Jets
Hard Button
Opens Jets menu
Options
Hard Button
Accesses spa
settings
Soft Buttons (4)
Control functions,
which change on
screen nearest
each soft button
READY
Water is
near
set temp
IQ 2020
Control Panel
®
Quick
Reference
Memory
102
Media
Spa Status Indicators
Summer
Zone
timer
lighting
Temp lock
All Off
F
o
Clean
Spa or
Jets
(flashes for
cleaning
cycle)
Guide
POWER
Water care
Systems
system
are
(optional)
normal
Lights
Hard Button
Opens
Underwater
Lighting menu
Back
Hard Button
Returns to
previous screen
Home Screen
Displays Home
soft button
functions and
actual spa temp

Advertisement

loading
Need help?

Need help?

Do you have a question about the IQ 2020 and is the answer not in the manual?

Questions and answers

Michael E Petway
April 14, 2025

no power light ,have 240 on 30 amp circuit ,an 240 on 20 amp circuit ,green light an red on board blinking

1 comments:
Mr. Anderson
April 14, 2025

If the HotSpring IQ 2020 has no power light, shows 240V on both the 30 amp and 20 amp circuits, and has a green and red light blinking on the board, it likely indicates a voltage jumper mismatch between the motherboard and the heater relay board. The voltage jumper settings on both boards must match—either both at 12V or both at 18V—depending on the motherboard type. Mismatched jumper settings can prevent proper operation.

This answer is automatically generated

Michael E Petway
April 14, 2025

have a IQ2020 control board, where dose the power come for power light on board

1 comments:
Mr. Anderson
April 14, 2025

The power for the power light on the HotSpring IQ 2020 control board comes from the incoming power wiring connected to the board.

This answer is automatically generated

Michael E Petway
April 14, 2025

does the 30 amp circuit hook to the first one terminal or 2nd 1 terminal

Michael E Petway
April 14, 2025

on the board i have a red light blinking that on, said control unplug ?

Bentley Atchley
April 14, 2025

Logo lights (Status, Ready, Power) cycle as follows: Red, White, White then White, White, White then Green, off, Blue then Green, Green, Blue then all off. All that repeats until power off at the breaker.