Drive Medical Pure Expressions RTLBP1000 Instruction Manual
Drive Medical Pure Expressions RTLBP1000 Instruction Manual

Drive Medical Pure Expressions RTLBP1000 Instruction Manual

Single channel electric breast pump

Advertisement

Quick Links

Item # RTLBP1000
I N S T R U C T I O N
M A N U A L
P ure
expressions
S I N G L E C H A N N E L
E L E C T R I C B R E A S T P U M P
SUCTION
SPEED
STIMULATION
EXPRESSION
min

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pure Expressions RTLBP1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Drive Medical Pure Expressions RTLBP1000

  • Page 1 P ure expressions ™ S I N G L E C H A N N E L E L E C T R I C B R E A S T P U M P SUCTION SPEED STIMULATION EXPRESSION Item # RTLBP1000 I N S T R U C T I O N M A N U A L...
  • Page 3: Indications For Use

    Congratulations on your new bundle of joy! Thank you for choosing the Pure Expressions Single Channel Electric Breast Pump. It has been known that the breast milk is the best natural food for your baby. With our collaboration with the breastfeeding experts and research with the lovely breastfeeding mothers who are determined to give the best to their babies, just like you, our products fulfill the breastfeeding mother’s needs...
  • Page 4: Warnings And Precautions

    • AC/DC Adapter • 4 AA Alkaline batteries • With bottle adaptor, transferable for wide or standard neck bottle • LCD Display shows the working state. • All parts that have direct contact with the milk and breast are BPA free. Warnings and Precautions Basic safety precautions should be taken when using electrical products, especially around children.
  • Page 5 not recommended by the manufacturer. • Keep cord away from heated surface. • Never use while sleepy or drowsy. • Never drop or insert objects into any opening or tubing. • Do not use outdoors or operate where aerosol products are being used, or where oxygen is being administered.
  • Page 6 Pure Expressions breast pump. • Pump only with the breast pump in the upright position. • DO NOT shorten the tubing. • Make sure the voltage of the power adapter is compatible with the power source. • Plug the adapter into the breast pump first, then into the power source.
  • Page 7 PARTS GUIDE 01 Dust Cover x 1 12 Pump unit x 1 02 Silicone Cushion x 1 13 Membrane x 1 03 Breast Shield body x 1 14 Valve Body x 1 04 Cap Plug x 1 15 Bottle Stand x 1 05 Cap x 1 16 Wide Neck Bottle 4oz x 1 06 Seal Ring x 1...
  • Page 8 Additional Accessories and Parts sold separately: BP001 Breast Pump Carry Bag BP002 Insulated Cooler Bag BP004 6oz wide neck storage bottle with cap BP005 27MM Pump Kit w/out Insert BP006 24MM Silicone Insert BP007 Valve Set - pair w/membrane BP008 Membrane (4pcs per bag) BP009 Tubing set (2pcs)
  • Page 9: How To Assemble The Expression Collection Kit

    How to assemble the Expression collection Kit The electric breast pump comes pre-assembled; however you need to re-assemble it after each cleaning. Before assembling, the parts that come in contact with breast milk directly, including the milk bottle, silicone cushion, breast shield body, membrane, valve, grid, damper, bottle cap, disc collar (if use standard bottle), should be cleaned and sterilized each time.
  • Page 10 2. Assembling the Cap Combo Make sure the Cap Plug 04 is plugged into the hole of the Cap 05 and the ensure it is tightened securely. Place the Damper 07 onto the Grid 08 and then place Cap 05 onto it to form a complete (b) Cap Combo.
  • Page 11 4. Assembling the Bottle and Bottle Stand Screw the bottle into the connector at the Breast Shield Body and place it on the Bottle Stand. Take off the Dust Cover when ready to pump. Connecting Expression collection Kit and Pump unit 1.
  • Page 12 3. Using 4AA alkaline batteries (not included). • Always replace all 4 AA Batteries at the same time. • Remove all batteries if you are not going to use the breast pump for a period of time. • Properly dispose of all batteries, according to regulations for environmental protection and recycling.
  • Page 13 Pumping Instructions 1. Control Panel Description 1. Place the breast shield over your breast so that your nipple is properly centered in the tunnel. 2. Take care not to kink the Tubing while pumping. 3. While the pump unit is connected to power source, press the On/Off Button to switch on the device.
  • Page 14 6. Press the Phase Button to toggle between stimulation and expression. 7. To adjust the suction level to your comfort during pumping, press the increase “+” button to increase suction or the “–“ button to decrease suction. • In Expression Phase, the vacuum can be adjusted to the desired level.
  • Page 15: Cleaning Instructions

    Cleaning Instructions: Follow these cleaning and sanitizing instructions unless you are told otherwise by your healthcare provider. Basic Cleaning Method • Rinse each piece that comes into contact with the body and or milk with cool water immediately after pumping. •...
  • Page 16 Cleaning the Electrical Pump Unit: • Electrical units, which house the motor and batteries, should be wiped with a clean paper towel or soft cloth after each use. • The electrical unit should never be put into water or other liquids for cleaning.
  • Page 17 Guidelines for Storing and Thawing Breast milk You should store and thaw your breast milk correctly. This is the only way you can be sure that all the important nutrients are preserved and bacterial contamination is minimized. Check with your hospital for specific instructions. Breast Milk Storage (For Healthy Term Babies)* Freshly Expressed Thawed Breast Milk...
  • Page 18: Troubleshooting

    Tips for Freezing/Thawing Breast Milk: • Do not refreeze breast milk after thawing. • Never fill bottles/bags more than 3/4 to allow space for expansion. • Label the bottle/bag with the date you expressed the milk. • Do not store breast milk in the door of the refrigerator, store in the back of the main body of the refrigerator to avoid fluctuations in temperature.
  • Page 19: Technical Data

    Tubing if there is something small inside, and make the Tubing dry before using. • Make sure the Cap Plug is installed correctly. • Make sure the Seal Ring is assembled. 3. No suction • Replace the distorted membrane for a new one. •...
  • Page 20 Refer to instruction manual / booklet Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Manufactured For: Medical Depot (dba Drive Medical) 99 Seaview Blvd. Port Washington, NY11050 (877) 224-0946 www.drivemedical.com...
  • Page 21 Attention: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
  • Page 22: Warranty Information

    LIMITED IN DURATION TO A PERIOD OF 120 DAYS FROM THE DATE OF PURCHASE BY THE ORIGINAL PURCHASER. In the event that this product if found by Drive Medical to not meet the above limited warranty, as purchaser's sole and exclusive...
  • Page 23 TO THE EXTENT PERMITTED BY LAW, DRIVE MEDICAL SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, REPLACEMENT COSTS RESULTING FROM THE BREACH OF ANY WRITTEN OR IMPLIED WARRANTY. If you wish to make a claim under this warranty, you will need the following: •...
  • Page 26 E L E C T R I C B R E A S T P U M P Manufactured for: ©2017, Medical Depot Inc., DBA Drive Medical Design and Manufacturing 99 Seaview Blvd., Port Washington, NY 11050 All Rights Reserved. Made in China.