We are unable to move the knob that controls the water temperature to the hottest level and don’t know how to open it to see if there is a soap residue build up

1 comments:
Mr. Anderson
March 17, 2025

To check for soap residue buildup if the temperature control knob is stuck, follow these steps:

1. Turn Off Water Supply – Ensure the water supply is turned off to avoid leaks.
2. Remove the Handle – If the knob is stuck, try loosening the set screw holding the handle in place.
3. Detach the Temperature Control Knob – Carefully pull off the knob after loosening the screw.
4. Inspect and Clean – Check the area for soap residue or mineral buildup. Use a suitable cleaner, avoiding acids like hydrochloric or phosphoric acid.
5. Reinstall the Knob – Once cleaned, reinstall the knob and tighten the screw.
6. Test the Functionality – Turn the water back on and check if the knob moves freely.

If the knob remains stuck, additional disassembly or professional assistance may be required.

This answer is automatically generated

Summary of Contents for Hans Grohe Showerpanel

  • Page 1 Installation Instructions / Warranty Interaktiv Showerpanel...
  • Page 2 -- see page 13. *Proaktiv showerpanels are sold without trim. Proaktiv showerpanel trim kits are sold separately. **Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. In...
  • Page 3: Tools Required

    Make sure that all parts are present and in good condition. If any part is missing or damaged, please contact Hansgrohe Customer Service before proceeding. Tools Required The following tools are suggested for installing the Interaktiv Showerpanel: Tape measure Level...
  • Page 4 Roughing-in This unit can be installed on a flat wall or in a 90 corner. Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner. Ensure that you have a minimum 83”...
  • Page 5 Installation -- Flat Wall Wrap the threads on the supply nipples with Teflon thread tape. Install the enclosed elbows so that the outlets face upwards. Measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/8”.
  • Page 6 Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting. Attach the seals to the side covers. Install the side covers. The pins on the covers must go into the grooves on the sides of the panel.
  • Page 7 Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel. Turn to page 11 to continue the installation.
  • Page 8 Installation in 90 Corner Wrap the threads on the nipples with Teflon thread tape. Install the enclosed elbows so that the outlets face upwards. In the corner, measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top mounting bracket.
  • Page 9 While a helper holds the panel, attach the supply hoses to the elbows with the compression fittings. Use two wrenches, as shown in the diagram, to prevent the supply hoses from twisting. Tighten the hex head cap screw on the top mounting bracket.
  • Page 10 Clip the side cover seals as shown in the diagram. Attach the side cover seals to the valve cover. Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel.
  • Page 11 Install the Handle Push the handle over the valve stem. Tighten the set screw on the bottom of the handle with a 3 mm Allen wrench. The set screw must engage the slot milled into the thermoelement. Install the Handshower Place a black rubber washer in the short hose end connector.
  • Page 12 Justify the Handle Turn the water on to the handshower. Turn the temperature control knob so that the indicator is next to the 100 marking. Turn the temperature control knob so that the water mea- sures 100 F on a thermom- eter.
  • Page 13 Set the High Temperature Limit Stop (optional) Loosen the set screw on the handle. Grasp the barrel on the cartridge and turn it counter- clockwise to turn on the handshower. Grasp the barrel and turn it clockwise to turn the water off.
  • Page 14 User Instructions - Showerpanel I Turn the temperature control knob clockwise to make the water cooler, counter-clockwise to make it warmer. The knob will stop at the 100 desired, push in on the knob, and continue turning it counter-clockwise. From the “off” position, turn the diverter handle counter-clockwise for the handshower.
  • Page 15 Scale Removal The Raindance Air 3-jet handshower incorporates the Rubit cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge. If scale deposits are noticed on the spray face, pour about 3/4”...
  • Page 16 Check Valve Maintenance The check valve should be removed and inspected yearly. If the check valve is damaged, it should be replaced. check valve Clean the Thermostatic Cartridge Filters A possible cause of lost pressure, especially if the pressure decreases as the temperature increases, is debris clogging the filter screens on the thermostatic cartridge.
  • Page 17 Replacement Parts slider hose shelf sleeve thermostat cartridge thermoelement, panel I thermoelement, panel II side cover valve cover, panel I valve cover, panel II escutcheon handshower Solaris Stratos Metro, Interaktiv S handle - Interaktiv S handle - Solaris handle - Stratos handle - Metro check valve tub spout (panel II only)
  • Page 18 Cleaning Recommendation for Hansgrohe Products Modern sanitary faucetry and shower fixtures consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain points when cleaning: Cleaning materials for faucets and shower products: Acids are necessary ingredients of cleaning materials for removing lime.
  • Page 19 Interaktiv and Retroaktiv products, and (ii) for 5 years, with respect to AXOR, ShowerPower and Pharo products. THIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR: Conditions, malfunctions or damage not resulting from defects in material or workmanship.
  • Page 20 Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 Tel. 770 360-9880 • Fax 770 360 9887 www.hansgrohe-USA.com...