4. wIRINg DIAgRAMS:
4.1 INDESIT ELECTROMEChANICAL VENTED MODELS
SwITCh RATINgS REVERSINg TIMERS
Type
PEAPSA
Invensys ZBN
Invensys EC
Elbi 5000
PEAPSA
Invensys ZBN
Invensys EC
Elbi 5000
PEAPSA
Invensys ZBN
Invensys EC
Elbi 5000
MAIN TIMER SEqUENCE REVERSINg TIMERS
Timer Markings
Actual time
switch
no.
switch
1
2
3
4
timer motor
2 - 1
heater
1 -10
switch
no.
switch
1
2
3
4
15s
*2
motor cw
4 - 3
Service Manual
Yate Production Dryers
CONTACT /
TERMINAL
2 - 1
2 - 1
B1 - B3
B5 - B3
1 - 10
1 - 10
A9/A10 - A11
A3 - A2
4 - 3,5
4 - 3,5
B9/B10 - B11, B12
C3 - C1, C2
PROGRAMME CAM
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58
Note *1 the programme cam must advance to step 1 before stopping
REVERSING CAM
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58
15s
1.5s ± 0.5
RATINg
COMPONENT
SwITChED
16 (4) A
MOTOR &
HEATER
16 (4) A
HEATER
16 (4) A
MOTOR (Reversing)
149 s ± 2.5
Edition
2006.09.21
E
MAX.
CURRENT
12 A
12 A
< 2 A
1.5s ± 0.5
Language
English