  • Page 1 I N N O V A T I V E S A U N A T E C H N O L O G Y SteamRock Premium steam generator for steam rooms Installation and operation manual Made in Germany print no. 2934 4827 / 49.17...
  • Page 2: Table Of Contents

    English Contents 1. Identification ............................5 1.1 Manufacturer ..........................5 1.2 Copyright ............................5 1.3 Product identification ......................5 1.4 Intended use ..........................5 1.5 Foreseeable incorrect use ......................5 1.6 Applicable norms ........................6 2. Safety advice ............................7 3. Specifications ............................. 10 4. Delivery scope ............................ 12 5.
  • Page 3 12. Multiple cabins connection ......................41 12.1 How to connect several cabins to one display panel ..........41 12.2 How to program the cabin address (ID) ................42 12.3 Connection example for 8 cabin connection ..............43 13. Operation ............................. 45 •...
  • Page 4 Introduction Dear customer Thank you very much for purchasing EOS sauna & steam equipment. You have purchased a mod- ern, technically advanced product which will provide you with years of reliable service. EOS steam generators have been designed and tested to comply or exceed the currently applica- ble European safety norms and are produced in our factory in accordance with the quality man- agement norms DIN EN ISO 9001:2008.
  • Page 5: Identification

    The copyright owner of the present installation manual and operating guide is EOS Saunatechnik GmbH. 1.3 Identification of the product Steam generator SteamRock Premium 1.4 Intended use The SteamRock Premium steam generator is intended for production of steam in steam rooms. The SteamRock Premium includes a control system with an external display panel.
  • Page 6: Foreseeable Incorrect Use

    1.5 Foreseeable incorrect use Following may be regarded as foreseeable incorrect use: • Steam room size does not match the steam generator power (incorrect power selection). • Operation without legally required safety and protection features. • Operation without proper knowledge of the safety advices (chapter 3). •...
  • Page 7: Safety Advice

    2. Safety advices DANGER Risk of fire and danger of electric shock. Risk of fire by incorrect installation. Make sure to have the steam generator installed only by an ap- • propriately qualified specialist according to the present instruction manual. All electrical connections in the steam generator and other equip- •...
  • Page 8 DANGER Risk of scalding. Hot steam may cause burns, scalding and dangerous to life injuries, if the steam generator has not been properly installed or is operated not as per its intended use. During planning and installation make sure, that the steam out- •...
  • Page 9 WARNING Risk of burns through hot surfaces in the device. The steam generator has hot surfaces, e.g. pipelines, water tank, which may cause burns. Keep a secure distance to hot surfaces of the device. • ATTENTION So-called plasticizers are able to modify the water surface tension in the steam generator water tank.
  • Page 10: Specifications

    3. Specifications Dimensions H x W x D [mm] 670 x 460 x 350 mm Weight 28 kg (Type 1 - 9 kW) / 30 kg (Type 2 - 18 kW) Water supply pressure [bar] 2 - 8 bar Operation pressure max. [bar] Pressureless system.
  • Page 11 Power output Adjustable on site: • Type 1 - 3 / 6 / 9 kW (9 kW default) • Type 2 - 9 / 12 / 15 / 18 kW ( 18 kW default) • Type 1 - 3 x 16 A Fuse protection • Type 2 - 3 x 35 A • Type 1 - 5 x 2,5 mm²...
  • Page 12: Delivery Scope

    4. Delivery scope SteamRock Premium delivery includes: • SteamRock Premium steam generator • EmoTouch 3 display panel with separate bottom housing • Connection cable for control panel, 5 m • Temperature sensor, incl. 5 m connection cable • 4 screws 5 x 40 •...
  • Page 13: Mechanical Installation - Steam Generator

    5. Installation 5.1 General installation overview * For sensor installation please refer to the installation guide supplied with the control unit.
  • Page 14: Construction And Location Of Components

    5.2 SteamRock Premium - location of principal components top view Overpressure valve with discharge Water tank lid Water temperature sensor Water supply (slow lane) Water supply (rinsing) Descaling liquid supply Water level probe Steam output with piv- ot joint connection...
  • Page 15 water tank thermal insulation jacket (removalbe)) water supply line Water drain valve with actuator dosing pump for cleaning system Thermofuse (STB) Essence dosing pumps Heating elements 6x fuse 6,3 x 32 mm 16 A 500 V AC Main board with connec- tion jacks and terminals for connection of sensors, display panel and external equipment...
  • Page 16: Prerequisites On The Installation Site

    5.4 Mechanical installation The SteamRock Premium is a wall-hanging device. It is mounted to the wall with 4 screws. Please ensure that the wall is able to carry the load of min. 45 kg. We recommend to allow certain reserve for safety.
  • Page 17 Drill 4 mounting holes in the wall as shown on the template below. If necessary use the appropriate dowels to securely mount the screws in the drilled holes. At first screw in the two upper screws. As shown on the pic. 2. please make sure to leave 3 mm gap between the screw head and the wall surface.
  • Page 18: How To Open Water Tank

    5.5 How to open water tank The water tank can be opened if required e.g. for servicing & maintenance as described below. 1. Disconnect the power supply and water supply to the steam generator. Remove the housing. 2. Undo 6 hexagonal nuts along the top edge of the water tank lid using an Allen key.
  • Page 19: Water Supply And Drain Connection

    5.6 Water supply and drain connection Important Notice: Please observe the EN 1717 / DIN 1988 and DIN 1986 / EN 12056 4 requirements. It must be ensured that the water may not flow back into the water supply system. If necessary the additional equipment has to be installed to prevent the back-flow.
  • Page 20: Steam Pipe Connection

    5.6 Steam pipe connection • The steam pipe should be heat-resistant to at least 110°C. We recommend copper or stainless steel pipes with Ø35 mm. Do not use small diameter steam pipes! • The steam pipeline should be reclining towards the steam outlet. Sharp angles should be avoided.
  • Page 21: Mechanical Installation - Display Panel

    6. Display panel The display panel may only be mounted out- side the cabin. Make sure that by the door opening the ca. 350 mm steam may not reach the control unit. This 188 mm may cause water condensation on the display panel and damage the entire system.
  • Page 22 Control panel rear side pull the connection cable as a loop twice through the ring Power adaport jack Ferrite ring is obligatory for EMV compliance! (by cable length > 25 m) RJ10 RJ14 Ferrite ring holder Ferrite ring with cable loop RJ10 jack (4x) cabin addresses 1-8 mass storage connector type A...
  • Page 23 Display panel installation Bottom housing installation First install the housing base into the cabin wall (see fig. 7 - 8): 1. Loosen 4 screws holding mounting brackets in the base 2. Pull the connection cable through the opening in the housing base. 3.
  • Page 24 Display panel installation Place the control panel directly in front of the housing base and pay attention to the correct orien- tation - the cable connector shall be at the bottom and the SD card slot / mass storage connector at the top.
  • Page 25: Temperature Sensor (Installation And Connection)

    7. Temperature sensor connection You should not install sensor bus or sauna bus lines and power supply lines together, or lead them through the same duct. Installing these together may leads to malfunctions in the electronics, e.g. error messages that the sensor cannot be recognised. Any cable shielding (if any) must be connected to the earth in the control unit.
  • Page 26 7.2 Temperature sensor - installation overview 30 mm 15. Oktober 2013 14:22:38 S-BUS SENSOR SENSOR SENSOR SENSOR The temperature sensor should be connected to one of the free „Sensor Bus“ ports on the main board. The sensor is fitted with a small intermediate connector right behind the sensor.
  • Page 27: Electrical Connection

    8. Electric Installation Caution! Danger of electrical shock. In the case of an incorrect electrical connection there is a danger of electric shock (also after installation works). Danger to life! Make sure to observe the local legal requirements and codes. All works may be carried out only by a licensed and appropriately qualified electrician.
  • Page 28: Water Level Control

    ! ATTENTION! ! WARNING! RISK OF FATAL INJU- RIES! Do not attempt to plug the sensor(s) into the S-Bus (RJ12) jack ! This will damage Never carry out repairs or installation the main board and the sensor! work yourself. Only a qualified technician may remove the housing cover.
  • Page 29: Connection Plan And Wiring Diagram

    8.5 Connection plan and wiring diagram SteamRock Premium 9 kW Emergency 3000 W 3000 W Emotec EmoTouch III Drain Clean 3000 W Terminal Re ll Fragrance 2 Fragrance 1 Softening Term. Sensor Bussensor Steamroom Sensor SteamRock Premium 9kW (V1.2) SteamRock Classic 9kW (V1.2)
  • Page 30 SteamRock Premium 18 kW Emergency 3000 W 3000 W Emotec EmoTouch III Drain Clean 3000 W Terminal Re ll Fragrance 2 Fragrance 1 Softening S-Bus Sensor 3000 W Bussensor Steamroom 3000 W Sensor 3000 W SteamRock Premium 9kW (V1.2) SteamRock Classic 9kW (V1.2)
  • Page 31: Main Board Connection Overview

    8.6 Main board connection overview SteamRock Premium Fühler Entkalkerniveau Schaltkreis / circuit 1 (9 kW) Wasserstandsregler Sensor descaler level Water level probe Fühler Duftsto niveau EmoTouch 3 Sensor Fragrance level Bedienteil Control panel OFF STB CLEAN CLEAN REFILL FRAGRANCE 2...
  • Page 32: Cabin Light Connection

    8.7 Cabin light connection Make sure to observe the max. load on the “Aux” output - see page 53 (Service settings). ! Attention! If you use the power supply for terminals L1, L2 or L3 to power the circuit The lamp must have at least IP65 protec- connected to the Aux output, please ensure tion class and adequate heat resistance.
  • Page 33: Power Output Adjustment

    Remove the bridge before connection. 8.10 Power output adjustment SteamRock Premium steam generators allow to quickly adjust the power output upon installa- tion on site. You can reduce or increase the steam production in order to suit the steam room cabin size and construction.
  • Page 34: Leakage Current

    8.11 Leakage current Please make sure to observe the DIN EN 60335-1:2012-10 norm in respect to the leakage current. This norm requires that the leakage current may not exceed the following limits at the normal operating temperature: “For stationary class I heating appliances - 0,75 mA or 0,75 mA per kW rated power input of the heating appliance with a maximum of 5 mA, whichever is higher.”...
  • Page 35: Cleaning And Descaling System

    EOS recommends the original EOS cleaner. The warranty will be void by the use of an unsuitable and unapproved cleaner liquid.
  • Page 36 Water hardness Water softening system 1° - 5°dH not obligatory 6° - 10° dH recommended 11° - 15° dH required 16° - 20° dH obligatory > 20° dH obligatory Conversion on water hardness measurement units °dH °e °fH mMol/l German units (°dH) 1°dH = 1,2522 1,7848...
  • Page 37 ! WARNING - Danger of poisoning! For safety reasons no persons may be present in the steam room during the descaling cycle.
  • Page 38: General Operation Principle

    10. General operation advice The SteamRock Premium steam generator does not have an own power disconnection switch. If required such switch must be fitted additionally upon installation. The steam generator will there- fore remain connected to power and is controlled from the integrated external control panel.
  • Page 39: Commissioning And Setup

    11. Putting into service (initial setup) Setup after initial start or after a reset The EmoTouch 3 control unit allows fast and intuitive configuration in several steps by commis- sioning during the first start or after a system reset. 1. Select language Einstellungen Tip on the required language symbol (the Sprache...
  • Page 40 2 steam rooms with up to 4 steam generators per cabin. 1 steam room with up to 8 steam generators bundled for this one cabin. 6. Type of use Shall the cabin be used privately or commercially? Select and confirm: for private use, or for commercial use 7.
  • Page 41: Multiple Cabins Connection

    Multi-cabin connection and configuration The EmoTouch 3 control unit allows to control up to 8 separate cabins from one display panel. These can be saunas, steam rooms or hammams. The connection is made to the 4 connectors (ports) on the rear side of the display panel (see picture below). Please observe, that for each port connection a special ferrite ring should be added to the con- nection cable.
  • Page 42: How To Program The Cabin Address (Id)

    (red LED goes out, green LED starts flashing again). In this manner you can set the address from 1 to 8. By SteamRock Premium generator the Once the new cabin address has been assigned and if the cabin programming button is on the main board...
  • Page 43: Connection Example For 8 Cabin Connection

    Example - connection of 8 cabins to the EmoTouch 3 control panel EmoTouch 3 Bedienteil Display panel Tableau de commande max. max. max. max. SAUNA SAUNA 9 kW 3 kW 3 kW 9 kW Saunaofen Verdampfer Verdampfer Saunaofen Sauna heater Vaporizer Vaporizer Sauna heater...
  • Page 44 Operation interface by multi-cabin control By several cabins connected to the control panel (providing they have been connected and programmed correctly) the multi-cab- in control symbol will appear on the display in the bottom line: 31. Oktober 2016 14:22:38 Example: Sauna cabin The number inside this symbol indicates the number of the currently selected cabin.
  • Page 45: Operation

    13. Operation Control panel - graphic user interface Coloured light Climate query Cabin light (optional) Temperature / Essence dosing Press >3 sec to set temperature and control essence dosing Date & time 31. Oktober 2016 Cabin selection by 14:22:38 multiple cabins On / Off Fault touch >3 sec to...
  • Page 46: Operation Concept

    Method of operating the graphic user interface Briefly touch to select or enable any of the functions available on the graphical user interface (cab- in icon). Keep touching a function (>3 sec) to access the associated settings screen. For safety reasons, you should always press certain symbols icons for more than 3 sec (e.g.
  • Page 47 Make sure to remember the selected pin code! Please bear in mind that in the case this code is lost you will not be able to operate the control unit. In the case the pin code is no longer available and cannot be restored please contact your local EOS dealer or EOS service.
  • Page 48: Current Climate Query

    Graphic user interface GUI and climate conditions check Thanks to the modern GUI you can quickly access all functions and make necessary settings, as well as make a simple instant query for the current climate condition. The symbols on the start screen may be displayed in different colours, in order to indicate the current operation status - e.g.
  • Page 49 Operation and program settings Switching the heating ON/OFF Press the symbol for approx. 3 seconds. The heating will switch on and the display will show the active heating mode (see example on page 24). The light will be also switched on. To switch off the heating, touch the symbol again.
  • Page 50: Timer Programming

    Cabin light on/off Press the lamp on the display briefly to switch the light in the steam bath cabin on or off. Light dimmer You can dim the cabin light infinitely (0 - 100%) Settings to your preference. Light 31. Oktober 2016 Touch the lamp symbol on the display for more 0:22:38 14:22:38...
  • Page 51 • After this step exit programming by touching briefly the “back” symbol. On the start screen in the bottom line you will now see the programmed date and time, e.g. 15.01. and 18:30. Notice: The heating time duration will be as per „Auto-Stop“ setting (page 47). Week timer (recurring switching on the specified days of the week).
  • Page 52 up the interrupted timer operation after an unplanned stop. Operation messages / Warnings The display may show in the bottom line next to the time & date various information messages or warnings as symbols. They will provide important information such as pending or running clean- ing cycle, or will display warning messages.
  • Page 53: Extended Settings

    Extended settings Settings Einstellungen By private use touch briefly the symbol to display the Extended Settings menu. By commercial use press >3 sec on this symbol 5645 and give in the access code to open the Extended Settings menu. By multi-cabin control - this menu must be opened from the Cabin Overview interface.
  • Page 54: Display Lock

    Make sure to remember the selected pin code! Please bear in mind that in the case this code is lost you will not be able to operate the control unit. In the case the pin code is no longer available and cannot be restored please contact your local EOS dealer or EOS service.
  • Page 55: Display Brightness

    Make sure to remember the selected pin code! Please bear in mind that in the case this code is lost you will not be able to operate the control unit. In the case the pin code is no longer available and cannot be restored please contact your local EOS dealer or EOS service.
  • Page 56: Volt-Free Contact Operation

    Potential-free contact PFC (volt-free contact / floating contact) The PFC function allows you to switch some external equipment with the special switch shown on the main cabin interface. For instance the additional light circuit, music or others. To make the “on” or “off” switching touch briefly the symbol on the main cabin interface.
  • Page 57: Service Level Settings

    14. Service and setup settings The EmoTouch 3 control system provides an extensive set of features and tools to setup and opti- mize the operation. This setup menu is protected with a PIN code in order to prevent unauthor- ized access. Press the icon for about 3 seconds until the PIN code prompt appears.
  • Page 58: Overview Of Operation Symbols

    Service area icons Service / maintenance intervals Descaling Choose to set the service/maintenance intervals Manual descaling start. Firmware Update Essence dosing Firmware update possibility for display panel, re- Setting for injection time 1-15 sec and dosing in- lay box or colour light module terval 1-30 min.
  • Page 59: Settings And Functions

    Settings Service- / maintenance intervals Choose this option to set the service and maintenance intervals. Every time the unit is turned on after the set time is over, a reminder and the stored contact details will be displayed briefly. End customers can check the remaining time by choosing „Advanced Settings“...
  • Page 60 Reset Choose this function to reset all settings to their factory defaults. All personal settings will be lost! Following a reset, the control unit will restart and request you to perform a basic setup. Please notice that all connected extension modules will be also reset. Reset options: you can choose to reset a) current cabin only, b) all settings completely.
  • Page 61 Settings and synchronisation options Touch briefly two times the symbol Einstellungen Settings open the settings. A sub-menu will open pot. freier Kontakt potential-free contact and show various options. By selecting the certain option (symbol) °C °C you can assign a specific function to the potential-free output auch as for instance >...
  • Page 62 Fan operation time by cabin-dry mode Here you set how long the fan(s) will operate after the main cabin operation time. Default setting is 30 minutes. In order to use this function the fan(s) should be connected to the outputs Fan 1 and /or Fan 2.
  • Page 63: Firmware Update

    For an update you will need an empty mass storage device with the standard type A connector. • Download the firmware from www.eos-sauna.de/service-support/software and unzip the ZIP file to your mass storage device. • Plug in the mass storage device to the connector on the rear side of the control panel (control panel has to be removed from the bottom housing).
  • Page 64: Maintenance

    Disconnect the steam generator from power before any mainte- • nance and servicing works. Make sure to observe servicing intervals as given below. • Request an assistance from EOS or an authorized EOS dealer by • any questions. Recommended servicing intervals •...
  • Page 65: Troubleshooting

    Use the optionally available filtering grill in the water tank to keep the drain clear. Reason: Actuator or ball valve faulty Solution: Contact EOS customer service for assistance. Fault: Water filling fault Reason: Water supply blocked.
  • Page 66 Reason: Overheating in the water tank. Solution: See point #1 „overheating limiter fuse“. Restart the generator. Fault: Steam outlet spits hot water. Reason: Water foaming. Solution: Check if the water may be foaming due to contamination with oils or similar substances. Clean the tank if necessary. Reason: Steam pipe installed incorrectly, steam pipe blocked by condensed water.
  • Page 67: Recycling

    2012/19/EU. Do not dispose it with the normal household waste. Service Address: EOS Saunatechnik GmbH Schneiderstriesch 1 35759 Driedorf, Germany Tel: +49 (0)2775 82-514 Fax: +49 (0)2775 82-431 servicecenter@eos-sauna.de www.eos-sauna.de...
  • Page 68: General Terms Of Service And Warranty Terms

    General Terms and Conditions of Service shipments via parcel post. The manufacturer shall accept no liability for damage incurred as a result of improper I. Scope packaging in an individual shipment. Unless otherwise agreed in writing in a specific case, VI.

Table of Contents