6.3.5
Scanner related adjustment
[A] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON (Adjustment Mode)
(2)
Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3)
[SETTINGS] [USER FUNCTIONS] Select [DRAWER] Select [DRAWER1]
Set the paper size to A3/LD. [OK] Set A3/LD for the paper in upper drawer.
(4)
[CANCEL] [CANCEL] Select the upper drawer by pressing [DRAWER]. Press [START]
to make copies.
(5)
Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(6)
Check if the distance A is within the range of 260±0.5 mm.
(7)
If not, use the following procedure to change values and measure the distance A again.
[SETTINGS] (Key in the code [4000]) [START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
[SETTINGS] Select the upper drawer by pressing [DRAWER]. Press [START] to make
copies.
* The larger the adjustment value is, the higher the reproduction ratio and the longer the
distance A become (approx. 0.15 mm/step).
Copied image of the ruler
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Feeding direction
Fig.6-9
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
6 - 15
SETTING / ADJUSTMENT