PRESS 0 - DIAGNOSTICS MODE
.
PRESS 0 THEN 1 - VENDOR SELF-DIAGNOSTIC TEST
This menu is used to
perform a vendor self-
diagnostics test. Monitor
the display for possible
error messages. Record
errors
as
they
are
displayed.
Displayed Error
E## or ESc oPEn
(displayed when
entering Service Mode)
Ctl
ChSu
Cn
biLL
(when installed -
option)
rdr1
(when installed -
option)
tS1C
tS1o
22
STEP
1. Press Service Mode Button
Press
2.
Press
to start test
3.
Press
repeatedly to exit.
Possible Error Codes
Description
Selection Motor Diagnostic
##
= motor that has failed or
ESc oPEn - Coin Return Motor failed
Control Board input Error
Good or
Sl (keypad stuck)
Control board checksum error
Good or Fail
Coin Mechanism Diagnostic
Good or
Chg3 (communication error)
Bill Validator Diagnostic
Good or
Bil7 (communication error)
Card Reader Diagnostic
Good or
rdr8 (communication error)
The temperature sensor or harness is
considered to have an electrical short.
The temperature sensor or harness is
considered to have an open electrical
connection
DISPLAY
38 (Motor Count is displayed)
tESt
(test start)
E##
(failed motor(s))
CtL
(control board test)
ChSu (check sum control board test)
Cn
(Coin Mechanism test)
biLL (bill validator test - (when installed - option)
rdr1 (card reader test - (when installed - option)
(Sales Mode)
Possible Remedy
Check motor connection, test vend
Keypad stuck error: check keypad
connection, test all buttons, replace
Upon Fail turn power off ... wait 30
seconds and turn power back on ...
continues to Fail - replace control board
turn power off ... check coin mechanism
connection ... wait 30 seconds and turn
power back on ... continues to display
Chg3 - replace coin mechanism
turn power off ... check bill validator
connection ... wait 30 seconds and turn
power back on ... continues to display
Bil7 - replace bill validator
turn power off ... check card reader
connection ... wait 30 seconds and turn
power back on ... continues to display
rdr8 - replace card reader
Check sensor and sensor harness for
shorted condition.
Check for sensor readings.
Replace sensor if necessary
Check sensor and sensor harness for
open connections.
Check for sensor readings.
Replace sensor if necessary
4 2 2 3 0 7 4 . 0 0 1 F u t u r a S e r v i c e M a n u a l R E V A
dIAG
motor
keypad

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3589 and is the answer not in the manual?

Questions and answers

Paul Dupey
February 22, 2025

coins flow through to the change box. But dollar bills work.

1 comments:
Mr. Anderson
February 22, 2025

The coin mechanism of the Futura 3589 must be loaded with a minimum of one roll each of nickels, dimes, and quarters for proper operation. If the coin tubes are empty or not sufficiently filled, coins will not flow through to the change box, preventing the machine from giving change. Dollar bills, however, are accepted and processed separately by the bill validator, which does not rely on the coin tubes for operation.

This answer is automatically generated