Appendix
Code table
Code
Possible settings
No.
Name
Lenze
C0410
Free configuration
v
of digital input
signals
1 NSET1−JOG1/3
NSET1−JOG1/3/5/7
(A)
2 NSET1−JOG2/3
NSET1−JOG2/3/6/7
(A)
3 DCTRL1−CW/CCW
4 DCTRL1−QSP
255
5 NSET1−RFG1−STOP
255
6 NSET1−RFG1−0
255
7 MPOT1−UP
255
8 MPOT1−DOWN
255
9 Reserved
255
10 DCTRL1−CINH
255
11 DCTRL1−TRIP−SET
255
12 DCTRL1−TRIP−RESE
255
T
13 DCTRL1−PAR2/4
255
14 DCTRL1−PAR3/4
255
15 MCTRL1−DCB
16
PCTRL1−RFG2−
255
(A)
LOADI
17 DCTRL1−H/Re
255
18 PCTRL1−I−OFF
255
19 PCTRL1−OFF
255
20 Reserved
255
21 PCTRL1−STOP
255
22 DCTRL1−CW/QSP
255
23 DCTRL1−CCW/QSP
255
24 DFIN1−ON
255
14−34
Selection
Link between digital signal sources and internal digital
signals
1
Digital input X3/E1
2
Digital input X3/E2
4
Digital input X3/E4
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
3
Digital input X3/E3
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
Not assigned (FIXED−FREE)
EDB82MV752 EN 5.2
IMPORTANT
A selection made under C0007 is copied
to the corresponding subcode of C0410.
A change of C0410 sets C0007 = 255!
Selection of fixed setpoints
C0410/1
C0410/2
active
C0410/33
C0046
LOW
LOW
LOW
JOG1
HIGH
LOW
LOW
JOG2
LOW
HIGH
LOW
...
...
...
...
JOG7
HIGH
HIGH
HIGH
CW = CW rotation
LOW
CCW = CCW rotation
HIGH
Quick stop (via terminal LOW active)
Ramp function generator main setpoint stop
Ramp function generator input must be set
to "0" for mains setpoint
Motor potentiometer functions
Do not change 255!
Controller inhibit (via terminal LOW active)
External error (via terminal LOW active)
Error reset
Parameter set changeover
(only possible if C0988 = 0)
C0410/13 and C0410/14 must have the
same source in every parameter sets
used. Otherwise it is not possible to
change between the parameter sets
(error message CE5 or CE7).
C0410/13
C0410/14
active
LOW
LOW
PAR1
HIGH
LOW
PAR2
LOW
HIGH
PAR3
HIGH
HIGH
PAR4
DC−injection brake
Actual process controller value
(PCTRL1−ACT) must be connected to
process controller ramp function generator
(PCTRL1−RFG2)
Manual/remote changeover
Switch off I−component of the process
controller
Process controller switch off
Do not change 255!
Process controller stop (value "frozen")
Failsafe change of the direction of rotation
0 = Frequency input not active
1 = Frequency input active
Frequency input configuration under C0425
and C0426
^ 7−68