Content CHAPTER 1 MAIN SPECIFICATIONS…………………………….…………………….. 2 CHAPTER 2 APPEARANCE AND INSTALLATION…………………….…………….. 3 2.1 KEY FUNCTIONS…………………………………………………………………..….. 3 2.2 LOAD CELL CONNECTION…………………………………………………………... 3 2.3 SCOREBOARD CONNECTION TO THE INDICATOR…………………………..…4 2.4 SERIAL COMMUNICATION AND INDICATOR CONNECTION ……………….….4 CHAPTER 3 CALIBRATION……………………………………………………………..5 3.1 GENERAL CALIBRATION……………………………………………………………...5 3.2 FAST CALIBRATION…………………………………………………………………...
CHAPTER 2 APPEARANCE AND INSTALLATION 2.1 KEY FUNCTIONS Function 【 # 】 When turning on the indicator, keep pressing this key to enter the calibration mode 【Func 】 In weighing mode, keep pressing this key for more than 5 seconds to enter the user parameters setting mode, less than 5 seconds will enter into counting mode.
Non-professional staff is supposed not to be involved in this regard. XK3190-A12+SS can use optional RS232 serial communication interface to communicate with computer. The connection method, please refer to picture 2-4.
The format of N.W: wn000.000kg or wn000.000lb The format of Tare: wt000.000kg or wt000.000lb Note:The position of above decimal is decided by the decimal set on the indicator. (2) In command mode (all of them are ASCII): The indicator performs the corresponding operation according to the command transmitted from the indicator.
[TARE] Press to select the Full capacity setting digit bit; For example: Press when displayed【025000】, [ZERO] Press to change then the full capacity is set to be “25000”, and the [FULL ] the value; indicator enters zero point calibration Press for confirm the input of full capacity Make sure there is no load...
Chapter 4 Operation 4.1 POWER ON AND AUTO ZERO-SETTING 4.1.1 The indicator will perform “000000-999999” to self-checking when turning on. Then it will enter weighing mode. 4.1.2 When power on, if loading weight on the scale deviates from the zero point, but still within zero set range, the indicator will set zero automatically;...
Page 9
In weighing mode, keep pressing [ Func ] for 5 seconds more, it will enter operator setting mode (mode P), there are 12 modes from P1 to P12 for option, press [ * ] to choose the mode and press [Tare] to change the parameter. The description of parameter as follows: 1、P1 kg Lb change x=1:...
explosive materials. ▲! Do not use it where inflammable gases or steams exist. Don’t use it for canning system of compressive container. ▲! In the area where lightning and thunder happen frequently, reliable lightning arrester should be installed to ensure the personal safety and to prevent any damage to the indicator and relative equipment caused by lightning stroke.
Page 12
Please make sure no load is on the scale when turning on ERR 4 The input sample quantity is zero when sampling in counting mode Please input the right sample quantity ERR 5 When full capacity calibrating, the weight input is zero Please input the weight in accordance with the load on scale ERR 6 The unit weight is less than 0.25e when sampling in counting mode...