Page 2
EC Declaration of conformity We, SKF Maintenance Products, Kelvinbaan 16, 3439 MT Nieuwegein, declare that the SKF TKED 1 is designed and manufactured in accordance with European Directive 2004/108/EC of the European Parliament and of the Council of 15 December...
Page 3
1. TKED 1 detects electrical discharge within the frequency range of 50 MHz to 200 MHz: 2. Use the TKED 1 as close as possible to the bearing location to perform a detection. Avoid the vicinity of the cables and the Variable Frequency Drive (VFD) controller, which could induce some disturbances: 3.
Page 4
5. Press the sampling time mode to toggle between the default measuring time (infinite, 10 or 30 seconds): 6. If the measuring time selected is infinite: press the start/stop button once to begin the measurement, and press the start/stop button once again to stop the measurement: SKF TKED 1...
Page 5
The measurement will stop after 30 seconds, or if the start/ stop button is pressed again: 9. To enable/disable the backlit, press the key displaying the light symbol during 1.5 seconds. The backlit will stop automatically after 60 seconds. SKF TKED 1...
Page 6
When the low battery symbol is displayed on the screen, replace the batteries (3 x Alkaline AAA). To access the battery compartment, use a PZ2 screwdriver. Battery life time is - 60 hours without the backlit on - 40 hours with the backlit on: Case dimensions: SKF TKED 1...
Page 7
Storage and service temperature: Content of the kit: • one TKED 1 display unit • one instruction MP5355 • two identical antenna’s Spare part designation: SKF TKED 1...
Need help?
Do you have a question about the TKED 1 and is the answer not in the manual?
Questions and answers