usi 5304 Instruction Manual

usi 5304 Instruction Manual

Smoke & fire alarm with silence feature and alarm origination feature
Hide thumbs Also See for 5304:

Advertisement

SMOKE & FIRE ALARM WITH SILENCE FEATURE
This smoke alarm uses an extremely small amount of a radioactive
element in the ionization chamber. Do not tamper with radioactive sealed
source or try to repair the smoke alarm yourself.
Smoke Alarm Limitations and Functions ................................. 2
Recommended Location of Alarms.......................................... 3
Avoid These Locations ............................................................ 4
Early Warning .......................................................................... 4
Installation Instructions ............................................................ 4
Electrical Shock Hazard .......................................................... 4
Locking/Tamper Feature .......................................................... 4
Wiring Instructions ................................................................... 5
Operation, Testing & Maintenance .......................................... 6
Cautions/Warnings .................................................................. 7
Silence Feature ....................................................................... 7
Backup Battery Replacement .................................................. 8
Develop and Practice a Plan of Escape .................................. 8
Operational Summary.............................................................. 9
Warranty ..................................................................Back Cover
MODEL 5304, 5304L
AND ALARM ORIGINATION FEATURE
READ ALL INSTRUCTIONS

Table of Contents:

Alarm Originating Feature & Reset................... 7
®
Page #

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5304 and is the answer not in the manual?

Questions and answers

Subir Guha
January 18, 2025

New smoke alarm usi 5304 plugged into interconnected system beeps 5 times pauses and repeats. This continues indefinitely.anyway to fix?alarm goes off when main power switched off

1 comments:
Mr. Anderson
February 4, 2025

If a USI 5304 smoke alarm is beeping 5 times and continues indefinitely when plugged into an interconnected system, follow these steps:

1. Check Battery Installation: Ensure the battery activation pull tab is fully removed, the battery polarity is correct, and the battery terminals make proper contact. Replace the 9V battery if necessary.

2. Quick Find® Feature: Use the Quick Find® feature to determine if the issue originated from another interconnected alarm. Press the Test/Silence button on any alarm. The originating alarm will continue sounding for approximately 50 seconds after the test sequence ends. Address the issue on the originating alarm.

3. Reset the Alarm: To reset the alarm, press and hold the Test/Silence button for approximately 10 seconds. This clears the alarm origination.

4. Verify Connections: Check the wiring and interconnections to ensure the system is properly installed and connected.

5. Test the Alarm: After troubleshooting, test the alarm by pressing the Test/Silence button. The alarm should sound if it is functioning correctly.

If the problem persists, consider replacing the unit, as it may be defective.

This answer is automatically generated

Summary of Contents for usi 5304

  • Page 1: Table Of Contents

    MODEL 5304, 5304L SMOKE & FIRE ALARM WITH SILENCE FEATURE AND ALARM ORIGINATION FEATURE READ ALL INSTRUCTIONS This smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber. Do not tamper with radioactive sealed source or try to repair the smoke alarm yourself.
  • Page 2: Smoke Alarm Limitations And Functions

    SMOKE ALARM LIMITATIONS AND FUNCTIONS • There are three basic smoke alarm types: Universal Smoke Sensing Technology , Ionization and ® Photoelectric • Universal Smoke Sensing Technology is an ionization alarm containing patented Smart Alarm ® • Ionization • Photoelectric burning in couches or bedding.
  • Page 3: Recommended Location Of Alarms

    RECOMMENDED LOCATION OF ALARMS route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a smoke alarm at each end. and heat.
  • Page 4: Avoid These Locations

    AVOID THESE LOCATIONS Silence Feature for these areas. • in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms F (4.4 C) or rise above 100 F (37.8 • closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle) fan. THIS SMOKE ALARM WILL NOT WORK WITHOUT 120 VAC POWER AND A GOOD BATTERY PROPERLY INSTALLED.
  • Page 5: Wiring Instructions

    Insulate this wire (tape it) in place to make certain the yellow wire cannot contact any metal parts. total of not more than 24 interconnected devices, i.e., as many as 11 other USI ELECTRIC or UNIVERSAL model smoke alarms or combination smoke and carbon monoxide (CO) or smoke and carbon monoxide / natural gas alarms;...
  • Page 6: Operation, Testing & Maintenance

    / event or heat alarm / event initiates the alarm. All CO alarms remain silent. Note that smoke alarms without battery backup will not respond during an AC power failure. NOTE: Relay Modules/USI-960 will not respond if a CO alarm / event initiates the alarm. 120 VAC 60Hz 100mA Max.
  • Page 7: Quick Find

    NUISANCE ALARMS: particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooking surface. Large quantities of combustion particles are generated from spills or broiling. the alarm. Use the Silence Feature if it is a nuisance alarm, or reset the alarm by pressing and holding the test button for ten seconds.
  • Page 8: Backup Battery Replacement

    (UTHA) MAINTENANCE: may be used to clear the sensing chamber of dust. Clean the smoke alarm at least once a month cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris. If the smoke alarm is false alarming and cannot be restored to normal operation, the smoke alarm should be replaced.
  • Page 9: Operational Summary

    NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED INFORMATION (1) *In all sleeping rooms and guest rooms sleeping room, the distance measured along a path of travel (4) On every level of a residential board and care occupancy (small facility), including basements (5) *In the living area(s) of a guest suite (6) In the living area(s) of a residential board and care occupancy"...
  • Page 10: Warranty

    If this product is found to be defective, USI’s only obligation, and your exclusive remedy, is the repair or replacement of the product, at USI’s discretion, provided the product has not been damaged through misuse,...

This manual is also suitable for: