Page
8
Kundendienst
Section
2.2.2
Fault
descriptions
TNC 150
VDU Display
(flashing)
X-MEASURING
SYSTEM DEFECTIVE
Y-MEASURING
SYSTEM DEFECTIVE
Z-MEASURING
SYSTEM DEFECTIVE
AXIS
4 MEAS.
SYSTEM DEFECTIVE
RELAY
EXT.
DC VOLTAGE
MISSING
EMERGENCY STOP DEFECTIVE
WRONG REFERENCE
POINT
SWITCH
POWER OFF,
THEN
ON
AGAIN
Fault
cause
.Measuring
system
not
connected
.C&le
damaged
.Glass
scale
dirty
or
damaged
.Scanning
head
damaged
.Measuring
system
supervision
damaged
.Machine
voltage
(+24V)
missing
(for
checking
routine,
see
Mounting
Instructions
and
Interface
Circuit
Control-Machine
manual
TNC 150 B/
TNC 150 Q page
19 and
20)
.Supervision
circuit
defective
.Fault
in
the
emergency
stop
circuit
of
the
machine
(for
checking
routine
see
Mounting
Instructions
and
Interface
Circuit
Control-Machine
manual
TNC 150 B/TNC
150 Q page
19/20)
Defect
in
Control's
internal
Emergency
Stop
supervision
.Traversed-over
reference
point
lies
outside
the
reference
point
end-pos-
ition
(also
see
Mounting
Instructions
and
Interface
Circuit
Control
Machine
TNC 150 B/TNC
150 Q, pg.20.21.22
.Defect
in
Control/machine
interface
Changing
of
machine
parameters
12,13,
14,15,60,72,90,170
during
operation
Possible
fault
location
Measuring
system
Analogue
Board
PLC I/O
Board
(TNC 150 P/Q)
PLC Interface
Board
(TNC 150 P/Q)
SE Board
(TNC 150 A/B)
Terminal
Board
(TNC 150 A/B)
Analogue
Board
PIC
I/O
Board
ONC
150 P/Q)
PLC Interface
Boaid
(TNC 150 P/Q)
SE Board
(TNC 150 A/B)
Teminal
Board
U-NC 150 A/B)
kchine
(cams/switches
"reference
end position"
or
"&&fere&
pulse
inhibit")
PLC I/O
Board
(TNC 150 P/Q)
PLC Interface
Board
(TNC 150 P/Q)
SE Board
VTNC 150 A/B)
Terminal
Board
YlYNC 150 A/B)