RoMedic ReTurn 7500 Manual

Advertisement

Manual
Max: 150 kg/330 lbs
ReTurn7400
ReTurn7500
ReTurn7500 and ReTurn7400 are used indoors for shorter transfers between wheelchair and bed, wheelchair and toilet/
portable toilet/wheelchair or chair/armchair. ReTurn7500 and ReTurn7400 can also be used to aid repositioning farther
back in the chair. Both models are designed for easy manoeuvring and use in confined spaces. They are easy to assemble
and disassemble in just two sections for easier transport and storage. ReTurn7400 is lower than ReTurn7500 and is
designed mainly for children and small adults.
ReTurn7500/ReTurn7400 is part of a series of different models of transfer assistive devices. The choice of model and mate-
rial is determined by the patient's functional capacity and the situations in which the product is to be used.
RoMedic's products together form the SystemRoMedic concept, which takes a holistic approach to patient transfers.
SystemRoMedic has four categories of transfers: transfer, positioning, support and lifting.
Functional inspection
Visual inspection
Check the condition and function of the product regularly. Check to ensure that material is free from damage. If there are
signs of wear, the product must be inspected and serviced.
Always read the instructions
Read instructions for all assistive devices used in connection with transfers.
To prevent discomfort, exercise care and caution when using the product.
The product should be inspected yearly, and otherwise as required, by a qualified technician. Service must be performed
by a qualified technician.
Manual no: 00840 Ver. 2 091021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReTurn 7500 and is the answer not in the manual?

Questions and answers

Summary of Contents for RoMedic ReTurn 7500

  • Page 1 RoMedic’s products together form the SystemRoMedic concept, which takes a holistic approach to patient transfers. SystemRoMedic has four categories of transfers: transfer, positioning, support and lifting.
  • Page 2 M A N U A L Special requirements and conditions • ReTurn is not intended for long transfers. •Return can only be used on flat floor. • The caregiver must always apply counter pressure when the patient is standing up, sitting down (1) and during the actual transfer (2).
  • Page 3 M A N U A L Chassis and placement of feet 1. The feet are placed one on either side, see foot markings on base plate. 2. The patient’s weight must be centred on the product’s support surface (all weight between the wheels);...
  • Page 4 M A N U A L Testing standing function ReTurn is ideal for testing a patient’s standing function in cases where there is uncer- tainty as to whether the patient is able to rise from a seated to a standing position. Training standing function ReTurn can be used to train the patient’s standing, sitting and sit-to-stand function.
  • Page 5 Two caregivers with ReTurnBelt The RoMedic ReTurnBelt allows different gripping alternatives, and helps and encour- ages the patient to lean forward. One caregiver helps the patient to lean forward and provides support during raising.
  • Page 6: Technical Specifications

    When in doubt, contact your RoMedic representative for product trials, advice or information. If you require additional information, contact your transfer specialist or our representative, or visit www.romedic.com. Make sure you always have the most recent version of the manual. Manuals are available for downloading from our website;...

This manual is also suitable for:

Return 7400

Table of Contents