Plug and play temperature controller
Hide thumbs Also See for ITC-308:

Advertisement

Plug and Play Temperature Controller
ITC-308
User Manual
Version 2.2s
Inkbird Tech. Co., Ltd.
Copyright
©
Copyright
2016 Inkbird Tech. Co., Ltd. All rights reserved. No part of this document may be reproduced
without prior written permission.
Disclaimer
Inkbird has made every effort to ensure that the information contained in this document is accurate and
complete; however, the contents of this document are subject to revision without notice. Please contact
Inkbird to ensure you have the latest version of this document.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ITC-308 and is the answer not in the manual?

Questions and answers

Romi Khosla
January 31, 2025

I **** outdide the USD system so I cannot send that one USD to your expert

Romi Khosla
January 31, 2025

yes the model was turned off for two weeks and does not switch on again. it has no power

1 comments:
Mr. Anderson
February 10, 2025

The Inkbird ITC-308 may not be turning on the cooler due to several possible reasons:

1. Power and Connection Issues: Ensure the device is properly powered and connected to WiFi.
2. Cooler Compatibility: Check if the cooler has a built-in thermostat that prevents it from staying on continuously.
3. Sensor Fault: If the sensor is faulty or disconnected, the device will enter fault mode and stop functioning.
4. Over-Temperature Alarm: If the temperature exceeds the measuring range, the controller will stop working.
5. Factory Reset: If connection issues persist, resetting the device to factory settings may help.

Testing the cooler directly in a power socket confirms it is functional, so the issue likely lies with the Inkbird controller.

This answer is automatically generated

Don Walls
April 17, 2025

How do I reset error

User image 68005c28f2a57

Summary of Contents for Inkbird ITC-308

  • Page 1 Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Please contact Inkbird to ensure you have the latest version of this document.
  • Page 2: Table Of Contents

    ITC-308 User Manual Contents 1. Overview ......................3 What is ITC-308? ....................3 Main features ..................... 3 2. Specification ......................4 3. Keys Instruction ....................5 4. Key Operation Instruction ..................6 4.1 Enquiry Set Point ..................6 4.2 How to Set Parameters .................. 6 4.3 Setup Flow Chart ...................
  • Page 3: Overview

    1. Overview What is ITC-308? ITC-308 is an easy-to-use, safe and reliable dual relay output temperature controller. It can be used as over-temperature protection and automatic temperature control system for various electric appliances such as equipment for home-brew, aquarium, pet breeding,...
  • Page 4: Specification

    ITC-308 User Manual 2. Specification Temperature Control Range -50~99 ° C / -58~210 ° F Temperature Resolution 0.1 ° C / 0.1° F Temperature Accuracy ±1° C (-50 ~ 70° C) / ±1° F (-50 ~ 160° F) Temperature Control Mode...
  • Page 5: Keys Instruction

    ITC-308 User Manual 3. Keys Instruction ① PV: Process Value. under running mode, display current temperature; under setting mode, display menu code. ② SV: Setting Value. under running mode, display setting temperature; under setting mode, display setting value. ③ Cooling indicator Lamp: when the light is on, start refrigeration; when the light is flickering, the compressor is under delay protection.
  • Page 6: Key Operation Instruction

    ITC-308 User Manual ⑨ Cooling Device Socket: the socket is for refrigeration output. 4. Key Operation Instruction 4.1 Enquiry Set Point When the controller is working normally, short press “ ” key for one time, then the heating differential (HD) will be displayed; short press “...
  • Page 7: Setup Flow Chart

    ITC-308 User Manual 4.3 Setup Flow Chart 5. Menu Instruction When the temperature is displayed in Centigrade Menu code Function Setting range Default setting Remarks -50~99.9℃ Temperature Set Value 25℃ 0.3~15℃ Heating Differential Value 2.0℃ 0.3~15℃ Cooling Differential Value 2.0℃...
  • Page 8: Temperature Control Range Setting (Ts, Hd, Cd)

    ITC-308 User Manual When the temperature is displayed in Fahrenheit Menu code Function Setting range Default setting Remarks -50~210℉ 77℉ Temperature Set Value 1~30℉ 3℉ Heating Differential Value 1~30℉ 3℉ Cooling Differential Value -50~210℉ 200℉ Alarm High Limit -50~210℉ -40℉...
  • Page 9: Compressor Delay (Pt)

    ITC-308 User Manual When measured temperature is lower or equal to AL, low temperature alarm will be triggered, buzzer will alarm with tone “bi-bi-Biii” until the temperature >AL or any key is pressed. 5.3 Compressor Delay (PT) Under refrigeration mode, after power on, if the measured temperature is higher than the value of setting temperature(TS) plus cooling differential(CD), the equipment won’t start...
  • Page 10: Error Description

    ITC-308 User Manual 6. Error Description Sensor Fault Alarm : when temperature sensor is in short circuit or open loop, the controller will initiate sensor fault mode, and cancel all the actions. The buzzer will alarm, LED displays ER. Buzzer alarm could be dismissed by pressing any key. After faults solved, the system will return to normal working mode.
  • Page 11: Technical Assistance And Warranty

    7.2 Warranty INKBIRD TECH. C.L. warrants this thermostat for one years from the date of purchase when operated under normal condition by the original purchaser (not transferable), against defects caused by INKBIRD’s workmanship or materials. This warranty is limited to the repair or replacement, at INKBIRD’s discretion, of all or part of the thermostat.

Table of Contents

Save PDF