Change The Oil - Xylem Flygt 3201 Installation Operation & Maintenance

Table of Contents

Advertisement

1
Torque,
70 +80
1.2 (0.9)
Nm (ft-lbs)
Carbon steel and alloyed steel
Torque,
8.8
2.3 (1.7)
Nm (ft-lbs)
10.9
3.2 (2.4)
12.9
3.9 (2.9)

Change the oil

The following items are needed for this procedure:
• New oil plugs
• New O-rings
• Oil drainage pump 83 95 42 or equivalent
• Oil
Oil type
Medical white oil of paraffin type
that fulfills FDA 172.878 (a)
1. Unscrew the oil plug.
The plug is marked "oil out".
1.
2.
2. Drain the pump.
Use the oil drainage pump. Make sure that the plastic tube goes all the way to the
bottom of the oil housing.
3. Fill the housing with new oil.
Flygt 3201 Installation, Operation, and Maintenance Manual
2.7 (2)
5.4 (4)
9.3 (6.9)
4.6 (3.4)
7.8 (5.8)
19 (14)
6.5 (4.8)
11(8)
26 (19)
7.8 (5.8)
14 (10.3)
32 (23.6)
Viscosity
ISO VG32
WARNING:
The oil housing may be pressurized. Hold a rag over the oil plug to
prevent oil from spraying out.
Inspection plug
Oil plug
22 (16)
44 (32)
76 (56)
38 (28)
65 (48)
158 (116)
52 (38)
91 (67)
222 (164)
63 (46)
109 (80)
266 (196)
Amount
7.5 liters (7.92 US quarts)
Maintenance
120 (88)
187 (138)
308 (228)
532 (392)
433 (320)
748 (552)
519 (383)
896 (661)
33