Page 1
Multizone Controller System Installation Manual...
Page 2
Quick stops, excessive force and uneven surfaces may cause the appliance and cart combination to overturn. Russound CA4 System Installation Manual...
OVERVIEW Thank you for choosing the Russound CA4 controller amplifier to enhance The CA4 kit ships with a remote control (CA4-RC), wall port (CA4-WP), four ® your home with multiroom audio. CAT-5 cables, and four keypads (CA4-KP) for home audio one-touch control. The user can adjust the bass, treble, loudness, and volume from each keypad.
12VDC Trigger RJ-45 Expander Jack Power Cord Connection Audio Source inputs RS232 Connection Zone 4 Fixed RCA Output Mute Input Wall Port RJ-45 Connections Common IR Zone 4 Variable RCA Output Routed IR Outputs Rear Panel Russound CA4 System Installation Manual...
Either press the Source button to go to the next option or exit the User Menu by a 3-second press of the source button or a time-out. Bass Setting Mode Treble Setting Mode Russound CA4 System Installation Manual...
Volume control remains Power Source, Volume Up, Volume Down, or Power buttons will independent as well as zone ON and OFF. Only zones connected to the turn the keypad ON same controller can be source grouped. Russound CA4 System Installation Manual...
• A non-Master keypad cannot issue an All ON command. The source and volume buttons will blink three times to indicate an invalid command, and then will return the keypad to normal operation. Russound CA4 System Installation Manual...
(DISC can be learned in as a source control feature.) Zone Control DISC Note: All source setup and control is contained in the CA4-RC remote control. The CA4 controller does not require programming for the controller or for source setup. See Remote Control usage and programming information later in this manual.
SYSTEm CONFIGURATION Controller / Keypad Configuration The CA4 Wall Port jacks are located on the rear of the controller. These RJ-45 ports must be connected to the corresponding jacks on the wall port. Each keypad is then connected to the wall port.
Jumper OFF - Normal Mode Select Source Decrease Volume CAT-5 with RJ-45 IR Receiver termination to connect to the wall port Power and Red LED talkback CA4 Keypad (rear) CA4 Keypad (front) with Decora® Trim Plate Russound CA4 System Installation Manual...
RJ-45 Connections Speaker terminals Use included CAT-5 cables to connect Four pair 8 ohm speakers the controller to the Wall Port. Two channels each CA4 Wall Port (front) CA4 Wall Port (rear) Russound CA4 System Installation Manual...
Speaker Outputs Pick an unobtrusive location close to the controller that all cables (speaker The CA4 supports speaker outputs for zones 1 through 4 for each controller and keypad) can be routed to. with a maximum of eight zones. Each speaker connection requires a 8-ohm load and will provide 15 watts per channel.
To install a single-gang keypad, you will need to use a UL/CSA approved plastic single-gang (18 ci) electrical box. Route CAT-5 wire to the electrical box from the CA4 Wall Port and label it with the zone number. Terminate the CAT-5 wire with a RJ-45 plug using the T568A standard configuration.
CONTROLLER CONNECTIONS Zone 4 Fixed/Variable Audio Output The CA4 has two line Audio outputs on Zone 4. These zone audio output connections feature a stereo line out RCA connection for a fixed and/or a variable line level output. When connected to Variable, the keypad volume level affects this output. In the Fixed position, the keypad volume level will not change the output level.
Mute In jacks so all zones will be muted. turned off. Note: The CA4 will not accept a paging audio input; however, if used with an independent paging system with 12VDC trigger out, that can be used to trigger the mute.
The CA4 supports RS-232 communication with various third party automation systems or PC for control, and potential firmware updates of the controller. The RS-232 port is located on the rear of the CA4 and uses a DB-9 cable connection. Directions will accompany any firmware updates.
Linking Two Controllers Connect the audio from the sources (up to four) to both controllers. The audio Two CA4 controllers can be linked together for a system that supports eight zones and four sources. This setup requires two controllers, a CAT-5 linking must be split using RCA “Y"...
CONTROLLER CONNECTIONS Source Audio Connections The CA4 supports up to four audio sources. The Source Inputs are located on the rear panel. Connect each source using quality RCA signal cables. Connect the Left and Right Audio outputs from each source to the corresponding inputs on the CA4 controller.
Check operation of all keypad functions. Treble, bass, loudness, source grouping, and All ON participation can be programmed at each keypad. Check for functional IR signal pass-through (if applicable). The system is now ready to use. Russound CA4 System Installation Manual...
If the device does not respond to the remote after trying all codes listed for your brand, auxiliary devices with the CA4-RC you need to program the remote. You will need to or if the brand is not listed, try searching for the code: install the batteries and have enough room to point the CA4-RC at the various source Press a source key once.
Page 23
Using Learning Mode Deleting a single learning key The CA4-RC includes a learning feature so you can add functions that are unique to your Press and hold SET until the LED flashes twice. home entertainment devices (i.e., VCR tracking up or down). The following precautions Press SET, then 9-7-6 to delete a learned function.
Speaker Cables: 14-18 gauge - screw termination Max cable length: Wall Port to controller 6' (2m) Wall Port to keypad 240' (73.2m) Wall Port to speaker 240' (73.2m) **Speaker connections are to the Wall Port, not to the controller. Russound CA4 System Installation Manual...
WARRANTY Warranty Before returning a unit for repair, call Russound at (603) 659-5170 for a Return The Russound CA4 controller, and CA4-WP wall port are fully guaranteed Authorization number. Write this number on the shipping label and ship to: against all defects in materials and workmanship for two (2) years from the date of purchase.
Need help?
Do you have a question about the CA4 and is the answer not in the manual?