Fuji Electric FRN0025C2S-2U Instruction Manual

Fuji Electric FRN0025C2S-2U Instruction Manual

Frenic-mini series compact inverter
Hide thumbs Also See for FRN0025C2S-2U:

Advertisement

Compact Inverter
Three-phase 200 V series: FRN0025 to 0060C2S-2U
Three-phase 400 V series: FRN0013 to 0030C2S-4U
Thank you for purchasing our FRENIC-Mini series of inverters.
• This manual is a supplement to the FRENIC-Mini Instruction Manual (INR-SI47-1729-E,
INR-SI47-1745-E). It describes the FRENIC-C2S (Inverter types FRN0025 to 0060C2S-2U
and FRN0013 to 0030C2S-4U). For other descriptions, refer to the original manual.
• Improper handling might result in incorrect operation, a short life, or even a failure of this
product as well as the motor.
• Deliver this manual to the end user of this product. Keep this manual in a safe place until this
product is discarded..
Fuji Electric Co., Ltd.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Supplement for FRN-C2S-2U/4U (7.5 to 20 HP)
Instruction Manual
INR-SI47-1833-E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRN0025C2S-2U and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fuji Electric FRN0025C2S-2U

  • Page 1 • Deliver this manual to the end user of this product. Keep this manual in a safe place until this product is discarded.. Fuji Electric Co., Ltd. INR-SI47-1833-E Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com...
  • Page 2: Chapter 2 Mounting And Wiring Of The Inverter

    Table 2.3 Main Circuit Terminals Power Nominal ap- Tightening Terminal supply plied motor Inverter type torque Refer to: screw size voltage (HP) (lb-in) FRN0025C2S-2U 26.6 Figure E Three- FRN0033C2S-2U phase FRN0047C2S-2U 200 V 51.3 Figure F FRN0060C2S-2U FRN0013C2S-4U 26.6 Figure E...
  • Page 3 Table 2.6 Recommended Wire Sizes (Continued) Recommended wire size (AWG ) *1 Main circuit Nomi- Main circuit power input applied Inverter type Braking Control [L1/R, L2/S, L3/T] Inverter motor resistor circuit [L1/L, L2/N] output [P1, P (+)] (HP) [P (+), DB] Grounding [ [U, V, W] w/ DCR...
  • Page 4: Chapter 5 Function Codes

    F11/A07/ supply Inverter type E34/E37 voltage Function (HP) Function code Function code code F09/A05 P02/A16 Shipping destina- tion (version) 5.50 FRN0025C2S-2U 20.06 Three- 7.50 FRN0033C2S-2U 25.72 phase 11.00 FRN0047C2S-2U 37.21 200 V 15.00 FRN0060C2S-2U 48.50 5.50 FRN0013C2S-4U 10.24 Three- 7.50...
  • Page 5: Details Of Function Codes

    (Period: 100 s or less) Power Resistance supply Inverter type Discharging Braking Allowable Duty voltage Type Qty. capability time average loss (%ED) (kWs) (kW) FRN0025C2S-2U DB5.5-2 0.138 Three- FRN0033C2S-2U DB7.5-2 0.188 phase FRN0047C2S-2U DB11-2 0.275 200 V FRN0060C2S-2U DB15-2 0.375 FRN0013C2S-4U DB5.5-4 0.138...
  • Page 6: Standard Models

    Chapter 8 SPECIFICATIONS Standard Models 8.1.1 Three-phase 200 V class series Item Specifications Type (FRN_ _ _ _ C2S-2U) 0025 0033 0047 0060 Applicable motor rating (HP) *1 Rated capacity (kVA) *2 Rated voltage (V) *3 Three-phase, 200 to 240 V (with AVR function) 33.0 47.0 60.0...
  • Page 7 8.1.2 Three-phase 400 V class series Item Specifications Type (FRN_ _ _ _ C2S-4U) 0013 0018 0024 0030 Applicable motor rating (HP) *1 Rated capacity (kVA) *2 Rated voltage (V) *3 Three-phase, 380 to 480 V (with AVR function) Rated current (A) 13.0 18.0 24.0...
  • Page 8: External Dimensions

    8.4 External Dimensions 8.4.1 Standard models Unit inch [mm] Power supply Inverter type voltage FRN0025C2S-2U Three-phase 200 V FRN0033C2S-2U FRN0013C2S-4U Three-phase 400 V FRN0018C2S-4U Power supply Inverter type voltage FRN0047C2S-2U Three-phase 200 V FRN0060C2S-2U FRN0024C2S-4U Three-phase 400 V FRN0030C2S-4U Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com...
  • Page 9: Chapter 10 Application Of Dc Reactors (Dcrs)

    Recommended rated current (A) of (ELCB) * Power motor MCCB and RCD/ELCB Inverter type supply * with overcurrent rating voltage w/ DC reactor w/o DC reactor protection (HP) FRN0025C2S-2U Three- FRN0033C2S-2U phase FRN0047C2S-2U 200 V FRN0060C2S-2U FRN0013C2S-4U Three- FRN0018C2S-4U phase FRN0024C2S-4U 400 V FRN0030C2S-4U...
  • Page 10: Chapter 11 Compliance With Standards

    Table 10.1 List of DC Reactors (DCRs) Power Nominal applied supply Applicable inverter type DCR type motor (HP) voltage FRN0025C2S-2U DCR2-5.5 Three- FRN0033C2S-2U DCR2-7.5 phase FRN0047C2S-2U DCR2-11 200 V FRN0060C2S-2U DCR2-15 FRN0013C2S-4U DCR4-5.5 Three- FRN0018C2S-4U DCR4-7.5 phase FRN0024C2S-4U DCR4-11 400 V...
  • Page 11: Compliance With The Low Voltage Directive In The Eu

    11.4 Compliance with the Low Voltage Directive in the EU 11.4.1 General General-purpose inverters are regulated by the Low Voltage Directive in the EU. Fuji Electric has obtained the proper certification for the Low Voltage Directive from the official inspection agency. Fuji Electric states that all our inverters with CE marking are compliant with the Low Voltage Directive.
  • Page 12 30B, [U, V, Grounding [ (HP) resistor 30C) [P (+), w/o DCR w/ DCR w/ DCR w/o DCR FRN0025C2S-2U FRN0033C2S-2U FRN0047C2S-2U FRN0060C2S-2U FRN0013C2S-4U FRN0018C2S-4U FRN0024C2S-4U FRN0030C2S-4U MCCB: Molded case circuit breaker RCD: Residual-current-operated protective device ELCB: Earth leakage circuit breaker *1 The frame size and model of the MCCB or RCD/ELCB (with overcurrent protection) will vary, de- pending on the power transformer capacity.
  • Page 13 13. To prevent the risk of hazardous accidents that could be caused by damage of the inverter, install the specified fuses in the supply side (primary side) according to the following tables. - Breaking capacity: Min. 10 kA - Rated voltage: Min. 500 V Fuse rating Inverter type FRN0025C2S-2U 125(IEC60269-4) 160(IEC60269-4) FRN0033C2S-2U FRN0047C2S-2U 160(IEC60269-4)
  • Page 14: Compliance With Ul Standards And Canadian Standards (Cul Certification)

    Conformity to the Low Voltage Directive in the EU (Continued) *1 Use this inverter at the following IT system. Non-earthed (isolated from earth) IT Can be used. system In this case the insulation between the control interface and the main circuit of the inverter is IT system which earthed neutral basic insulation.
  • Page 15 When protected by class J fuses, suitable for use on a circuit capable of delivering not more than B rms symmetrical amperes, A volts maximum. Power Power supply max. voltage Power supply current supply Inverter type Volts Amperes voltage FRN0025C2S-2U FRN0033C2S-2U 240VAC 100,000 A or less FRN0047C2S-2U FRN0060C2S-2U FRN0013C2S-4U FRN0018C2S-4U 480VAC 100,000 A or less...
  • Page 16 In no event will Fuji Electric Co., Ltd. be liable for any direct or indirect damages resulting from the application of the information in this manual.

Table of Contents