Summary of Contents for DIVERSITECH ClearVue

  • Page 1 ClearVue Pump ™ System Installation PUMP ™...
  • Page 2 Contents Introduction 3 Variable Speed and Li 5 Floatless Sensor™ 7 Other Features System Installation Unpacking, Pump Location and Mounting 10 Electrical and High Level Alarm Connection 11 Inlet and Outlet Tubing Connections 12 Electrical Installation Requirements and Safety Switch Connections Operation 12 Power, Pump Test, and Normal Operation 13 Variable Li , Cleaning, and Homeowner Instruction...
  • Page 3 ClearVue™ uses patent pending water sensing technology to detect condensate so that there are no more stuck oats! ClearVue™ also features a see-through tank to give the service tech and homeowner a clear view of water, blockage, and buildup in the tank.
  • Page 4 ClearVue™ needs to pump in a given installation, then pumps only to that height. If there is a partial clog in the drain line, ClearVue™ figures that out, and pumps a little harder. If the clog doesn’t clear, ClearVue™ goes into a cleaning cycle and pulses the discharge water to try to dislodge the clog.
  • Page 6 ™...
  • Page 9 CHECK FOR SHIPMENT DAMAGE...
  • Page 13 Variable Li ClearVue™ pump features variable speed and lift. ClearVue™ pumps only as hard as it needs to, in a given installation, to lift the condensate water away. The lower the lift, the slower the pump runs, and the quieter the operation.
  • Page 14 Button Function Manually test motor operation Manually drain water from pump Run a clean cycle Activate or deactivate the audible alarm Silence the audible alarm (when enabled)
  • Page 15 Status LED Indicator Light Solid Green LED Solid Amber LED Solid Amber LED & Flashing Red LED Solid Amber LED & Flashing Red LED & Flashing White LED Flashing White LED Flashing White LED & Solid Amber LED Flashing Blue LED Indicates that pump sensors are operational.
  • Page 16 Symptom Possible Condition...
  • Page 17 Corrective Action...
  • Page 18 120 Volt version 120 Volts / 60 Hz Rated Voltage 1.9 Amps Rated Current Draw USA 3-prong plug Input Type 22 ft. maximum Head Height 1.6 GPM Flow Rate at Zero Head 500mL/min Maximum Rated Inlet Flow Rate ˚ Temperature Rating emperature 160F˚...
  • Page 20 The company maintains manufacturing and distribution facilities in key U.S. locations, Europe, and in the Far East. DiversiTech has enjoyed a continued history of successful growth and has acquired industry-recognized names including Devco® Enterprises, Wagner® Manufacturing, The Black Pad®, Hef-T-Pad™, and Specialty Chemical.

Table of Contents