Adam Equipment PMB 53 Manual

Adam Equipment PMB 53 Manual

Pmb moisture analyser
Hide thumbs Also See for PMB 53:

Advertisement

Adam Equipment
PMB Moisture Analyser
Software Version 1.44
Adam Equipment strives to be more environmentally focused and uses recycled materials and
environmentally friendly packaging where possible. As part of this initiative we have developed a short
form manual that uses less paper and ink to describe the main functions of your new Adam moisture
analyzer. A more detailed manual for this product, as well as manuals for all our current products, are
available at www.adamequipment.com. Thank you for your support of Adam Equipment and we hope
that you enjoy your new moisture analyzer.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PMB 53 and is the answer not in the manual?

Questions and answers

Summary of Contents for Adam Equipment PMB 53

  • Page 1 Adam moisture analyzer. A more detailed manual for this product, as well as manuals for all our current products, are available at www.adamequipment.com. Thank you for your support of Adam Equipment and we hope that you enjoy your new moisture analyzer.
  • Page 2 ©Adam Equipment 2017...
  • Page 3: Safety

    All repairs must be done by a trained technician. There are no user serviceable parts in the enclosure.  Contact Adam Equipment or your dealer for assistance or questions. HOT SURFACES  During test the cover of the heating chamber can become very hot, especially near the top vent.
  • Page 4: Table Of Contents

    8.0 SAMPLE PREPARATION ......................18 9.0 SPECIFICATIONS ......................... 20 You use this equipment at your own risk. Adam Equipment, its affiliates and partners will not be liable or responsible for any damage that arises to persons or property when using this moisture analyzer.
  • Page 5: Operation

    % moisture vs. dry weight =100 x ((initial mass - dry mass)/dry mass) Also called ATRO Moisture  % solid vs. dry weight = 100 x (initial mass/dry mass) Also called ATRO Solid ATRO Moisture or Solid tests are special applications specific to some industries. %Moisture and %Solid are the more common calculations. ©Adam Equipment 2017...
  • Page 6 Rapid – off means the function is disabled, on means it will Options: On, Off or manual (manual always work for every test and manual will ask the user each asks each time the user runs a test) time the test is run. ©Adam Equipment 2017...
  • Page 7 See the complete manual for information on Options are: comp, summ the different output settings. The user can print the current configuration by pressing the [Print] key during the process providing the second function for that key is not needed. ©Adam Equipment 2017...
  • Page 8: Running A Test

    Time Remaining for test if time limit set Stopping the Test During the test the user can stop the test at any time by pressing the [Start] key again. Otherwise it continues until the stop condition is met. ©Adam Equipment 2017...
  • Page 9 If the print test function is enabled in the test settings then the PMB will also store the results into one of 99 memories. See USING THE INTERNAL MEMORY SETTING To return to normal weighing press the [Tare] key. ©Adam Equipment 2017...
  • Page 10: Using The Internal Memory Setting

    Up to 10 characters can be used to describe the test. Press [Setup/Enter] at any time to finish the description. If no name is added the field will be shown as blanks when the name is shown during the recalling process. PST NAME BREAD-4 ©Adam Equipment 2017...
  • Page 11: Recall Test Settings

    The PMB is capable of holding up to 99 test results. If the analyzer memory is full the display will MEM FULL show a message. Delete some of the stored results to make room for new test results. 3.6 RECALLING TEST RESULTS During normal weighing mode press the [Dspl] key. The display shows: PRINT ©Adam Equipment 2017...
  • Page 12: Deleting Test Results

    [Setup/Enter] key to delete just this file. The display will show then the next available file. Press [Setup/Enter] to delete this file if desired. Pressing [Tare] will return the analyzer to normal operation. ©Adam Equipment 2017...
  • Page 13: Communication / Interfaces

    To load this file press the [Setup/Enter] key again. Or to choose a different file press the [Dspl] key to advance through the other available files, then press the [Setup/Enter] key when the desired file is shown. ©Adam Equipment 2017...
  • Page 14: Storing Results In Usb Memory

    USB memory. The file names will be the same as those used to store internally. Once the file has been saved the display will show for 2 seconds, then return to the USB display. STORE OK CONFIG Ld ©Adam Equipment 2017...
  • Page 15: Store And Recall Configuration Setting From Usb Memory

    Press the [Setup/Enter] key to enter the test load function. The display will show the file name of the first file found config1 To load this file press the [Setup/Enter] key again. Or to choose a different file press the [Dspl] key to advance through the other available files. config1 LOAD ©Adam Equipment 2017...
  • Page 16: Serial Interface

    NONE (=8N1), EVEN (=8E1) or ODD (=8 O 1) All lines are terminated with carriage return and line feed (<CR><LF>). In continuous output mode, the serial output format will be a single line in the form “12.567 g<CR><LF>”. ©Adam Equipment 2017...
  • Page 17: Menu Structure

    5.0 MENU STRUCTURE ©Adam Equipment 2017...
  • Page 18: Calibration

    It is possible to calibrate both the weighing results and temperature sensor. The mass calibration allows you to calibrate with 20g or 50g for the PMB 53, 100g or 150g for the PMB 163, and 100g or 200g for the PMB 202. Although the analyzer is calibrated at the factory prior to shipping it is recommended that you calibrate the moisture analyzer regularly for optimum performance.
  • Page 19: Sample Preparation

    Some plastics also are not suitable for this type of method due to the very low percent moisture and the heat required to extract this moisture. ©Adam Equipment 2017...
  • Page 20 10-14 WET APPLE 5-10 WHITE GLUE 54.3 YOGHURT 86.5 4.5-6.5 This list will be extended as information becomes available. If you wish to supply any information that may help others, please contact Adam Equipment or your dealer. ©Adam Equipment 2017...
  • Page 21: Specifications

    9.0 SPECIFICATIONS PMB 53 PMB 163 PMB 202 160 g Capacity 50 g 200 g Readability (S.D) +/- 0.001g / 0.01% 0.01g / 0.05% Repeatability weighing (S.D) +/- 0.002 g 0.02g Stabilisation Time Weighing Typically 3 sec. Suggested Minimum Sample size...
  • Page 22: Adam Equipment

    As  we  often  update  adaptor  products  to  meet  changing  legislation  it  is  not  possible  to  refer  to  the  exact  model  in  this  manual.  Please  contact  us  if  you  need  specifications  or  safety  information  for  your  particular  item. Do not attempt to connect or use an adaptor not supplied by us.      ©Adam Equipment 2017...
  • Page 23 Western Australia  Wuhan Economic & Technological  Republic of South Africa    Development Zone       430056 Wuhan       P.R.China   Phone +27 (0)11 974 9745  Phone: +61 (0) 8 6461 6236  Phone: + 86 (27) 59420391  Fax:  +27 (0)11 392 2587  Fax +61 (0) 8 9456 4462  Fax + 86 (27) 59420388  e‐mail: sales@adamequipment.co.za  e‐mail: sales@adamequipment.com.au  e‐mail: info@adamequipment.com.cn          © Copyright by Adam Equipment Co.  All rights reserved.  No part of this publication may be reprinted or translated  in any form or by any means without the prior permission of Adam Equipment.    Adam Equipment reserves the right to make changes to the technology, features, specifications and design of the  equipment without notice.    All information contained within this publication is to the best of our knowledge timely, complete and accurate  when issued.  However, we are not responsible for misinterpretations which may result from the reading of this  material.    The latest version of this publication can be found on our Website.    www.adamequipment.com  ©Adam Equipment 2017...

This manual is also suitable for:

Pmb 163Pmb 202

Table of Contents

Save PDF