJ-11 Connector To prevent back injury, use a mechanical hoist to place Air Conditioner on roof. 3. Lift and place the unit over the prepared opening using the gasket on the unit as a guide.
  • Page 10 620515, 620525, 620526, 630515 & 630516 Installation Instructions b. Remove return air cover and ceiling template FIG. 16 Front of Vehicle from the 3105007.XXX or 3105935.XXX kit car- ton. Roof c. Locate the four 8" x 1/4" x 20 unit mounting Gasket bolts, junction box cover and Romex connec- tor in the 3107180.006 bolt kit.
  • Page 11 620515, 620525, 620526, 630515 & 630516 Installation Instructions 1. All Non-Center Duct Installations Note: The adhesive on the insulation is extremely sticky. Note: The Genesis Air Filtration System can be installed on Be sure the part is located where desired before pressing the units that use a center discharge duct through the 14-1/ into place.
  • Page 12 40 to 50 inch pounds. This will compress ter duct. This duct adapter must be approved by Dometic. the roof gasket to approximately 1/2". a. Check gasket alignment of the air conditioner The bolts are self locking so over tight- ening is not necessary.
  • Page 13 620515, 620525, 620526, 630515 & 630516 Installation Instructions Installation (Installing unit with 3308120.XXX Use Aluminum foil tape (not supplied) to seal Genesis Filtration System Return Air Kit) the ends of the foam divider to the sides of the c. Connect the previously run furnace thermostat opening.
  • Page 14 620515, 620525, 620526, 630515 & 630516 Installation Instructions b. Connect the black wire from the air conditioner Install cover to template with # 8 x 3/8" blunt point and the black wire from the filter indicator light Phillips head screws provided (6 required). with the black negative 12VDC supply wire.
  • Page 15 620515, 620525, 620526, 630515 & 630516 Installation Instructions b. Heat Strip selection - For units with a heat strip FIG. 30 installed at the factory (Model 620515), the #1 dip switch will be in the "ON" position. All other models will have the dip switches in the "OFF" Mode Push-Button position.
  • Page 16 BREAKER BOX BREAKER BOX 2 WIRES 2 WIRES 4-CONDUCTOR 4-CONDUCTOR CONTROL CABLE CONTROL CABLE OPTIONAL OPTIONAL FURNACE FURNACE DOMETIC COMFORT DOMETIC COMFORT CONTROL CENTER CONTROL CENTER FURNACE FURNACE FURNACE 2 WIRES 2 WIRES 14-1/4" x 14-1/4" 14-1/4" x 14-1/4" (±1/8”) OPENING (±1/8”) OPENING...
  • Page 17 620515, 620525, 620526, 630515 & 630516 Installation Instructions WIRING DIAGRAM FOR MODELS 620515.321, 620515.326, 620515.421, 620525.321, 620525.326 620525.421, 620526.321 & 620526.326 PASSED RJ-11 CABLE RJ-11 CABLE DIELECTRIC COMPRESSOR TO COMFORT TO COMFORT GRN/YEL CONTROL FREEZE REMOTE O.L. CONTROL MOTOR SENSOR...

Table of Contents