This owner’s manual is designed to assist owners and installers with the operation, maintenance and installation of your new water filter. It is our sincere hope that this manual is clear, concise and helpful. Detailed instructions on general operating conditions, pre-installation and installation instructions, start-up, and meter programming are included.
Gallon Range .........................20 - 50,000 DIMENSIONS Drain Line ..........................3/4” or 1” NPT Ozone Check Valve ........................3/8” Poly Tube ELECTRICAL CURRENT DRAW AND VOLTAGE ................2.0A/120V NOTE: Operating outside of the optimum pressure range may affect system function. Contact your Hellenbrand support team for information.
PRE-INSTALLATION CHECK LIST (All electrical & plumbing should be done in accordance to all local codes) Storm is limited to indoor installations with lime and/or iron must be replaced. If piping is blocked with Water Pressure: A minimum of 25 pounds of water pressure iron, additional equipment may be needed ahead of the filter to (psi) is required for regeneration.
Start Up Instructions For optimal results, allow the filter media to soak for a 5. Initiate backwash by holding “REGEN” button down until minimum of 12 hours prior to install. This helps to main- piston movement is heard. tain the manufacturer’s specified filtration properties. 6.
PROGRAMMING General Information 12:00 The control valve is the “brain” of your water filter. It consists of the valve body and powerhead with solid state microprocessor. The display panel (see Figure 5) consists of the LCD dis- play and five push buttons which are used in displaying and programming the water filter settings.
SET TIME OF DAY = Up Arrow = Down Arrow STEP 1 Step 1 - Press SET CLOCK. Step 2 - Current Time (hour): Set the hour of the day using or buttons. AM/PM toggles after 12. Press NEXT to go to step 3. STEP 2 SET TIME 6:35...
TROUBLE SHOOTING PROBLEM CAUSE CORRECTION Control valve stalled in regeneration A. Motor not operating A. Replace Motor B. No electric power at outlet B. Repair outlet or use working outlet C. Defective transformer C. Should provide 12 volts when plugged into outlet, if not, replace transformer D.
PM6 IC STORM Item Description Part # Metered Control 110270, specify flow control 3&4 Mineral Tank Assembly IC-Storm 1054 Filter Tank 104022 Tank & Distributor Tube Only IC-Storm 1252 Filter Tank 108294 Tank & Distributor Tube Only IC-Storm 1354 Filter Tank 108295 Tank &...
RECOMMENDED ANNUAL MAINTENANCE Annually • Test raw water, assure filter settings are appropriate for the application. Note and record any changes. • Verify injector is clean and functioning. (stock code 101832) • View head of air and determine need for cleaning inlet diffuser by running at service flow and then note difference when bypass open.
® ® Hellenbrand, Inc., warrants to the original consumer purchaser that the system and the parts listed below will be free from defects in material and/or workmanship from the date of the original installation for the following time periods: For a Period of FIVE YEARS: The filter control valve electrical parts including the motor and board, control valve body, excluding internal parts.