1-second UPS (persistent data)
8.1
BIOS settings
The CX51x0 family features a built-in capacitive one-second UPS. It ensures a safe storage of the persistent
application data on the Compact Flash card.
Up to 1 MB of persistent data can be saved. The UPS can be switched on and off via the BIOS. Under the
menu:
Advanced -> Power Controller Options
the parameter of the S-UPS are displayed and can be modified, if required.
Aptio Setup Utility - Copyright (C) American Megatrends, Inc.
Bootloader version
Firmware version
Mainboard serial no
Mainboard Prod. date (Week.Year) 44.14
Mainboard BootCount
Mainboard operation time
Voltage (Min/Max)
Temperature (Min/Max)
USB-Port voltage
WatchDogTimerMode
1-second Uninterruptable Power Supply (SUPS)
SUPS Enable
Hold Usb
Delay
SUPS Firmware version
Current Power source
Battery load level
Powerfail counter
Version 2.17.1246. Copyright (C) 2014 American Megatrends, Inc.
SUPS Enable
Options: Enable / Disable
Switches the SUPS on or off.
64
1.00-23
1.00-77
120003414250178
4711
1224min (20h)
5.00V / 5.20V
15°C / 63°C
[Off in S3-5]
[Compatibility mode]
[Enable]
[Enable]
0
1.09
On Line
100%
42
Version: 1.9
WatchDogTimer mode
→ ←: Select Screen
↑ ↓: Select Item
Enter: Select
+/-: Change Options
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Quit
CX51x0
Need help?
Do you have a question about the CX5120 and is the answer not in the manual?
Questions and answers