2.7 Sleep Mode

SLEEP Mode can be activated through the remote controller to keep the thermal comfort while sleeping.
SLEEP Mode continues operation at the target temperature for the first hour, then automatically raises the target
temperature slightly in case of cooling, or lowers it slightly in case of heating. This prevents excessive cooling in
summer and excessive heating in winter to ensure comfortable sleeping conditions, and also saves electricity.
ON signal of sleep operation
ON signal of sleep operation+operation ON signal
target temperature
<COOL or DRY>
target temperature
<HEAT>

2.8 Quiet function

• Press for quiet operation (for FTK(X)B-AX models) or (for FTK(X)N-AX models) for quiet operation
• Fan speed turns to minimum speed.
• Press again to deactivate the function.
• Available in HEAT and COOL modes only.
• Any change of fan speed will deactivate this function.
2.9 ECO+ function (Applicable for FTK(X)B-AX models)
• Press for eco-friendly mode cooling or heating operation.
• Set temperature automatically adjusts to eco-friendly level.
• Press again to deactivate the function.
• Available in HEAT and COOL modes only.
User set
temperature <
24°C (75°F)
User set
temperature =
24°C (75°F)
Unit runs at (user set temperature + 1°C/2°F)
User set
set temp
temperature >
24°C (75°F)
run
sleep operation
1hr
1hr
(no offset on target
temperature)
(shift 0.5°C/0.9°F)
(shift 1.0°C/1.8°F)
Cool mode
Unit runs at 24°C (75°F)
24
User set
temp
ECO+ activated
Unit runs at 24°C (75°F)
(User set temp + 1⁰C/2°F)
User
24
ECO+ activated
OFF signal of sleep operation
operation OFF signal
(shift 1.0°C/1.8°F)
(shift 1.0°C/1.8°F)
Unit runs at (user set temperature - 1°C/2°F)
24
User
set temp
Unit runs at 24°C (75°F)
Unit runs at 24°C (75°F)
User
set temp
24
Algorithm & Control
Heat mode
(User set temp - 1 C/2 F)
ECO+ activated
ECO+ activated
20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTKB09AXVJU and is the answer not in the manual?

Questions and answers

JOHN GRANT
January 26, 2025

HI. I **** trying to find some clear and simple instructions/information on how to properly use the remote control for my RXB24AXVJU mini split. Thank you.

Mike Hazelwood
February 24, 2025

part number for discharge pipe thermistor, outdoor thermistor, and out door heat exchanger for a BXB18AXVJU UNIT

John Mann
April 17, 2025

Proper testing pressure requirements

ERNEST GIDDENS
April 25, 2025

RXB24AXVJU OUTDOOR FAN NOT COMING ON

Table of Contents

Save PDF